# HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG is a 365.0 W STC (341.3 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.04% efficiency, 40.59 V Voc at 25 C, and 44.5 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 365.0 W

- **PTC Wattage** : 341.3 W

- **Voc @ 25C** : 40.59 V

- **Efficiency** : 20.04%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG (Mono-c-Si) residential solar systems.

Homeowners evaluating HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG need 17 panels for 6 kW or 22 panels (431 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft). Under NEC 690.7(A), beta_Voc (-0.275%/C) pushes open-circuit voltage to 44.5 V at 14 F and 45.61 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG (365.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #12,044 / 21,677

### 365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,397

### 20.04% Aperture Efficiency

Power density 200.3 W/m2 (0.13 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.5 V at -10 C (578.5 V string) and 45.61 V at -20 C (13 max).

 8 kW Reference Array

### 22 Panels = 8,030 W STC

Occupies 40.1 m2 (431 sq ft) producing 7,509 W PTC; NEC 690.8 OCPD floor is 17.6 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.59 * (1 + (-0.275/100) * (-10 - 25)) = 44.5 V | OCPD = 1.56 * 11.28 = 17.6 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG: Voc=40.59 V, beta_Voc=-0.275%/C, Isc=11.28 A, STC=365.0 W, Area=1.822 m2.

**Result:** 13 panels max on 600 V (578.5 V); 22 panels for 8 kW (431 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG including Isc (11.28 A), Voc (40.59 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 341.3 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.59 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.92 V / 10.76 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.275 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.04% (1.822 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.21 kW | 333 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 22 | 8.03 kW | 431 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 28 | 10.22 kW | 549 sq ft | $2,558 | $4,325 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355XG** | 355.0 W | 331.7 W | 39.95 V | 33.21 V | 19.49% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360XG** | 360.0 W | 336.5 W | 40.26 V | 33.58 V | 19.76% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG** | 365.0 W | 341.3 W | 40.59 V | 33.92 V | 20.04% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370XG** | 370.0 W | 346.1 W | 40.91 V | 34.26 V | 20.31% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG (40.59 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.59V and beta_Voc=-0.275%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.61 V | 13 panels | 592.9 V | 21 panels |
| **-10 C (14 F)** | 44.5 V | 13 panels | 578.5 V | 22 panels |
| **0 C (32 F)** | 43.38 V | 13 panels | 563.9 V | 23 panels |
| **25 C (77 F STC)** | 40.59 V | 14 panels | 568.3 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-bhc-365w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 20.51% | 92.6% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-365w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 20.17% | 92.3% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-365w-black/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 19.95% | 93.3% |
| [**Aptos Solar Technology LLC DNA-120-MF26-365W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf26-365w/) Aptos Solar Technology LLC | 365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG (365.0 W STC, 40.59 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG reaches 45.61 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 341.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG PTC wattage (341.3 W) lower than STC (365.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 341.3 W PTC (93.5% retention) across HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG's 1.822 m2 aperture.

### Who should skip HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG panels (431 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

### What is the 1,000 V commercial string limit for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG?

On 1,000 V commercial inverters at -10 C (44.5 V cold Voc), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG fits up to 22 panels per series string.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)