title: "Heliene 144HC-550 M10 SL Bifacial Specs (550.0W, 50.37V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-550-m10-sl-bifacial/
description: "CEC datasheet for Heliene 144HC-550 M10 SL Bifacial: 550.0W STC, 50.37V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Heliene 144HC-550 M10 SL Bifacial — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 144HC-550 M10 SL Bifacial is a 550.0 W STC (518.2 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.32% efficiency, 50.37 V Voc at 25 C, and 54.83 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 550.0 W

- **PTC Wattage** : 518.2 W

- **Voc @ 25C** : 50.37 V

- **Efficiency** : 21.32%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 144HC-550 M10 SL Bifacial Compare Against Peer CEC Listings?

How Heliene Heliene 144HC-550 M10 SL Bifacial handles rooftop heat (518.2 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 144HC-550 M10 SL Bifacial (Mono-c-Si) as a large-format commercial and ground-mount module delivering 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). Compared against Bluesun Solar CoLtd BSM550M10-72HBD (550.0 W), this model holds strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677). Higher 50.37 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.12 A overcurrent floor served by a 25 A breaker.

## Where Does Heliene 144HC-550 M10 SL Bifacial Fall Across Listed CEC Models?

Where Heliene 144HC-550 M10 SL Bifacial (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 144HC-550 M10 SL Bifacial?

Percentile placement of Heliene 144HC-550 M10 SL Bifacial across power density (213.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Heliene 144HC-550 M10 SL Bifacial?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 144HC-550 M10 SL Bifacial specifications.

Rank #2,737 / 21,677

### Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,973

### 21.32% Aperture Efficiency

Power density 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.83 V at -10 C (548.3 V string) and 56.1 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,250 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,773 W PTC; NEC 690.8 OCPD floor is 21.12 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.37 * (1 + (-0.253/100) * (-10 - 25)) = 54.83 V | OCPD = 1.56 * 13.54 = 21.12 A

Inputs from CEC Modules.csv for Heliene 144HC-550 M10 SL Bifacial: Voc=50.37 V, beta_Voc=-0.253%/C, Isc=13.54 A, STC=550.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (548.3 V); 15 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Heliene 144HC-550 M10 SL Bifacial?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 144HC-550 M10 SL Bifacial.

Official California Energy Commission (NREL SAM) test parameters for Heliene 144HC-550 M10 SL Bifacial.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 518.2 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.37 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.7 V / 12.89 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.253 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.32% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Heliene 144HC-550 M10 SL Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 144HC-550 M10 SL Bifacial (550.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.05 kW | 305 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 15 | 8.25 kW | 417 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 19 | 10.45 kW | 528 sq ft | $2,616 | $4,423 |

## How Many Heliene 144HC-550 M10 SL Bifacial Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 144HC-550 M10 SL Bifacial from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.37V and beta_Voc=-0.253%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.1 V | 10 panels | 561.0 V | 17 panels |
| **-10 C (14 F)** | 54.83 V | 10 panels | 548.3 V | 18 panels |
| **0 C (32 F)** | 53.56 V | 11 panels | 589.2 V | 18 panels |
| **25 C (77 F STC)** | 50.37 V | 11 panels | 554.1 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-550 M10 SL Bifacial?

Alternative CEC solar modules from competing brands near Heliene 144HC-550 M10 SL Bifacial (550.0 W), including Bluesun Solar CoLtd BSM550M10-72HBD.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bluesun Solar CoLtd BSM550M10-72HBD**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm550m10-72hbd/) Bluesun Solar CoLtd | 550.0 W | Tie (0 W) | 49.92 V | 21.23% | 92.4% |
| [**Convalt Manufacturing LLC CVLT550-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/convalt-manufacturing-llc/convalt-manufacturing-llc-cvlt550-144bmh-dg/) Convalt Manufacturing LLC | 550.0 W | Tie (0 W) | 49.92 V | 21.32% | 93.4% |
| [**AMPS Solar AMPS-550P-144BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/) AMPS Solar | 550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| [**Apollo Renewables Inc Apollo-M772BH-550TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m772bh-550tw/) Apollo Renewables Inc | 550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 144HC-550 M10 SL Bifacial?

Evaluate Heliene 144HC-550 M10 SL Bifacial (550.0 W STC, 50.37 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-550 M10 SL Bifacial reaches 56.1 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Heliene 144HC-550 M10 SL Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 144HC-550 M10 SL Bifacial 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM550M10-72HBD.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 518.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 144HC-550 M10 SL Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Heliene 144HC-550 M10 SL Bifacial?

Multiplying Heliene 144HC-550 M10 SL Bifacial's 13.54 A short-circuit current by 1.56 equals 21.12 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Heliene 144HC-550 M10 SL Bifacial pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.83 V cold Voc at 14 F and handles 13.54 A Isc; string inverters cap Heliene 144HC-550 M10 SL Bifacial at 10 panels on 600 V.

### Is Heliene 144HC-550 M10 SL Bifacial eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 144HC-550 M10 SL Bifacial rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare Heliene equipment, Bluesun Solar CoLtd BSM550M10-72HBD specs, utility payback rates, and NEC string calculators alongside Heliene 144HC-550 M10 SL Bifacial.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)