title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (240.0W, 37.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-m240rg-bk/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK): 240.0W STC, 37.1V Voc, 34-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) is a 240.0 W STC (216.0 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.66% efficiency, 37.1 V Voc at 25 C, and 41.19 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 216.0 W

- **Voc @ 25C** : 37.1 V

- **Efficiency** : 14.66%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) (Multi-c-Si) residential solar systems.

Homeowners evaluating HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) need 25 panels for 6 kW or 34 panels (599 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (599 sq ft). Under NEC 690.7(A), beta_Voc (-0.315%/C) pushes open-circuit voltage to 41.19 V at 14 F and 42.36 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,225

### 14.66% Aperture Efficiency

Power density 146.6 W/m2 (5.25 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.19 V at -10 C (576.7 V string) and 42.36 V at -20 C (14 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 55.7 m2 (599 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 13.1 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.1 * (1 + (-0.315/100) * (-10 - 25)) = 41.19 V | OCPD = 1.56 * 8.4 = 13.1 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK): Voc=37.1 V, beta_Voc=-0.315%/C, Isc=8.4 A, STC=240.0 W, Area=1.637 m2.

**Result:** 14 panels max on 600 V (576.7 V); 34 panels for 8 kW (599 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) including Isc (8.4 A), Voc (37.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 216.0 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.6 V / 7.9 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.315 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.66% (1.637 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 441 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 599 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 740 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M235RG(BK)** | 235.0 W | 211.4 W | 37.1 V | 30.5 V | 14.36% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)** | 240.0 W | 216.0 W | 37.1 V | 30.6 V | 14.66% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245RG(BK)** | 245.0 W | 220.7 W | 37.3 V | 30.7 V | 14.97% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) (37.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.1V and beta_Voc=-0.315%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.36 V | 14 panels | 593.0 V | 23 panels |
| **-10 C (14 F)** | 41.19 V | 14 panels | 576.7 V | 24 panels |
| **0 C (32 F)** | 40.02 V | 14 panels | 560.3 V | 24 panels |
| **25 C (77 F STC)** | 37.1 V | 16 panels | 593.6 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)?

Four comparable CEC modules such as Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T (240.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-0-240t/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.1 V | 14.53% | 88.9% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240TB**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-0-240tb/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.1 V | 14.53% | 90.0% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-0-240tw/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.1 V | 14.53% | 88.9% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240T**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-4-240t/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.1 V | 14.53% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) (240.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) reaches 42.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 599 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (599 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) 8 kW Residential Fit

Needs 34 modules (599 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 216.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) PTC wattage (216.0 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 216.0 W PTC (90.0% retention) across HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)'s 1.637 m2 aperture.

### Who should skip HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) panels (599 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T.

### What is the 1,000 V commercial string limit for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK)?

On 1,000 V commercial inverters at -10 C (41.19 V cold Voc), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK) fits up to 24 panels per series string.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK).

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)