title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (435.0W, 49.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s435xi/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI: 435.0W STC, 49.7V Voc, 19-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI is a 435.0 W STC (406.3 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.23% efficiency, 49.7 V Voc at 25 C, and 54.21 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 406.3 W

- **Voc @ 25C** : 49.7 V

- **Efficiency** : 20.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from HYUNDAI ENERGY SOLUTIONS CO LTD and peers, HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI stands 25.0 W above the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Higher 49.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI (435.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,658

### 20.23% Aperture Efficiency

Power density 202.3 W/m2 (0.32 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.21 V at -10 C (596.3 V string) and 55.49 V at -20 C (10 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,720 W PTC; NEC 690.8 OCPD floor is 17.57 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.7 * (1 + (-0.259/100) * (-10 - 25)) = 54.21 V | OCPD = 1.56 * 11.26 = 17.57 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI: Voc=49.7 V, beta_Voc=-0.259%/C, Isc=11.26 A, STC=435.0 W, Area=2.15 m2.

**Result:** 11 panels max on 600 V (596.3 V); 19 panels for 8 kW (440 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 406.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.8 V / 10.67 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.259 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.23% (2.15 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 324 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 440 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 532 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI mechanical and cell layout.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S425XI** | 425.0 W | 396.7 W | 49.3 V | 40.4 V | 19.77% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S430XI** | 430.0 W | 401.5 W | 49.5 V | 40.6 V | 20.0% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI** | 435.0 W | 406.3 W | 49.7 V | 40.8 V | 20.23% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S440XI** | 440.0 W | 411.1 W | 49.9 V | 41.0 V | 20.47% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S445XI** | 445.0 W | 415.9 W | 50.1 V | 41.2 V | 20.7% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI (54.21 V at 14 F).

Computed from Voc=49.7V and beta_Voc=-0.259%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.49 V | 10 panels | 554.9 V | 18 panels |
| **-10 C (14 F)** | 54.21 V | 11 panels | 596.3 V | 18 panels |
| **0 C (32 F)** | 52.92 V | 11 panels | 582.1 V | 18 panels |
| **25 C (77 F STC)** | 49.7 V | 12 panels | 596.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf26-435w-blk/) Aptos Solar Technology LLC | 435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| [**Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-mf26-435w-wht/) Aptos Solar Technology LLC | 435.0 W | Tie (0 W) | 49.7 V | 20.71% | 92.8% |
| [**CertainTeed CT435HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct435hc11-06/) CertainTeed | 435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| [**AXITEC AC-435MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435mh-144v/) AXITEC | 435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI (435.0 W STC, 49.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI reaches 55.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 440 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI 8 kW Residential Fit

Needs 19 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 406.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI's 11.26 A short-circuit current by 1.56 equals 17.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.21 V cold Voc at 14 F and handles 11.26 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI at 11 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)