title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (295.0W, 44.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-m295ri/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI: 295.0W STC, 44.7V Voc, 28-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI is a 295.0 W STC (263.3 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.08% efficiency, 44.7 V Voc at 25 C, and 50.43 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 263.3 W

- **Voc @ 25C** : 44.7 V

- **Efficiency** : 15.08%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI (295.0 W STC) vs. BYD Company Limited BYD295P6K-36 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI pairs typical 89.3% PTC-to-STC thermal output (263.3 W real-world rating) with 44.7 V nominal Voc. An 8 kW residential build (8,260 W DC, 7,372 W PTC) saves ~$2,067/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer BYD Company Limited BYD295P6K-36 offers a 295.0 W alternative.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI at 295.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI on STC wattage, thermal PTC/STC retention, and 15.08 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,624

### 15.08% Aperture Efficiency

Power density 150.8 W/m2 (4.83 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.43 V at -10 C (554.7 V string) and 52.06 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 54.8 m2 (590 sq ft) producing 7,372 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.7 * (1 + (-0.366/100) * (-10 - 25)) = 50.43 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI: Voc=44.7 V, beta_Voc=-0.366%/C, Isc=8.6 A, STC=295.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (554.7 V); 28 panels for 8 kW (590 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 263.3 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.6 V / 8.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.366 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.08% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (590 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 442 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 590 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 716 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Sibling wattage bins and frame colors grouped with HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI under HYUNDAI ENERGY SOLUTIONS CO LTD to prevent duplicate spec pages.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M290RI** | 290.0 W | 258.7 W | 44.5 V | 35.4 V | 14.83% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI** | 295.0 W | 263.3 W | 44.7 V | 35.6 V | 15.08% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI (beta_Voc -0.366%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=44.7V and beta_Voc=-0.366%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.06 V | 11 panels | 572.7 V | 19 panels |
| **-10 C (14 F)** | 50.43 V | 11 panels | 554.7 V | 19 panels |
| **0 C (32 F)** | 48.79 V | 12 panels | 585.5 V | 20 panels |
| **25 C (77 F STC)** | 44.7 V | 13 panels | 581.1 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI matched near 295.0 W STC and 44.7 V Voc, led by BYD Company Limited BYD295P6K-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**BYD Company Limited BYD295P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd295p6k-36/) BYD Company Limited | 295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| [**Chinaland Solar Energy HSE295-72M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72m/) Chinaland Solar Energy | 295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
| [**Centrosolar America TP7 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| [**Centrosolar America TP7S 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7s-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI (295.0 W STC, 44.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI reaches 52.06 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (590 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI 8 kW Residential Fit

Needs 28 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 263.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI's 8.6 A short-circuit current by 1.56 equals 13.42 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.43 V cold Voc at 14 F and handles 8.6 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI at 11 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, BYD Company Limited BYD295P6K-36 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)