Heliene 108HC-415 M10 NTYP SL is a 415.0 W STC (391.7 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 38.02 V Voc at 25 C, and 41.2 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 415.0 W

- **PTC Wattage** : 391.7 W

- **Voc @ 25C** : 38.02 V

- **Efficiency** : 21.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Heliene 108HC-415 M10 NTYP SL Compare Against Peer CEC Listings?

How Heliene Heliene 108HC-415 M10 NTYP SL handles rooftop heat (391.7 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 108HC-415 M10 NTYP SL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). Compared against AXITEC AC-415TGB/108BB (415.0 W), this model holds strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Lower 38.02 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.7 A overcurrent floor served by a 25 A breaker.

## Where Does Heliene 108HC-415 M10 NTYP SL Fall Across Listed CEC Models?

Where Heliene 108HC-415 M10 NTYP SL (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Heliene 108HC-415 M10 NTYP SL?

Percentile placement of Heliene 108HC-415 M10 NTYP SL across power density (212.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Heliene 108HC-415 M10 NTYP SL?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 108HC-415 M10 NTYP SL specifications.

Rank #8,199 / 21,677

### Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,257

### 21.28% Aperture Efficiency

Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.2 V at -10 C (576.8 V string) and 42.11 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,300 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 21.7 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.02 * (1 + (-0.239/100) * (-10 - 25)) = 41.2 V | OCPD = 1.56 * 13.91 = 21.7 A

Inputs from CEC Modules.csv for Heliene 108HC-415 M10 NTYP SL: Voc=38.02 V, beta_Voc=-0.239%/C, Isc=13.91 A, STC=415.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (576.8 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for Heliene 108HC-415 M10 NTYP SL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 108HC-415 M10 NTYP SL.

Official California Energy Commission (NREL SAM) test parameters for Heliene 108HC-415 M10 NTYP SL.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 391.7 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.02 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.65 V / 13.13 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.239 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.28% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Heliene 108HC-415 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 108HC-415 M10 NTYP SL (415.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.22 kW | 315 sq ft | $1,557 | $2,632 |
| **8 kW Class** | 20 | 8.3 kW | 420 sq ft | $2,077 | $3,513 |
| **10 kW Class** | 25 | 10.38 kW | 525 sq ft | $2,598 | $4,393 |

## How Many Heliene 108HC-415 M10 NTYP SL Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 108HC-415 M10 NTYP SL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.02V and beta_Voc=-0.239%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.11 V | 14 panels | 589.5 V | 23 panels |
| **-10 C (14 F)** | 41.2 V | 14 panels | 576.8 V | 24 panels |
| **0 C (32 F)** | 40.29 V | 14 panels | 564.1 V | 24 panels |
| **25 C (77 F STC)** | 38.02 V | 15 panels | 570.3 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Heliene 108HC-415 M10 NTYP SL?

Alternative CEC solar modules from competing brands near Heliene 108HC-415 M10 NTYP SL (415.0 W), including AXITEC AC-415TGB/108BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-415TGB/108BB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-415tgb-108bb/) AXITEC | 415.0 W | Tie (0 W) | 38.04 V | 21.84% | 94.9% |
| [**Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mf10-415w-usaptos1a/) Aptos Solar Technology LLC | 415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| [**Boviet Solar Technology Co Ltd BVM7609M-415-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-415-h-hc/) Boviet Solar Technology Co Ltd | 415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| [**Aptos Solar Technology LLC DNA-108-BF10-415W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bf10-415w/) Aptos Solar Technology LLC | 415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Heliene 108HC-415 M10 NTYP SL?

Evaluate Heliene 108HC-415 M10 NTYP SL (415.0 W STC, 38.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Heliene 108HC-415 M10 NTYP SL reaches 42.11 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 108HC-415 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Heliene 108HC-415 M10 NTYP SL 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-415TGB/108BB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 108HC-415 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Heliene 108HC-415 M10 NTYP SL?

Multiplying Heliene 108HC-415 M10 NTYP SL's 13.91 A short-circuit current by 1.56 equals 21.7 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Heliene 108HC-415 M10 NTYP SL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.2 V cold Voc at 14 F and handles 13.91 A Isc; string inverters cap Heliene 108HC-415 M10 NTYP SL at 14 panels on 600 V.

### Is Heliene 108HC-415 M10 NTYP SL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 108HC-415 M10 NTYP SL rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.

## Related Pages

Compare Heliene equipment, AXITEC AC-415TGB/108BB specs, utility payback rates, and NEC string calculators alongside Heliene 108HC-415 M10 NTYP SL.

[All Heliene Certified Solar Models](https://epri-peac.com/solar-equipment/brands/heliene/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Heliene

- [All Heliene Specs](https://epri-peac.com/solar-equipment/brands/heliene/)
- [Heliene 156HC-645 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-645-m10-ntyp-sl-bifacial/)
- [Heliene 156HC-630 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-630-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl/)
- [Heliene 156HC-615 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/)
- [Heliene 144HC-585 M10 NTYP SL Bifacial](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-585-m10-ntyp-sl-bifacial/)