title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs #4 | WireAndSun"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s420xi-bk/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK): 420.0W STC, 49.1V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) is a 420.0 W STC (390.9 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.53% efficiency, 49.1 V Voc at 25 C, and 53.6 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 390.9 W

- **Voc @ 25C** : 49.1 V

- **Efficiency** : 19.53%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK): PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 420.0 W STC and 390.9 W PTC, HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) sits +35.0 W vs all-CEC median (top 37.8%; higher than 62.2% of peers) among 21,677 listed modules. Power density reaches 195.3 W/m2 (0.38 percentage points below 19.91% CEC median). Higher 49.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer DualSun SAS DualSun 420M-144-01 rates 420.0 W.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) (420.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK)?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK)?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,092

### 19.53% Aperture Efficiency

Power density 195.3 W/m2 (0.38 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.6 V at -10 C (589.6 V string) and 54.89 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 43.0 m2 (463 sq ft) producing 7,818 W PTC; NEC 690.8 OCPD floor is 17.22 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.1 * (1 + (-0.262/100) * (-10 - 25)) = 53.6 V | OCPD = 1.56 * 11.04 = 17.22 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK): Voc=49.1 V, beta_Voc=-0.262%/C, Isc=11.04 A, STC=420.0 W, Area=2.15 m2.

**Result:** 11 panels max on 600 V (589.6 V); 20 panels for 8 kW (463 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK)?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 390.9 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.2 V / 10.45 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.262 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.53% (2.15 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 347 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 463 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 555 sq ft | $2,523 | $4,266 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) (53.6 V at 14 F).

Computed from Voc=49.1V and beta_Voc=-0.262%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.89 V | 10 panels | 548.9 V | 18 panels |
| **-10 C (14 F)** | 53.6 V | 11 panels | 589.6 V | 18 panels |
| **0 C (32 F)** | 52.32 V | 11 panels | 575.5 V | 19 panels |
| **25 C (77 F STC)** | 49.1 V | 12 panels | 589.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK)?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) in nameplate wattage and Voc, starting with DualSun SAS DualSun 420M-144-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DualSun SAS DualSun 420M-144-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/) DualSun SAS | 420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| [**BYD Company Limited BYD400MIK-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd400mik-36/) BYD Company Limited | 410.0 W | -10.0 W | 49.21 V | 20.4% | 94.0% |
| [**AXITEC AC-410MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mh-144v/) AXITEC | 410.0 W | -10.0 W | 48.91 V | 20.71% | 93.5% |
| [**AXITEC AC-410MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mb-144v/) AXITEC | 410.0 W | -10.0 W | 49.3 V | 21.03% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) (420.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) reaches 54.89 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 463 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (463 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) 8 kW Residential Fit

Needs 20 modules (463 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 390.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) cold Voc rises from 49.1 V to 53.6 V (beta_Voc -0.262%/C), capping a 600 V string at 11 panels (589.6 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) need?

An 8 kW DC system uses 20 HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) modules (8,400 W STC / 7,818 W PTC), covering roughly 463 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) compare against DualSun SAS DualSun 420M-144-01?

HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK) outputs 420.0 W STC (49.1 V Voc, rank #7,910 of 21,677), while DualSun SAS DualSun 420M-144-01 delivers 420.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, DualSun SAS DualSun 420M-144-01 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK).

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)