---
title: "Heliene 72M-395 G1 Specs (395.0W, 49.26V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-72m-395-g1/
description: "CEC datasheet for Heliene 72M-395 G1: 395.0W STC, 49.26V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Heliene 72M-395 G1 — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 72M-395 G1 is a 395.0 W STC (365.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.57% efficiency, 49.26 V Voc at 25 C, and 53.74 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 365.4 W

- **Voc @ 25C** : 49.26 V

- **Efficiency** : 20.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 72M-395 G1 Compare Against Peer CEC Listings?

Engineering position of Heliene 72M-395 G1 (395.0 W STC) vs. ELITE Solar ET-M672BH395WW across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), Heliene 72M-395 G1 operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Higher 49.26 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677), 21 panels occupy 434 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Heliene 72M-395 G1 Fall Across Listed CEC Models?

Plots Heliene 72M-395 G1 at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 72M-395 G1?

Benchmarks Heliene 72M-395 G1 on STC wattage, thermal PTC/STC retention, and 20.57 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Heliene 72M-395 G1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 72M-395 G1 by Heliene.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,219

### 20.57% Aperture Efficiency

Power density 205.7 W/m2 (0.66 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.74 V at -10 C (591.1 V string) and 55.02 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,673 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.26 * (1 + (-0.26/100) * (-10 - 25)) = 53.74 V | OCPD = 1.56 * 10.29 = 16.05 A

Inputs from CEC Modules.csv for Heliene 72M-395 G1: Voc=49.26 V, beta_Voc=-0.26%/C, Isc=10.29 A, STC=395.0 W, Area=1.92 m2.

**Result:** 11 panels max on 600 V (591.1 V); 21 panels for 8 kW (434 sq ft).

## What Are the Published CEC Specifications for Heliene 72M-395 G1?

Laboratory test ratings recorded for Heliene 72M-395 G1 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M-395 G1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 365.4 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.4 V / 9.78 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.26 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.57% (1.92 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Heliene 72M-395 G1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (434 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 72M-395 G1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 331 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 434 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 537 sq ft | $2,570 | $4,347 |

## How Many Heliene 72M-395 G1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 72M-395 G1 (beta_Voc -0.26%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.26V and beta_Voc=-0.26%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.02 V | 10 panels | 550.2 V | 18 panels |
| **-10 C (14 F)** | 53.74 V | 11 panels | 591.1 V | 18 panels |
| **0 C (32 F)** | 52.46 V | 11 panels | 577.1 V | 19 panels |
| **25 C (77 F STC)** | 49.26 V | 12 panels | 591.1 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 72M-395 G1?

Closest cross-brand CEC competitors to Heliene 72M-395 G1 matched near 395.0 W STC and 49.26 V Voc, led by ELITE Solar ET-M672BH395WW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ELITE Solar ET-M672BH395WW**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395ww/) ELITE Solar | 395.0 W | Tie (0 W) | 49.5 V | 19.85% | 93.3% |
| [**ELITE Solar ET-M672BH395GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395gl/) ELITE Solar | 395.0 W | Tie (0 W) | 49.6 V | 19.36% | 93.2% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-bhc-395w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-hc-395w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 72M-395 G1?

Evaluate Heliene 72M-395 G1 (395.0 W STC, 49.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M-395 G1 reaches 55.02 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (434 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 72M-395 G1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 72M-395 G1 8 kW Residential Fit

Needs 21 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M672BH395WW.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M-395 G1 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Heliene 72M-395 G1 panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 72M-395 G1 cold Voc rises from 49.26 V to 53.74 V (beta_Voc -0.26%/C), capping a 600 V string at 11 panels (591.1 V).

### How much roof area does an 8 kW array of Heliene 72M-395 G1 need?

An 8 kW DC system uses 21 Heliene 72M-395 G1 modules (8,295 W STC / 7,673 W PTC), covering roughly 434 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

### How does Heliene 72M-395 G1 compare against ELITE Solar ET-M672BH395WW?

Heliene 72M-395 G1 outputs 395.0 W STC (49.26 V Voc, rank #9,869 of 21,677), while ELITE Solar ET-M672BH395WW delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Heliene equipment, ELITE Solar ET-M672BH395WW specs, utility payback rates, and NEC string calculators alongside Heliene 72M-395 G1.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)
