title: "Heliene 132HC-470 M10 SL Specs (470.0W, 45.25V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-132hc-470-m10-sl/
description: "CEC datasheet for Heliene 132HC-470 M10 SL: 470.0W STC, 45.25V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Heliene 132HC-470 M10 SL — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 132HC-470 M10 SL is a 470.0 W STC (442.8 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 20.52% efficiency, 45.25 V Voc at 25 C, and 49.21 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 470.0 W

- **PTC Wattage** : 442.8 W

- **Voc @ 25C** : 45.25 V

- **Efficiency** : 20.52%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 132HC-470 M10 SL Compare Against Peer CEC Listings?

Solar engineering breakdown for Heliene 132HC-470 M10 SL: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Heliene and peers, Heliene 132HC-470 M10 SL stands 60.0 W above the 410.0 W Mono-c-Si median and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,529-$2,588/yr in baseline US bill offset. Mid-range 45.25 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

## Where Does Heliene 132HC-470 M10 SL Fall Across Listed CEC Models?

Distribution marker showing Heliene 132HC-470 M10 SL (470.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Heliene 132HC-470 M10 SL?

Dataset percentiles tracking Heliene 132HC-470 M10 SL power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Heliene 132HC-470 M10 SL?

Benchmark highlights for Heliene 132HC-470 M10 SL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,967 / 21,677

### Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,460

### 20.52% Aperture Efficiency

Power density 205.2 W/m2 (0.61 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.21 V at -10 C (590.5 V string) and 50.34 V at -20 C (11 max).

 8 kW Reference Array

### 18 Panels = 8,460 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,970 W PTC; NEC 690.8 OCPD floor is 20.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.25 * (1 + (-0.25/100) * (-10 - 25)) = 49.21 V | OCPD = 1.56 * 13.21 = 20.61 A

Inputs from CEC Modules.csv for Heliene 132HC-470 M10 SL: Voc=45.25 V, beta_Voc=-0.25%/C, Isc=13.21 A, STC=470.0 W, Area=2.29 m2.

**Result:** 12 panels max on 600 V (590.5 V); 18 panels for 8 kW (444 sq ft).

## What Are the Published CEC Specifications for Heliene 132HC-470 M10 SL?

Official CEC datasheet figures for Heliene 132HC-470 M10 SL (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Heliene 132HC-470 M10 SL.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 442.8 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.21 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.7 V / 12.48 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.25 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.52% (2.29 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Heliene 132HC-470 M10 SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Heliene 132HC-470 M10 SL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.11 kW | 320 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 18 | 8.46 kW | 444 sq ft | $2,117 | $3,580 |
| **10 kW Class** | 22 | 10.34 kW | 542 sq ft | $2,588 | $4,376 |

## How Many Heliene 132HC-470 M10 SL Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 132HC-470 M10 SL (49.21 V at 14 F).

Computed from Voc=45.25V and beta_Voc=-0.25%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.34 V | 11 panels | 553.7 V | 19 panels |
| **-10 C (14 F)** | 49.21 V | 12 panels | 590.5 V | 20 panels |
| **0 C (32 F)** | 48.08 V | 12 panels | 577.0 V | 20 panels |
| **25 C (77 F STC)** | 45.25 V | 13 panels | 588.2 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 132HC-470 M10 SL?

Competing CEC solar panels closest to Heliene 132HC-470 M10 SL in nameplate wattage and Voc, starting with Auxin Solar AXN10M470W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN10M470W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m470w/) Auxin Solar | 470.0 W | Tie (0 W) | 43.78 V | 21.86% | 92.0% |
| [**Auxin Solar AXN10M465B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m465b/) Auxin Solar | 465.0 W | -5.0 W | 43.72 V | 21.63% | 91.6% |
| [**Aptos Solar Technology LLC DNA-120-BFN10-470W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bfn10-470w-dg/) Aptos Solar Technology LLC | 470.0 W | Tie (0 W) | 42.38 V | 21.76% | 94.9% |
| [**CSI Solar Co Ltd CS61-60TM-470H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-60tm-470h/) CSI Solar Co Ltd | 470.0 W | Tie (0 W) | 42.0 V | 21.46% | 94.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 132HC-470 M10 SL?

Evaluate Heliene 132HC-470 M10 SL (470.0 W STC, 45.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 132HC-470 M10 SL reaches 50.34 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (444 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 132HC-470 M10 SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 132HC-470 M10 SL 8 kW Residential Fit

Needs 18 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN10M470W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 442.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 132HC-470 M10 SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Heliene 132HC-470 M10 SL?

Multiplying Heliene 132HC-470 M10 SL's 13.21 A short-circuit current by 1.56 equals 20.61 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Heliene 132HC-470 M10 SL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.21 V cold Voc at 14 F and handles 13.21 A Isc; string inverters cap Heliene 132HC-470 M10 SL at 12 panels on 600 V.

### Is Heliene 132HC-470 M10 SL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 132HC-470 M10 SL rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

## Related Pages

Compare Heliene equipment, Auxin Solar AXN10M470W specs, utility payback rates, and NEC string calculators alongside Heliene 132HC-470 M10 SL.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)