title: "HD HYUNDAI ENERGY SOLUTIONS CO Specs (635.0W, 57.56V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t635nj/
description: "CEC datasheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ: 635.0W STC, 57.56V Voc, 13-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ — CEC Solar Module Specifications

Manufacturer: [**HD HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ is a 635.0 W STC (600.7 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 23.01% efficiency, 57.56 V Voc at 25 C, and 62.25 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 635.0 W

- **PTC Wattage** : 600.7 W

- **Voc @ 25C** : 57.56 V

- **Efficiency** : 23.01%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ Compare Against Peer CEC Listings?

Solar engineering breakdown for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from HD HYUNDAI ENERGY SOLUTIONS CO LTD and peers, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ stands 225.0 W above the 410.0 W Mono-c-Si median and strong 94.6% PTC-to-STC heat retention (#2,348 of 21,677). Sizing 6 kW (10 panels) to 10 kW (16 panels) yields $1,589-$2,543/yr in baseline US bill offset. Higher 57.56 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).

## Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ Fall Across Listed CEC Models?

Distribution marker showing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ (635.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ?

Dataset percentiles tracking HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ?

Benchmark highlights for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #710 / 21,677

### Top 3.6% STC Output

635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,155

### 23.01% Aperture Efficiency

Power density 230.1 W/m2 (3.10 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 62.25 V at -10 C (560.2 V string) and 63.6 V at -20 C (9 max).

 8 kW Reference Array

### 13 Panels = 8,255 W STC

Occupies 35.9 m2 (386 sq ft) producing 7,809 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 57.56 * (1 + (-0.233/100) * (-10 - 25)) = 62.25 V | OCPD = 1.56 * 13.98 = 21.81 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ: Voc=57.56 V, beta_Voc=-0.233%/C, Isc=13.98 A, STC=635.0 W, Area=2.76 m2.

**Result:** 9 panels max on 600 V (560.2 V); 13 panels for 8 kW (386 sq ft).

## What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ?

Official CEC datasheet figures for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 600.7 W (94.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 57.56 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 47.57 V / 13.35 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.233 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.01% (2.76 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.35 kW | 297 sq ft | $1,589 | $2,687 |
| **8 kW Class** | 13 | 8.26 kW | 386 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 16 | 10.16 kW | 475 sq ft | $2,543 | $4,300 |

## Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HD HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ mechanical and cell layout.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T625NJ** | 625.0 W | 591.0 W | 57.15 V | 47.24 V | 22.64% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T630NJ** | 630.0 W | 595.9 W | 57.36 V | 47.41 V | 22.83% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ** | 635.0 W | 600.7 W | 57.56 V | 47.57 V | 23.01% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T640NJ** | 640.0 W | 605.6 W | 57.77 V | 47.74 V | 23.19% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T645NJ** | 645.0 W | 610.4 W | 57.97 V | 47.9 V | 23.37% |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ (62.25 V at 14 F).

Computed from Voc=57.56V and beta_Voc=-0.233%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 63.6 V | 9 panels | 572.4 V | 15 panels |
| **-10 C (14 F)** | 62.25 V | 9 panels | 560.2 V | 16 panels |
| **0 C (32 F)** | 60.91 V | 9 panels | 548.2 V | 16 panels |
| **25 C (77 F STC)** | 57.56 V | 10 panels | 575.6 V | 17 panels |

## Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ?

Competing CEC solar panels closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ in nameplate wattage and Voc, starting with Hengdian Group DMEGC Magnetics Co Ltd DM635M10T-B78yyy.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hengdian Group DMEGC Magnetics Co Ltd DM635M10T-B78yyy**](https://epri-peac.com/solar-equipment/modules/hengdian-group-dmegc-magnetics-co-ltd/hengdian-group-dmegc-magnetics-co-ltd-dm635m10t-b78yyy/) Hengdian Group DMEGC Magnetics Co Ltd | 635.0 W | Tie (0 W) | 57.5 V | 22.76% | 94.1% |
| [**AEG SOLAR ENERGY SRL ALPS78D30-635/TP**](https://epri-peac.com/solar-equipment/modules/aeg-solar-energy-srl/aeg-solar-energy-srl-alps78d30-635-tp/) AEG SOLAR ENERGY SRL | 635.0 W | Tie (0 W) | 57.15 V | 22.76% | 94.4% |
| [**G-Star Pte Ltd GSD7S78T-635BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd7s78t-635bt/) G-Star Pte Ltd | 635.0 W | Tie (0 W) | 57.12 V | 22.92% | 95.2% |
| [**G-Star Pte Ltd GSD7S78T-635WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd7s78t-635wt/) G-Star Pte Ltd | 635.0 W | Tie (0 W) | 57.12 V | 22.92% | 95.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ (635.0 W STC, 57.56 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ reaches 63.6 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ 8 kW Residential Fit

Needs 13 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hengdian Group DMEGC Magnetics Co Ltd DM635M10T-B78yyy.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 600.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ?

Multiplying HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ's 13.98 A short-circuit current by 1.56 equals 21.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 62.25 V cold Voc at 14 F and handles 13.98 A Isc; string inverters cap HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ at 9 panels on 600 V.

### Is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare HD HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Hengdian Group DMEGC Magnetics Co Ltd DM635M10T-B78yyy specs, utility payback rates, and NEC string calculators alongside HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ.

[All HD HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HD HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HD HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t640nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T620NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t620nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t600ni/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s600oj/)