title: "Heliene 120HC-380 Specs (380.0W, 41.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/heliene/heliene-120hc-380/
description: "CEC datasheet for Heliene 120HC-380: 380.0W STC, 41.6V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Heliene 120HC-380 — CEC Solar Module Specifications

Manufacturer: [**Heliene**](https://epri-peac.com/solar-equipment/brands/heliene/) Registry: **CEC Verified Engineering Specification**

Heliene 120HC-380 is a 380.0 W STC (356.7 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.77% efficiency, 41.6 V Voc at 25 C, and 45.55 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 380.0 W

- **PTC Wattage** : 356.7 W

- **Voc @ 25C** : 41.6 V

- **Efficiency** : 20.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 120HC-380 Compare Against Peer CEC Listings?

How Heliene Heliene 120HC-380 handles rooftop heat (356.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Heliene 120HC-380 exhibits 11.92 A short-circuit current, requiring a 18.6 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,043 of 21,677 (30.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 40.3 m2 for an 8 kW system (27 panels for 10 kW). Mid-range 41.6 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does Heliene 120HC-380 Fall Across Listed CEC Models?

Where Heliene 120HC-380 (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 120HC-380?

Percentile placement of Heliene 120HC-380 across power density (207.7 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for Heliene 120HC-380?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 120HC-380 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #11,043 / 21,677

### 380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,352

### 20.77% Aperture Efficiency

Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.55 V at -10 C (592.1 V string) and 46.67 V at -20 C (12 max).

 8 kW Reference Array

### 22 Panels = 8,360 W STC

Occupies 40.3 m2 (433 sq ft) producing 7,847 W PTC; NEC 690.8 OCPD floor is 18.6 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.6 * (1 + (-0.271/100) * (-10 - 25)) = 45.55 V | OCPD = 1.56 * 11.92 = 18.6 A

Inputs from CEC Modules.csv for Heliene 120HC-380: Voc=41.6 V, beta_Voc=-0.271%/C, Isc=11.92 A, STC=380.0 W, Area=1.83 m2.

**Result:** 13 panels max on 600 V (592.1 V); 22 panels for 8 kW (433 sq ft).

## What Are the Published CEC Specifications for Heliene 120HC-380?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 120HC-380. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Heliene 120HC-380.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 356.7 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.4 V / 10.75 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.271 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.77% (1.83 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Heliene 120HC-380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 120HC-380 (380.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 22 | 8.36 kW | 433 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 27 | 10.26 kW | 532 sq ft | $2,568 | $4,342 |

## Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 120HC-380 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Heliene 120HC-380 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Heliene 120HC-375** | 375.0 W | 351.9 W | 41.4 V | 35.26 V | 20.49% |
| **Heliene 120HC-380** | 380.0 W | 356.7 W | 41.6 V | 35.4 V | 20.77% |

## How Many Heliene 120HC-380 Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 120HC-380 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.6V and beta_Voc=-0.271%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.67 V | 12 panels | 560.0 V | 21 panels |
| **-10 C (14 F)** | 45.55 V | 13 panels | 592.1 V | 21 panels |
| **0 C (32 F)** | 44.42 V | 13 panels | 577.5 V | 22 panels |
| **25 C (77 F STC)** | 41.6 V | 14 panels | 582.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 120HC-380?

Alternative CEC solar modules from competing brands near Heliene 120HC-380 (380.0 W), including DualSun SAS DualSun 380M-120-01. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DualSun SAS DualSun 380M-120-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-380m-120-01/) DualSun SAS | 380.0 W | Tie (0 W) | 41.3 V | 21.47% | 93.9% |
| [**Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-380s-h-hc/) Boviet Solar Technology Co Ltd | 380.0 W | Tie (0 W) | 40.94 V | 20.54% | 94.2% |
| [**CSI Solar Co Ltd CS3L-385MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3l-385ms/) CSI Solar Co Ltd | 385.0 W | +5.0 W | 41.4 V | 21.51% | 93.2% |
| [**CSI Solar Co Ltd CS3L-375P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3l-375p/) CSI Solar Co Ltd | 375.0 W | -5.0 W | 41.2 V | 20.95% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 120HC-380?

Evaluate Heliene 120HC-380 (380.0 W STC, 41.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 120HC-380 reaches 46.67 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 120HC-380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 120HC-380 8 kW Residential Fit

Needs 22 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 120HC-380 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

### Why is Heliene 120HC-380 PTC wattage (356.7 W) lower than STC (380.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 356.7 W PTC (93.9% retention) across Heliene 120HC-380's 1.83 m2 aperture.

### Who should skip Heliene 120HC-380 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Heliene 120HC-380 panels (433 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 380M-120-01.

### What is the 1,000 V commercial string limit for Heliene 120HC-380?

On 1,000 V commercial inverters at -10 C (45.55 V cold Voc), Heliene 120HC-380 fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 120HC-380.

## Related Pages

Compare Heliene equipment, DualSun SAS DualSun 380M-120-01 specs, utility payback rates, and NEC string calculators alongside Heliene 120HC-380.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)