---
title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs hyundai-energy #21"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-m238mg-bk/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK): 238.0W STC, 37.2V Voc, 34-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) is a 238.0 W STC (214.4 W PTC) Multi-c-Si solar module ranking #20,362 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.72% efficiency, 37.2 V Voc at 25 C, and 42.23 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 238.0 W

- **PTC Wattage** : 214.4 W

- **Voc @ 25C** : 37.2 V

- **Efficiency** : 14.72%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) (238.0 W STC) vs. CSI Solar Co Ltd CS6P-240M across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) pairs typical 90.1% PTC-to-STC thermal output (214.4 W real-world rating) with 37.2 V nominal Voc. An 8 kW residential build (8,092 W DC, 7,290 W PTC) saves ~$2,025/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS6P-240M offers a 240.0 W alternative.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) at 238.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) on STC wattage, thermal PTC/STC retention, and 14.72 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #20,362 / 21,677

### 238.0 W STC · Higher Than 6.1%

238.0 W STC (-147.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,142

### 14.72% Aperture Efficiency

Power density 147.2 W/m2 (5.19 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.23 V at -10 C (591.2 V string) and 43.66 V at -20 C (13 max).

 8 kW Reference Array

### 34 Panels = 8,092 W STC

Occupies 55.0 m2 (592 sq ft) producing 7,290 W PTC; NEC 690.8 OCPD floor is 12.95 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.2 * (1 + (-0.386/100) * (-10 - 25)) = 42.23 V | OCPD = 1.56 * 8.3 = 12.95 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK): Voc=37.2 V, beta_Voc=-0.386%/C, Isc=8.3 A, STC=238.0 W, Area=1.617 m2.

**Result:** 14 panels max on 600 V (591.2 V); 34 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 238.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 214.4 W (90.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.3 V / 7.9 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.386 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.72% (1.617 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (592 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.19 kW | 453 sq ft | $1,549 | $2,620 |
| **8 kW Class** | 34 | 8.09 kW | 592 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 43 | 10.23 kW | 748 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Sibling wattage bins and frame colors grouped with HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) under HYUNDAI ENERGY SOLUTIONS CO LTD to prevent duplicate spec pages.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M225MG(BK)** | 225.0 W | 202.4 W | 36.7 V | 30.1 V | 13.91% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M228MG(BK)** | 228.0 W | 205.2 W | 36.8 V | 30.1 V | 14.1% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M230MG(BK)** | 230.0 W | 207.0 W | 36.9 V | 30.1 V | 14.22% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M233MG(BK)** | 233.0 W | 209.8 W | 37.0 V | 30.2 V | 14.41% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M235MG(BK)** | 235.0 W | 211.6 W | 37.1 V | 30.3 V | 14.53% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)** | 238.0 W | 214.4 W | 37.2 V | 30.3 V | 14.72% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240MG(BK)** | 240.0 W | 216.3 W | 37.3 V | 30.5 V | 14.84% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M243MG(BK)** | 243.0 W | 219.0 W | 37.5 V | 30.6 V | 15.03% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245MG(BK)** | 245.0 W | 217.7 W | 38.0 V | 30.7 V | 15.15% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M248MG(BK)** | 248.0 W | 220.4 W | 38.0 V | 30.7 V | 15.34% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) (beta_Voc -0.386%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.2V and beta_Voc=-0.386%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.66 V | 13 panels | 567.6 V | 22 panels |
| **-10 C (14 F)** | 42.23 V | 14 panels | 591.2 V | 23 panels |
| **0 C (32 F)** | 40.79 V | 14 panels | 571.1 V | 24 panels |
| **25 C (77 F STC)** | 37.2 V | 16 panels | 595.2 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) matched near 238.0 W STC and 37.2 V Voc, led by CSI Solar Co Ltd CS6P-240M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6P-240M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-240m/) CSI Solar Co Ltd | 240.0 W | +2.0 W | 37.3 V | 15.5% | 90.5% |
| [**CSI Solar Co Ltd CS6P-240MX**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-240mx/) CSI Solar Co Ltd | 240.0 W | +2.0 W | 37.3 V | 15.5% | 88.3% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-2-240q/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | +2.0 W | 37.3 V | 14.53% | 89.0% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QB**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-2-240qb/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | +2.0 W | 37.3 V | 14.53% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) (238.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) reaches 43.66 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) 8 kW Residential Fit

Needs 34 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS6P-240M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK)'s 8.3 A short-circuit current by 1.56 equals 12.95 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.23 V cold Voc at 14 F and handles 8.3 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) at 14 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK) rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, CSI Solar Co Ltd CS6P-240M specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK).

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)
