CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI is a 295.0 W STC (264.0 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.02% efficiency, 44.7 V Voc at 25 C, and 50.16 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 264.0 W

- **Voc @ 25C** : 44.7 V

- **Efficiency** : 18.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI (Multi-c-Si) residential solar systems.

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI delivers 180.2 W/m2 (1.89 percentage points below 19.91% CEC median) and typical 89.5% PTC-to-STC thermal output (264.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (493 sq ft). At -4 F (-20 C), string voltage climbs to 51.72 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with BYD Company Limited BYD295P6K-36 (295.0 W).

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI across nameplate watts, 89.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,068

### 18.02% Aperture Efficiency

Power density 180.2 W/m2 (1.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.16 V at -10 C (551.8 V string) and 51.72 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 45.8 m2 (493 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.7 * (1 + (-0.349/100) * (-10 - 25)) = 50.16 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI: Voc=44.7 V, beta_Voc=-0.349%/C, Isc=8.6 A, STC=295.0 W, Area=1.637 m2.

**Result:** 11 panels max on 600 V (551.8 V); 28 panels for 8 kW (493 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI including Isc (8.6 A), Voc (44.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 264.0 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.6 V / 8.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.349 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.02% (1.637 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 370 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 493 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 599 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M290TI** | 290.0 W | 259.3 W | 44.5 V | 35.4 V | 17.72% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI** | 295.0 W | 264.0 W | 44.7 V | 35.6 V | 18.02% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI (44.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.7V and beta_Voc=-0.349%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.72 V | 11 panels | 568.9 V | 19 panels |
| **-10 C (14 F)** | 50.16 V | 11 panels | 551.8 V | 19 panels |
| **0 C (32 F)** | 48.6 V | 12 panels | 583.2 V | 20 panels |
| **25 C (77 F STC)** | 44.7 V | 13 panels | 581.1 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI?

Four comparable CEC modules such as BYD Company Limited BYD295P6K-36 (295.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**BYD Company Limited BYD295P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd295p6k-36/) BYD Company Limited | 295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| [**Chinaland Solar Energy HSE295-72M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72m/) Chinaland Solar Energy | 295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
| [**Centrosolar America TP7 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| [**Centrosolar America TP7S 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7s-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI (295.0 W STC, 44.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI reaches 51.72 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 493 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (493 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI 8 kW Residential Fit

Needs 28 modules (493 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 264.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI cold Voc rises from 44.7 V to 50.16 V (beta_Voc -0.349%/C), capping a 600 V string at 11 panels (551.8 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI need?

An 8 kW DC system uses 28 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI modules (8,260 W STC / 7,392 W PTC), covering roughly 493 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI compare against BYD Company Limited BYD295P6K-36?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI outputs 295.0 W STC (44.7 V Voc, rank #16,890 of 21,677), while BYD Company Limited BYD295P6K-36 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, BYD Company Limited BYD295P6K-36 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)