title: "Heliene 72M-370 Bifacial Specs (370.0W, 47.19V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-72m-370-bifacial/
description: "CEC datasheet for Heliene 72M-370 Bifacial: 370.0W STC, 47.19V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Heliene 72M-370 Bifacial — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 72M-370 Bifacial is a 370.0 W STC (339.2 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.89% efficiency, 47.19 V Voc at 25 C, and 51.65 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 370.0 W

- **PTC Wattage** : 339.2 W

- **Voc @ 25C** : 47.19 V

- **Efficiency** : 19.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 72M-370 Bifacial Compare Against Peer CEC Listings?

Engineering position of Heliene 72M-370 Bifacial (370.0 W STC) vs. CSI Solar Co Ltd CS3U-360MB-AG across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Heliene 72M-370 Bifacial pairs strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677) with 47.19 V nominal Voc. An 8 kW residential build (8,140 W DC, 7,462 W PTC) saves ~$2,037/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer CSI Solar Co Ltd CS3U-360MB-AG offers a 360.0 W alternative.

## Where Does Heliene 72M-370 Bifacial Fall Across Listed CEC Models?

Plots Heliene 72M-370 Bifacial at 370.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 72M-370 Bifacial?

Benchmarks Heliene 72M-370 Bifacial on STC wattage, thermal PTC/STC retention, and 19.89 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Heliene 72M-370 Bifacial?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 72M-370 Bifacial by Heliene.

Rank #11,697 / 21,677

### 370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,917

### 19.89% Aperture Efficiency

Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.65 V at -10 C (568.1 V string) and 52.92 V at -20 C (11 max).

 8 kW Reference Array

### 22 Panels = 8,140 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 15.37 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.19 * (1 + (-0.27/100) * (-10 - 25)) = 51.65 V | OCPD = 1.56 * 9.85 = 15.37 A

Inputs from CEC Modules.csv for Heliene 72M-370 Bifacial: Voc=47.19 V, beta_Voc=-0.27%/C, Isc=9.85 A, STC=370.0 W, Area=1.86 m2.

**Result:** 11 panels max on 600 V (568.1 V); 22 panels for 8 kW (440 sq ft).

## What Are the Published CEC Specifications for Heliene 72M-370 Bifacial?

Laboratory test ratings recorded for Heliene 72M-370 Bifacial (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M-370 Bifacial.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 339.2 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.19 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.15 V / 9.2 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.27 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.89% (1.86 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Heliene 72M-370 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (440 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 72M-370 Bifacial.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.29 kW | 340 sq ft | $1,574 | $2,662 |
| **8 kW Class** | 22 | 8.14 kW | 440 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 28 | 10.36 kW | 561 sq ft | $2,593 | $4,385 |

## How Many Heliene 72M-370 Bifacial Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 72M-370 Bifacial (beta_Voc -0.27%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.19V and beta_Voc=-0.27%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.92 V | 11 panels | 582.1 V | 18 panels |
| **-10 C (14 F)** | 51.65 V | 11 panels | 568.1 V | 19 panels |
| **0 C (32 F)** | 50.38 V | 11 panels | 554.2 V | 19 panels |
| **25 C (77 F STC)** | 47.19 V | 12 panels | 566.3 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 72M-370 Bifacial?

Closest cross-brand CEC competitors to Heliene 72M-370 Bifacial matched near 370.0 W STC and 47.19 V Voc, led by CSI Solar Co Ltd CS3U-360MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-360MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-360mb-ag/) CSI Solar Co Ltd | 360.0 W | -10.0 W | 47.0 V | 18.56% | 93.8% |
| [**CSI Solar Co Ltd CS3U-360PB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-360pb-ag/) CSI Solar Co Ltd | 360.0 W | -10.0 W | 47.0 V | 18.56% | 92.5% |
| [**Auxin Solar AXN6M612B360**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612b360/) Auxin Solar | 360.0 W | -10.0 W | 47.56 V | 18.28% | 93.0% |
| [**CSI Solar Co Ltd CS3U-380PB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-380pb-ag/) CSI Solar Co Ltd | 380.0 W | +10.0 W | 47.8 V | 19.29% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 72M-370 Bifacial?

Evaluate Heliene 72M-370 Bifacial (370.0 W STC, 47.19 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M-370 Bifacial reaches 52.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (440 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 72M-370 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 72M-370 Bifacial 8 kW Residential Fit

Needs 22 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-360MB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 339.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M-370 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Heliene 72M-370 Bifacial?

Multiplying Heliene 72M-370 Bifacial's 9.85 A short-circuit current by 1.56 equals 15.37 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Heliene 72M-370 Bifacial pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.65 V cold Voc at 14 F and handles 9.85 A Isc; string inverters cap Heliene 72M-370 Bifacial at 11 panels on 600 V.

### Is Heliene 72M-370 Bifacial eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 72M-370 Bifacial rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

## Related Pages

Compare Heliene equipment, CSI Solar Co Ltd CS3U-360MB-AG specs, utility payback rates, and NEC string calculators alongside Heliene 72M-370 Bifacial.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)