title: "Heliene 60M-325 Specs (325.0W, 40.67V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-60m-325/
description: "CEC datasheet for Heliene 60M-325: 325.0W STC, 40.67V Voc, 25-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Heliene 60M-325 — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 60M-325 is a 325.0 W STC (296.5 W PTC) Mono-c-Si solar module ranking #14,546 of 21,677 CEC listings (below all-CEC median; higher than 31.1% of peers). It delivers 19.68% efficiency, 40.67 V Voc at 25 C, and 44.54 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 325.0 W

- **PTC Wattage** : 296.5 W

- **Voc @ 25C** : 40.67 V

- **Efficiency** : 19.68%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 60M-325 Compare Against Peer CEC Listings?

How Heliene Heliene 60M-325 handles rooftop heat (296.5 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 60M-325 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 196.7 W/m2 (0.23 percentage points below 19.91% CEC median). Compared against CSI Solar Co Ltd CS3K-330MS (330.0 W), this model holds typical 91.2% PTC-to-STC thermal output (296.5 W real-world rating). Mid-range 40.67 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.8 A overcurrent floor served by a 20 A breaker.

## Where Does Heliene 60M-325 Fall Across Listed CEC Models?

Where Heliene 60M-325 (325.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 60M-325?

Percentile placement of Heliene 60M-325 across power density (196.7 W/m2), thermal retention, and nameplate STC wattage. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for Heliene 60M-325?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 60M-325 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #14,546 / 21,677

### 325.0 W STC · Higher Than 31.1%

325.0 W STC (-60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,558

### 19.68% Aperture Efficiency

Power density 196.7 W/m2 (0.23 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.54 V at -10 C (579.0 V string) and 45.65 V at -20 C (13 max).

 8 kW Reference Array

### 25 Panels = 8,125 W STC

Occupies 41.3 m2 (445 sq ft) producing 7,412 W PTC; NEC 690.8 OCPD floor is 15.8 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.67 * (1 + (-0.272/100) * (-10 - 25)) = 44.54 V | OCPD = 1.56 * 10.13 = 15.8 A

Inputs from CEC Modules.csv for Heliene 60M-325: Voc=40.67 V, beta_Voc=-0.272%/C, Isc=10.13 A, STC=325.0 W, Area=1.652 m2.

**Result:** 13 panels max on 600 V (579.0 V); 25 panels for 8 kW (445 sq ft).

## What Are the Published CEC Specifications for Heliene 60M-325?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 60M-325. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Heliene 60M-325.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 325.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 296.5 W (91.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.67 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.61 V / 9.41 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.68% (1.652 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Heliene 60M-325 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 60M-325 (325.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 19 | 6.17 kW | 338 sq ft | $1,544 | $2,611 |
| **8 kW Class** | 25 | 8.12 kW | 445 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 31 | 10.07 kW | 551 sq ft | $2,520 | $4,262 |

## How Many Heliene 60M-325 Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 60M-325 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.67V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.65 V | 13 panels | 593.4 V | 21 panels |
| **-10 C (14 F)** | 44.54 V | 13 panels | 579.0 V | 22 panels |
| **0 C (32 F)** | 43.44 V | 13 panels | 564.7 V | 23 panels |
| **25 C (77 F STC)** | 40.67 V | 14 panels | 569.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 60M-325?

Alternative CEC solar modules from competing brands near Heliene 60M-325 (325.0 W), including CSI Solar Co Ltd CS3K-330MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3K-330MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3k-330ms/) CSI Solar Co Ltd | 330.0 W | +5.0 W | 40.5 V | 20.62% | 93.2% |
| [**Auxin Solar AXN6M610T325**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m610t325/) Auxin Solar | 325.0 W | Tie (0 W) | 42.2 V | 19.98% | 91.9% |
| [**Boviet Solar Technology Co Ltd BVM6610M-320L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-320l-h/) Boviet Solar Technology Co Ltd | 320.0 W | -5.0 W | 40.95 V | 19.16% | 93.6% |
| [**GCL System Integration Technology Co Ltd GCL-M6/60320**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60320/) GCL System Integration Technology Co Ltd | 320.0 W | -5.0 W | 40.3 V | 19.63% | 91.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 60M-325?

Evaluate Heliene 60M-325 (325.0 W STC, 40.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 60M-325 reaches 45.65 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (445 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 60M-325 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 60M-325 8 kW Residential Fit

Needs 25 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3K-330MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 296.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 60M-325 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

### What fuse or breaker size does NEC 690.8 require for Heliene 60M-325?

Multiplying Heliene 60M-325's 10.13 A short-circuit current by 1.56 equals 15.8 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 60M-325 before finalizing component orders.

### Can Heliene 60M-325 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.54 V cold Voc at 14 F and handles 10.13 A Isc; string inverters cap Heliene 60M-325 at 13 panels on 600 V.

### Is Heliene 60M-325 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 60M-325 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare Heliene equipment, CSI Solar Co Ltd CS3K-330MS specs, utility payback rates, and NEC string calculators alongside Heliene 60M-325.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)