title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (295.0W, 39.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hid-s295rg-bk/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK): 295.0W STC, 39.8V Voc, 28-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) is a 295.0 W STC (266.7 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.8 V Voc at 25 C, and 43.81 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 266.7 W

- **Voc @ 25C** : 39.8 V

- **Efficiency** : 18.21%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK): PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 295.0 W STC and 266.7 W PTC, HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) sits -90.0 W vs all-CEC median (below all-CEC median; higher than 20.4% of peers) among 21,677 listed modules. Power density reaches 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). Lower 39.8 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/60295 rates 295.0 W.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) (295.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK)?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK)?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,805

### 18.21% Aperture Efficiency

Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.81 V at -10 C (569.5 V string) and 44.96 V at -20 C (13 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,468 W PTC; NEC 690.8 OCPD floor is 15.26 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.8 * (1 + (-0.288/100) * (-10 - 25)) = 43.81 V | OCPD = 1.56 * 9.78 = 15.26 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK): Voc=39.8 V, beta_Voc=-0.288%/C, Isc=9.78 A, STC=295.0 W, Area=1.62 m2.

**Result:** 13 panels max on 600 V (569.5 V); 28 panels for 8 kW (488 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK)?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 266.7 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.3 V / 9.25 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.288 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.21% (1.62 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 366 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 488 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 593 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) mechanical and cell layout.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S290RG(BK)** | 290.0 W | 262.0 W | 39.6 V | 31.9 V | 17.9% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK)** | 295.0 W | 266.7 W | 39.8 V | 32.3 V | 18.21% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) (43.81 V at 14 F).

Computed from Voc=39.8V and beta_Voc=-0.288%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.96 V | 13 panels | 584.5 V | 22 panels |
| **-10 C (14 F)** | 43.81 V | 13 panels | 569.5 V | 22 panels |
| **0 C (32 F)** | 42.67 V | 14 panels | 597.4 V | 23 panels |
| **25 C (77 F STC)** | 39.8 V | 15 panels | 597.0 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK)?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-M6/60295**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60295/) GCL System Integration Technology Co Ltd | 295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| [**CSI Solar Co Ltd CS3K-295MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3k-295ms/) CSI Solar Co Ltd | 295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| [**CertainTeed CT290M10-02**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct290m10-02/) CertainTeed | 290.0 W | -5.0 W | 39.77 V | 17.83% | 91.8% |
| [**CertainTeed CT290M11-02**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct290m11-02/) CertainTeed | 290.0 W | -5.0 W | 39.77 V | 17.83% | 91.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) (295.0 W STC, 39.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) reaches 44.96 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) 8 kW Residential Fit

Needs 28 modules (488 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 266.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) cold Voc rises from 39.8 V to 43.81 V (beta_Voc -0.288%/C), capping a 600 V string at 13 panels (569.5 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) need?

An 8 kW DC system uses 28 HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) modules (8,260 W STC / 7,468 W PTC), covering roughly 488 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) compare against GCL System Integration Technology Co Ltd GCL-M6/60295?

HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK) outputs 295.0 W STC (39.8 V Voc, rank #16,890 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, GCL System Integration Technology Co Ltd GCL-M6/60295 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK).

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)