Manufacturer: [**Helios USA**](https://epri-peac.com/solar-equipment/brands/helios-usa/) Registry: **CEC Verified Engineering Specification**

Helios USA 6TA is a 255.0 W STC (229.6 W PTC) Mono-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.33% efficiency, 37.5 V Voc at 25 C, and 42.41 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 255.0 W

- **PTC Wattage** : 229.6 W

- **Voc @ 25C** : 37.5 V

- **Efficiency** : 15.33%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Helios USA 6TA Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Helios USA 6TA (Mono-c-Si) residential solar systems.

Homeowners evaluating Helios USA 6TA need 24 panels for 6 kW or 32 panels (573 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (573 sq ft). Under NEC 690.7(A), beta_Voc (-0.374%/C) pushes open-circuit voltage to 42.41 V at 14 F and 43.81 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Helios USA 6TA Fall Across Listed CEC Models?

Comparison of Helios USA 6TA (255.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define Helios USA 6TA?

Relative ranking of Helios USA 6TA across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for Helios USA 6TA?

Summary of Helios USA 6TA output rank, 8 kW array size (32 panels), efficiency rating, and 600 V string limit.

Rank #19,421 / 21,677

### 255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,243

### 15.33% Aperture Efficiency

Power density 153.3 W/m2 (4.58 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.41 V at -10 C (593.7 V string) and 43.81 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,160 W STC

Occupies 53.2 m2 (573 sq ft) producing 7,347 W PTC; NEC 690.8 OCPD floor is 13.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.374/100) * (-10 - 25)) = 42.41 V | OCPD = 1.56 * 8.86 = 13.82 A

Inputs from CEC Modules.csv for Helios USA 6TA: Voc=37.5 V, beta_Voc=-0.374%/C, Isc=8.86 A, STC=255.0 W, Area=1.663 m2.

**Result:** 14 panels max on 600 V (593.7 V); 32 panels for 8 kW (573 sq ft).

## What Are the Published CEC Specifications for Helios USA 6TA?

Complete CEC test sheet for Helios USA 6TA including Isc (8.86 A), Voc (37.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Helios USA 6TA.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 229.6 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.65 V / 8.32 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.374 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.33% (1.663 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Helios USA 6TA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Helios USA 6TA.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.12 kW | 430 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 32 | 8.16 kW | 573 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 40 | 10.2 kW | 716 sq ft | $2,553 | $4,317 |

## How Many Helios USA 6TA Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Helios USA 6TA (37.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.5V and beta_Voc=-0.374%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.81 V | 13 panels | 569.5 V | 22 panels |
| **-10 C (14 F)** | 42.41 V | 14 panels | 593.7 V | 23 panels |
| **0 C (32 F)** | 41.01 V | 14 panels | 574.1 V | 24 panels |
| **25 C (77 F STC)** | 37.5 V | 16 panels | 600.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Helios USA 6TA?

Four comparable CEC modules such as Advance Power API-P255 (255.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-P255**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p255/) Advance Power | 255.0 W | Tie (0 W) | 37.5 V | 15.57% | 89.4% |
| [**Auxin Solar AXN6P610T255**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p610t255/) Auxin Solar | 255.0 W | Tie (0 W) | 37.5 V | 15.57% | 89.4% |
| [**Eoplly New Energy Technology EP156M/60-255 AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-255-ac/) Eoplly New Energy Technology | 255.0 W | Tie (0 W) | 37.56 V | 15.76% | 89.9% |
| [**Eoplly New Energy Technology EP156M/60-255S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-255s-ac/) Eoplly New Energy Technology | 255.0 W | Tie (0 W) | 37.56 V | 15.76% | 89.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Helios USA 6TA?

Evaluate Helios USA 6TA (255.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Helios USA 6TA reaches 43.81 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 573 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (573 sq ft).
- 2026 tax credit baseline: cash residential installs of Helios USA 6TA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Helios USA 6TA 8 kW Residential Fit

Needs 32 modules (573 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-P255.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Helios USA 6TA by Helios USA grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Helios USA 6TA PTC wattage (229.6 W) lower than STC (255.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 229.6 W PTC (90.0% retention) across Helios USA 6TA's 1.663 m2 aperture.

### Who should skip Helios USA 6TA on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 Helios USA 6TA panels (573 sq ft) leave unusable roof gaps vs. Advance Power API-P255.

### What is the 1,000 V commercial string limit for Helios USA 6TA?

On 1,000 V commercial inverters at -10 C (42.41 V cold Voc), Helios USA 6TA fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Helios USA 6TA.

## Related Pages

Compare Helios USA equipment, Advance Power API-P255 specs, utility payback rates, and NEC string calculators alongside Helios USA 6TA.

[All Helios USA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/helios-usa/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Helios USA

- [All Helios USA Specs](https://epri-peac.com/solar-equipment/brands/helios-usa/)