title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (520.0W, 49.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI: 520.0W STC, 49.0V Voc, 16-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI is a 520.0 W STC (488.2 W PTC) Mono-c-Si solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 20.23% efficiency, 49.0 V Voc at 25 C, and 53.48 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 520.0 W

- **PTC Wattage** : 488.2 W

- **Voc @ 25C** : 49.0 V

- **Efficiency** : 20.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI (520.0 W STC) vs. Bila Solar Inc AA520US-6x24GG across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI pairs strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677) with 49.0 V nominal Voc. An 8 kW residential build (8,320 W DC, 7,811 W PTC) saves ~$2,082/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Bila Solar Inc AA520US-6x24GG offers a 520.0 W alternative.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI at 520.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI on STC wattage, thermal PTC/STC retention, and 20.23 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #4,199 / 21,677

### Top 19.9% STC Output

520.0 W STC (+135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,658

### 20.23% Aperture Efficiency

Power density 202.3 W/m2 (0.32 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.48 V at -10 C (588.3 V string) and 54.76 V at -20 C (10 max).

 8 kW Reference Array

### 16 Panels = 8,320 W STC

Occupies 41.1 m2 (443 sq ft) producing 7,811 W PTC; NEC 690.8 OCPD floor is 21.11 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.261/100) * (-10 - 25)) = 53.48 V | OCPD = 1.56 * 13.53 = 21.11 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI: Voc=49.0 V, beta_Voc=-0.261%/C, Isc=13.53 A, STC=520.0 W, Area=2.57 m2.

**Result:** 11 panels max on 600 V (588.3 V); 16 panels for 8 kW (443 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 488.2 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.7 V / 12.79 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.261 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.23% (2.57 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (443 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.24 kW | 332 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 16 | 8.32 kW | 443 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 20 | 10.4 kW | 553 sq ft | $2,603 | $4,402 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI (beta_Voc -0.261%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.0V and beta_Voc=-0.261%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.76 V | 10 panels | 547.6 V | 18 panels |
| **-10 C (14 F)** | 53.48 V | 11 panels | 588.3 V | 18 panels |
| **0 C (32 F)** | 52.2 V | 11 panels | 574.2 V | 19 panels |
| **25 C (77 F STC)** | 49.0 V | 12 panels | 588.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI matched near 520.0 W STC and 49.0 V Voc, led by Bila Solar Inc AA520US-6x24GG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bila Solar Inc AA520US-6x24GG**](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa520us-6x24gg/) Bila Solar Inc | 520.0 W | Tie (0 W) | 49.0 V | 20.72% | 92.7% |
| [**ES Foundry Corp ES-DP8-H72L-520W**](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72l-520w/) ES Foundry Corp | 520.0 W | Tie (0 W) | 48.9 V | 20.88% | 93.2% |
| [**Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520**](https://epri-peac.com/solar-equipment/modules/jiangsu-green-energy-power-technology-co-ltd/jiangsu-green-energy-power-technology-co-ltd-geo-pm10-72d520/) Jiangsu Green Energy Power Technology Co Ltd | 520.0 W | Tie (0 W) | 48.9 V | 20.63% | 93.8% |
| [**Heliene 144HC-520 M10 SL Bifacial**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-520-m10-sl-bifacial/) Heliene | 520.0 W | Tie (0 W) | 49.22 V | 20.16% | 94.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI (520.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI reaches 54.76 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (443 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI 8 kW Residential Fit

Needs 16 modules (443 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bila Solar Inc AA520US-6x24GG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 488.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI's 13.53 A short-circuit current by 1.56 equals 21.11 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.48 V cold Voc at 14 F and handles 13.53 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI at 11 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Bila Solar Inc AA520US-6x24GG specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S455YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s455yi/)