# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI is a 273.0 W STC (245.4 W PTC) Mono-c-Si solar module ranking #18,570 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 14.07% efficiency, 43.9 V Voc at 25 C, and 49.09 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 273.0 W

- **PTC Wattage** : 245.4 W

- **Voc @ 25C** : 43.9 V

- **Efficiency** : 14.07%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 273.0 W STC and 245.4 W PTC, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI sits -112.0 W vs all-CEC median (below all-CEC median; higher than 14.3% of peers) among 21,677 listed modules. Power density reaches 140.7 W/m2 (5.84 percentage points below 19.91% CEC median). Mid-range 43.9 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Centrosolar America DP72 270 rates 270.0 W.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI (273.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,570 / 21,677

### 273.0 W STC · Higher Than 14.3%

273.0 W STC (-112.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,842

### 14.07% Aperture Efficiency

Power density 140.7 W/m2 (5.84 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.09 V at -10 C (589.1 V string) and 50.58 V at -20 C (11 max).

 8 kW Reference Array

### 30 Panels = 8,190 W STC

Occupies 58.2 m2 (626 sq ft) producing 7,362 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.9 * (1 + (-0.338/100) * (-10 - 25)) = 49.09 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI: Voc=43.9 V, beta_Voc=-0.338%/C, Isc=8.2 A, STC=273.0 W, Area=1.94 m2.

**Result:** 12 panels max on 600 V (589.1 V); 30 panels for 8 kW (626 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 273.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 245.4 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.2 V / 7.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.338 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.07% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.01 kW | 459 sq ft | $1,504 | $2,544 |
| **8 kW Class** | 30 | 8.19 kW | 626 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 37 | 10.1 kW | 773 sq ft | $2,528 | $4,275 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI (49.09 V at 14 F).

Computed from Voc=43.9V and beta_Voc=-0.338%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.58 V | 11 panels | 556.4 V | 19 panels |
| **-10 C (14 F)** | 49.09 V | 12 panels | 589.1 V | 20 panels |
| **0 C (32 F)** | 47.61 V | 12 panels | 571.3 V | 21 panels |
| **25 C (77 F STC)** | 43.9 V | 13 panels | 570.7 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI in nameplate wattage and Voc, starting with Centrosolar America DP72 270.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DP72 270**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-270/) Centrosolar America | 270.0 W | -3.0 W | 43.85 V | 13.89% | 88.4% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM270-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm270-72/) Anhui Rinengzhongtian Semiconductor Development | 270.0 W | -3.0 W | 43.67 V | 13.92% | 89.6% |
| [**AXITEC AC-270P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-270p-156-72s/) AXITEC | 270.0 W | -3.0 W | 44.18 V | 13.94% | 89.9% |
| [**Advance Power API-M270**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m270/) Advance Power | 270.0 W | -3.0 W | 44.64 V | 13.84% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI (273.0 W STC, 43.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI reaches 50.58 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI 8 kW Residential Fit

Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 270.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 245.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI cold Voc rises from 43.9 V to 49.09 V (beta_Voc -0.338%/C), capping a 600 V string at 12 panels (589.1 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI need?

An 8 kW DC system uses 30 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI modules (8,190 W STC / 7,362 W PTC), covering roughly 626 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI compare against Centrosolar America DP72 270?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI outputs 273.0 W STC (43.9 V Voc, rank #18,570 of 21,677), while Centrosolar America DP72 270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Centrosolar America DP72 270 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)