title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (250.0W, 37.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-m250mg/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG: 250.0W STC, 37.6V Voc, 32-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG is a 250.0 W STC (226.1 W PTC) Multi-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.46% efficiency, 37.6 V Voc at 25 C, and 41.84 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 250.0 W

- **PTC Wattage** : 226.1 W

- **Voc @ 25C** : 37.6 V

- **Efficiency** : 15.46%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG (250.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6610P-250 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG pairs typical 90.4% PTC-to-STC thermal output (226.1 W real-world rating) with 37.6 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,235 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6610P-250 offers a 250.0 W alternative.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG at 250.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG on STC wattage, thermal PTC/STC retention, and 15.46 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #19,686 / 21,677

### 250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,977

### 15.46% Aperture Efficiency

Power density 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.84 V at -10 C (585.8 V string) and 43.05 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,000 W STC

Occupies 51.7 m2 (557 sq ft) producing 7,235 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.6 * (1 + (-0.322/100) * (-10 - 25)) = 41.84 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG: Voc=37.6 V, beta_Voc=-0.322%/C, Isc=8.6 A, STC=250.0 W, Area=1.617 m2.

**Result:** 14 panels max on 600 V (585.8 V); 32 panels for 8 kW (557 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 250.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 226.1 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.9 V / 8.1 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.322 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.46% (1.617 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (557 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.0 kW | 418 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 32 | 8.0 kW | 557 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 40 | 10.0 kW | 696 sq ft | $2,503 | $4,232 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG (beta_Voc -0.322%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.6V and beta_Voc=-0.322%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.05 V | 13 panels | 559.6 V | 23 panels |
| **-10 C (14 F)** | 41.84 V | 14 panels | 585.8 V | 23 panels |
| **0 C (32 F)** | 40.63 V | 14 panels | 568.8 V | 24 panels |
| **25 C (77 F STC)** | 37.6 V | 15 panels | 564.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG matched near 250.0 W STC and 37.6 V Voc, led by Boviet Solar Technology Co Ltd BVM6610P-250.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6610P-250**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610p-250/) Boviet Solar Technology Co Ltd | 250.0 W | Tie (0 W) | 37.5 V | 15.37% | 90.2% |
| [**Anji Technology AJP-M660-250**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-250/) Anji Technology | 250.0 W | Tie (0 W) | 37.32 V | 15.4% | 89.0% |
| [**Eoplly New Energy Technology EP156MB/60-250S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-250s-ac/) Eoplly New Energy Technology | 250.0 W | Tie (0 W) | 37.26 V | 15.45% | 89.6% |
| [**Changzhou Nesl Solartech DJ-250DA/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-250da-c-st15/) Changzhou Nesl Solartech | 250.0 W | Tie (0 W) | 38.07 V | 15.3% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG (250.0 W STC, 37.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG reaches 43.05 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (557 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG 8 kW Residential Fit

Needs 32 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610P-250.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG's 8.6 A short-circuit current by 1.56 equals 13.42 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.84 V cold Voc at 14 F and handles 8.6 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG at 14 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Boviet Solar Technology Co Ltd BVM6610P-250 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)