Heliene 144HC-460 Bifacial is a 460.0 W STC (429.8 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 20.81% efficiency, 51.26 V Voc at 25 C, and 55.96 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 460.0 W

- **PTC Wattage** : 429.8 W

- **Voc @ 25C** : 51.26 V

- **Efficiency** : 20.81%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 144HC-460 Bifacial Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 144HC-460 Bifacial (Mono-c-Si) residential solar systems.

Homeowners evaluating Heliene 144HC-460 Bifacial need 14 panels for 6 kW or 18 panels (428 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (428 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.262%/C) pushes open-circuit voltage to 55.96 V at 14 F and 57.3 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does Heliene 144HC-460 Bifacial Fall Across Listed CEC Models?

Comparison of Heliene 144HC-460 Bifacial (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define Heliene 144HC-460 Bifacial?

Relative ranking of Heliene 144HC-460 Bifacial across nameplate watts, 93.4% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for Heliene 144HC-460 Bifacial?

Summary of Heliene 144HC-460 Bifacial output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,199 / 21,677

### Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,197

### 20.81% Aperture Efficiency

Power density 208.1 W/m2 (0.90 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.96 V at -10 C (559.6 V string) and 57.3 V at -20 C (10 max).

 8 kW Reference Array

### 18 Panels = 8,280 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 18.61 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.26 * (1 + (-0.262/100) * (-10 - 25)) = 55.96 V | OCPD = 1.56 * 11.93 = 18.61 A

Inputs from CEC Modules.csv for Heliene 144HC-460 Bifacial: Voc=51.26 V, beta_Voc=-0.262%/C, Isc=11.93 A, STC=460.0 W, Area=2.21 m2.

**Result:** 10 panels max on 600 V (559.6 V); 18 panels for 8 kW (428 sq ft).

## What Are the Published CEC Specifications for Heliene 144HC-460 Bifacial?

Complete CEC test sheet for Heliene 144HC-460 Bifacial including Isc (11.93 A), Voc (51.26 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 144HC-460 Bifacial.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 429.8 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 51.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.31 V / 10.88 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.262 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.81% (2.21 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Heliene 144HC-460 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 144HC-460 Bifacial.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.44 kW | 333 sq ft | $1,612 | $2,726 |
| **8 kW Class** | 18 | 8.28 kW | 428 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 22 | 10.12 kW | 523 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 144HC-460 Bifacial series guide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Heliene 144HC-460 Bifacial wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Heliene 144HC-450 Bifacial** | 450.0 W | 420.2 W | 50.74 V | 42.17 V | 20.36% |
| **Heliene 144HC-460 Bifacial** | 460.0 W | 429.8 W | 51.26 V | 42.31 V | 20.81% |

## How Many Heliene 144HC-460 Bifacial Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 144HC-460 Bifacial (51.26 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=51.26V and beta_Voc=-0.262%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 57.3 V | 10 panels | 573.0 V | 17 panels |
| **-10 C (14 F)** | 55.96 V | 10 panels | 559.6 V | 17 panels |
| **0 C (32 F)** | 54.62 V | 10 panels | 546.2 V | 18 panels |
| **25 C (77 F STC)** | 51.26 V | 11 panels | 563.9 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-460 Bifacial?

Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-460PB-AG (460.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3Y-460PB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-460pb-ag/) CSI Solar Co Ltd | 460.0 W | Tie (0 W) | 52.0 V | 20.0% | 93.7% |
| [**Bluesun Solar CoLtd BSM455M-72HBD**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm455m-72hbd/) Bluesun Solar CoLtd | 455.0 W | -5.0 W | 50.6 V | 20.97% | 92.7% |
| [**Caterpillar Inc PVC455MB03H**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc455mb03h/) Caterpillar Inc | 455.0 W | -5.0 W | 49.8 V | 21.56% | 93.8% |
| [**CSI Solar Co Ltd CS3W-455MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-455mb-ag/) CSI Solar Co Ltd | 455.0 W | -5.0 W | 49.3 V | 21.06% | 92.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 144HC-460 Bifacial?

Evaluate Heliene 144HC-460 Bifacial (460.0 W STC, 51.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-460 Bifacial reaches 57.3 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (428 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 144HC-460 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 144HC-460 Bifacial 8 kW Residential Fit

Needs 18 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-460PB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 429.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 144HC-460 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Heliene 144HC-460 Bifacial PTC wattage (429.8 W) lower than STC (460.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 429.8 W PTC (93.4% retention) across Heliene 144HC-460 Bifacial's 2.21 m2 aperture.

### Who should skip Heliene 144HC-460 Bifacial on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Heliene 144HC-460 Bifacial panels (428 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-460PB-AG.

### What is the 1,000 V commercial string limit for Heliene 144HC-460 Bifacial?

On 1,000 V commercial inverters at -10 C (55.96 V cold Voc), Heliene 144HC-460 Bifacial fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 144HC-460 Bifacial.

## Related Pages

Compare Heliene equipment, CSI Solar Co Ltd CS3Y-460PB-AG specs, utility payback rates, and NEC string calculators alongside Heliene 144HC-460 Bifacial.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)