title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (236.0W, 37.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-m236sg/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG: 236.0W STC, 37.6V Voc, 34-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG is a 236.0 W STC (205.2 W PTC) Multi-c-Si solar module ranking #20,366 of 21,677 CEC listings (below all-CEC median; higher than 6.0% of peers). It delivers 14.59% efficiency, 37.6 V Voc at 25 C, and 43.46 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 236.0 W

- **PTC Wattage** : 205.2 W

- **Voc @ 25C** : 37.6 V

- **Efficiency** : 14.59%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG (Multi-c-Si) residential solar systems.

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG delivers 145.9 W/m2 (5.32 percentage points below 19.91% CEC median) and typical 86.9% PTC-to-STC thermal output (205.2 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (592 sq ft). At -4 F (-20 C), string voltage climbs to 45.13 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Advance Power API-M235 (235.0 W).

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG (236.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG across nameplate watts, 86.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,366 / 21,677

### 236.0 W STC · Higher Than 6.0%

236.0 W STC (-149.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,296

### 14.59% Aperture Efficiency

Power density 145.9 W/m2 (5.32 percentage points below 19.91% CEC median). PTC/STC ratio: 86.9% (rank #21,600).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.46 V at -10 C (565.0 V string) and 45.13 V at -20 C (13 max).

 8 kW Reference Array

### 34 Panels = 8,024 W STC

Occupies 55.0 m2 (592 sq ft) producing 6,977 W PTC; NEC 690.8 OCPD floor is 12.95 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.6 * (1 + (-0.445/100) * (-10 - 25)) = 43.46 V | OCPD = 1.56 * 8.3 = 12.95 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG: Voc=37.6 V, beta_Voc=-0.445%/C, Isc=8.3 A, STC=236.0 W, Area=1.617 m2.

**Result:** 13 panels max on 600 V (565.0 V); 34 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG including Isc (8.3 A), Voc (37.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 236.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 205.2 W (86.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.9 V / 7.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.445 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.59% (1.617 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.14 kW | 453 sq ft | $1,537 | $2,599 |
| **8 kW Class** | 34 | 8.02 kW | 592 sq ft | $2,007 | $3,394 |
| **10 kW Class** | 43 | 10.15 kW | 748 sq ft | $2,540 | $4,296 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M227SG** | 227.0 W | 204.8 W | 37.2 V | 30.3 V | 14.04% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M230SG** | 230.0 W | 207.6 W | 37.2 V | 30.5 V | 14.22% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M233SG** | 233.0 W | 202.5 W | 37.5 V | 29.7 V | 14.41% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG** | 236.0 W | 205.2 W | 37.6 V | 29.9 V | 14.59% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M239SG** | 239.0 W | 207.9 W | 37.7 V | 30.0 V | 14.78% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M242SG** | 242.0 W | 210.6 W | 37.8 V | 30.2 V | 14.97% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG (37.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.6V and beta_Voc=-0.445%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.13 V | 13 panels | 586.7 V | 22 panels |
| **-10 C (14 F)** | 43.46 V | 13 panels | 565.0 V | 23 panels |
| **0 C (32 F)** | 41.78 V | 14 panels | 584.9 V | 23 panels |
| **25 C (77 F STC)** | 37.6 V | 15 panels | 564.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG?

Four comparable CEC modules such as Advance Power API-M235 (235.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-M235**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m235/) Advance Power | 235.0 W | -1.0 W | 37.5 V | 14.35% | 89.3% |
| [**Auxin Solar AXN6M610T235**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m610t235/) Auxin Solar | 235.0 W | -1.0 W | 37.5 V | 14.35% | 89.3% |
| [**APOS Energy AS235**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as235/) APOS Energy | 235.0 W | -1.0 W | 37.34 V | 14.17% | 89.7% |
| [**Gintech Energy GTE 235M**](https://epri-peac.com/solar-equipment/modules/gintech-energy/gintech-energy-gte-235m/) Gintech Energy | 235.0 W | -1.0 W | 37.32 V | 13.97% | 89.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG (236.0 W STC, 37.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG reaches 45.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG 8 kW Residential Fit

Needs 34 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-M235.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 205.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG cold Voc rises from 37.6 V to 43.46 V (beta_Voc -0.445%/C), capping a 600 V string at 13 panels (565.0 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG need?

An 8 kW DC system uses 34 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG modules (8,024 W STC / 6,977 W PTC), covering roughly 592 sq ft and saving ~$2,007/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG compare against Advance Power API-M235?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG outputs 236.0 W STC (37.6 V Voc, rank #20,366 of 21,677), while Advance Power API-M235 delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Advance Power API-M235 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)