---
title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs #11 | WireAndSun"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hia-s365xg-bk/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK): 365.0W STC, 40.59V Voc, 22-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) is a 365.0 W STC (339.8 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.04% efficiency, 40.59 V Voc at 25 C, and 44.61 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 365.0 W

- **PTC Wattage** : 339.8 W

- **Voc @ 25C** : 40.59 V

- **Efficiency** : 20.04%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) pairs strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677) with 40.59 V nominal Voc. An 8 kW residential build (8,030 W DC, 7,476 W PTC) saves ~$2,010/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W offers a 365.0 W alternative.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) on STC wattage, thermal PTC/STC retention, and 20.04 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #12,044 / 21,677

### 365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,397

### 20.04% Aperture Efficiency

Power density 200.3 W/m2 (0.13 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.61 V at -10 C (579.9 V string) and 45.76 V at -20 C (13 max).

 8 kW Reference Array

### 22 Panels = 8,030 W STC

Occupies 40.1 m2 (431 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 17.6 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.59 * (1 + (-0.283/100) * (-10 - 25)) = 44.61 V | OCPD = 1.56 * 11.28 = 17.6 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK): Voc=40.59 V, beta_Voc=-0.283%/C, Isc=11.28 A, STC=365.0 W, Area=1.822 m2.

**Result:** 13 panels max on 600 V (579.9 V); 22 panels for 8 kW (431 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 339.8 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.59 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.92 V / 10.76 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.283 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.04% (1.822 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (431 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.21 kW | 333 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 22 | 8.03 kW | 431 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 28 | 10.22 kW | 549 sq ft | $2,558 | $4,325 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Sibling wattage bins and frame colors grouped with HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) under HYUNDAI ENERGY SOLUTIONS CO LTD to prevent duplicate spec pages.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355XG(BK)** | 355.0 W | 330.2 W | 39.95 V | 33.21 V | 19.49% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360XG(BK)** | 360.0 W | 335.0 W | 40.26 V | 33.58 V | 19.76% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)** | 365.0 W | 339.8 W | 40.59 V | 33.92 V | 20.04% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370XG(BK)** | 370.0 W | 344.6 W | 40.91 V | 34.26 V | 20.31% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (beta_Voc -0.283%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.59V and beta_Voc=-0.283%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.76 V | 13 panels | 594.9 V | 21 panels |
| **-10 C (14 F)** | 44.61 V | 13 panels | 579.9 V | 22 panels |
| **0 C (32 F)** | 43.46 V | 13 panels | 565.0 V | 23 panels |
| **25 C (77 F STC)** | 40.59 V | 14 panels | 568.3 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) matched near 365.0 W STC and 40.59 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-bhc-365w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 20.51% | 92.6% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-365w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 20.17% | 92.3% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-hc-365w-black/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 365.0 W | Tie (0 W) | 40.7 V | 19.95% | 93.3% |
| [**Aptos Solar Technology LLC DNA-120-MF26-365W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf26-365w/) Aptos Solar Technology LLC | 365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC, 40.59 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) reaches 45.76 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)'s 11.28 A short-circuit current by 1.56 equals 17.6 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.61 V cold Voc at 14 F and handles 11.28 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) at 13 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK).

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)
