title: "Heliene 144HC-585 M10 NTYP SL Specs (585.0W, 53.12V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/
description: "CEC datasheet for Heliene 144HC-585 M10 NTYP SL Bifacial: 585.0W STC, 53.12V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Heliene 144HC-585 M10 NTYP SL Bifacial — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 144HC-585 M10 NTYP SL Bifacial is a 585.0 W STC (549.1 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 53.12 V Voc at 25 C, and 57.54 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 585.0 W

- **PTC Wattage** : 549.1 W

- **Voc @ 25C** : 53.12 V

- **Efficiency** : 22.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 144HC-585 M10 NTYP SL Bifacial Compare Against Peer CEC Listings?

How Heliene Heliene 144HC-585 M10 NTYP SL Bifacial handles rooftop heat (549.1 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 144HC-585 M10 NTYP SL Bifacial (Mono-c-Si) as a large-format commercial and ground-mount module delivering 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). Compared against FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585 (585.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 53.12 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.51 A overcurrent floor served by a 25 A breaker.

## Where Does Heliene 144HC-585 M10 NTYP SL Bifacial Fall Across Listed CEC Models?

Where Heliene 144HC-585 M10 NTYP SL Bifacial (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 144HC-585 M10 NTYP SL Bifacial?

Percentile placement of Heliene 144HC-585 M10 NTYP SL Bifacial across power density (226.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Heliene 144HC-585 M10 NTYP SL Bifacial?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 144HC-585 M10 NTYP SL Bifacial specifications.

Rank #1,751 / 21,677

### Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,698

### 22.67% Aperture Efficiency

Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.54 V at -10 C (575.4 V string) and 58.81 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,190 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,687 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.12 * (1 + (-0.238/100) * (-10 - 25)) = 57.54 V | OCPD = 1.56 * 13.79 = 21.51 A

Inputs from CEC Modules.csv for Heliene 144HC-585 M10 NTYP SL Bifacial: Voc=53.12 V, beta_Voc=-0.238%/C, Isc=13.79 A, STC=585.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (575.4 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for Heliene 144HC-585 M10 NTYP SL Bifacial?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 144HC-585 M10 NTYP SL Bifacial.

Official California Energy Commission (NREL SAM) test parameters for Heliene 144HC-585 M10 NTYP SL Bifacial.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 549.1 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 44.93 V / 13.03 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.238 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.67% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Heliene 144HC-585 M10 NTYP SL Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 144HC-585 M10 NTYP SL Bifacial (585.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| **8 kW Class** | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |

## Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 144HC-585 M10 NTYP SL Bifacial architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Heliene 144HC-585 M10 NTYP SL Bifacial wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Heliene 144HC-575 M10 NTYP SL Bifacial** | 575.0 W | 539.5 W | 52.83 V | 44.48 V | 22.29% |
| **Heliene 144HC-580 M10 NTYP SL Bifacial** | 580.0 W | 544.3 W | 52.97 V | 44.74 V | 22.48% |
| **Heliene 144HC-585 M10 NTYP SL Bifacial** | 585.0 W | 549.1 W | 53.12 V | 44.93 V | 22.67% |
| **Heliene 144HC-590 M10 NTYP SL Bifacial** | 590.0 W | 554.0 W | 53.25 V | 44.96 V | 22.87% |
| **Heliene 144HC-595 M10 NTYP SL Bifacial** | 595.0 W | 558.8 W | 53.4 V | 45.2 V | 23.06% |

## How Many Heliene 144HC-585 M10 NTYP SL Bifacial Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 144HC-585 M10 NTYP SL Bifacial from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.12V and beta_Voc=-0.238%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.81 V | 10 panels | 588.1 V | 17 panels |
| **-10 C (14 F)** | 57.54 V | 10 panels | 575.4 V | 17 panels |
| **0 C (32 F)** | 56.28 V | 10 panels | 562.8 V | 17 panels |
| **25 C (77 F STC)** | 53.12 V | 11 panels | 584.3 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-585 M10 NTYP SL Bifacial?

Alternative CEC solar modules from competing brands near Heliene 144HC-585 M10 NTYP SL Bifacial (585.0 W), including FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585**](https://epri-peac.com/solar-equipment/modules/fs-green-energies-private-limited/fs-green-energies-private-limited-fst-m10144g-585/) FS GREEN ENERGIES PRIVATE LIMITED | 585.0 W | Tie (0 W) | 53.1 V | 22.85% | 95.0% |
| [**GOLDI SUN PRIVATE LIMITED GS10-T144-GF-585**](https://epri-peac.com/solar-equipment/modules/goldi-sun-private-limited/goldi-sun-private-limited-gs10-t144-gf-585/) GOLDI SUN PRIVATE LIMITED | 585.0 W | Tie (0 W) | 53.1 V | 22.67% | 93.8% |
| [**AMPS Solar AMPS-585N-144SW**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-585n-144sw/) AMPS Solar | 585.0 W | Tie (0 W) | 52.7 V | 22.85% | 94.9% |
| [**Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-585-h-hc-bf/) Boviet Solar Technology Co Ltd | 585.0 W | Tie (0 W) | 52.61 V | 22.67% | 95.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 144HC-585 M10 NTYP SL Bifacial?

Evaluate Heliene 144HC-585 M10 NTYP SL Bifacial (585.0 W STC, 53.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-585 M10 NTYP SL Bifacial reaches 58.81 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Heliene 144HC-585 M10 NTYP SL Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 144HC-585 M10 NTYP SL Bifacial 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 549.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 144HC-585 M10 NTYP SL Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Heliene 144HC-585 M10 NTYP SL Bifacial?

Multiplying Heliene 144HC-585 M10 NTYP SL Bifacial's 13.79 A short-circuit current by 1.56 equals 21.51 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Heliene 144HC-585 M10 NTYP SL Bifacial pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.54 V cold Voc at 14 F and handles 13.79 A Isc; string inverters cap Heliene 144HC-585 M10 NTYP SL Bifacial at 10 panels on 600 V.

### Is Heliene 144HC-585 M10 NTYP SL Bifacial eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 144HC-585 M10 NTYP SL Bifacial rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Heliene equipment, FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585 specs, utility payback rates, and NEC string calculators alongside Heliene 144HC-585 M10 NTYP SL Bifacial.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-585 M10 SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-585-m10-sl-bifacial/)