title: "HD HYUNDAI ENERGY SOLUTIONS CO Specs (570.0W, 53.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s570oj/
description: "CEC datasheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ: 570.0W STC, 53.2V Voc, 15-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ — CEC Solar Module Specifications

Manufacturer: [**HD HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ is a 570.0 W STC (531.3 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 20.65% efficiency, 53.2 V Voc at 25 C, and 57.78 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 570.0 W

- **PTC Wattage** : 531.3 W

- **Voc @ 25C** : 53.2 V

- **Efficiency** : 20.65%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ Compare Against Peer CEC Listings?

How HD HYUNDAI ENERGY SOLUTIONS CO LTD HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ handles rooftop heat (531.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ exhibits 13.32 A short-circuit current, requiring a 20.78 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,154 of 21,677 (160.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 41.4 m2 for an 8 kW system (18 panels for 10 kW). Higher 53.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ Fall Across Listed CEC Models?

Where HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ (570.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ?

Percentile placement of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ across power density (206.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ?

Four critical engineering numbers homeowners and solar installers check first when reviewing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ specifications.

Rank #2,154 / 21,677

### Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,939

### 20.65% Aperture Efficiency

Power density 206.5 W/m2 (0.74 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.78 V at -10 C (577.8 V string) and 59.09 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,550 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,970 W PTC; NEC 690.8 OCPD floor is 20.78 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.2 * (1 + (-0.246/100) * (-10 - 25)) = 57.78 V | OCPD = 1.56 * 13.32 = 20.78 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ: Voc=53.2 V, beta_Voc=-0.246%/C, Isc=13.32 A, STC=570.0 W, Area=2.76 m2.

**Result:** 10 panels max on 600 V (577.8 V); 15 panels for 8 kW (446 sq ft).

## What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 570.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 531.3 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 45.4 V / 12.56 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.246 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.65% (2.76 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ (570.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.27 kW | 327 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 15 | 8.55 kW | 446 sq ft | $2,140 | $3,619 |
| **10 kW Class** | 18 | 10.26 kW | 535 sq ft | $2,568 | $4,342 |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ Modules Fit in a Cold-Weather String?

Maximum series module counts for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.2V and beta_Voc=-0.246%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.09 V | 10 panels | 590.9 V | 16 panels |
| **-10 C (14 F)** | 57.78 V | 10 panels | 577.8 V | 17 panels |
| **0 C (32 F)** | 56.47 V | 10 panels | 564.7 V | 17 panels |
| **25 C (77 F STC)** | 53.2 V | 11 panels | 585.2 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ?

Alternative CEC solar modules from competing brands near HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ (570.0 W), including Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7613m-570-h-hc-bf/) Boviet Solar Technology Co Ltd | 570.0 W | Tie (0 W) | 53.83 V | 20.36% | 93.9% |
| [**Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7613m-570-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 570.0 W | Tie (0 W) | 53.83 V | 20.36% | 94.1% |
| [**CSI Solar Co Ltd CS6W-570TB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-570tb-ag/) CSI Solar Co Ltd | 570.0 W | Tie (0 W) | 51.8 V | 22.71% | 94.9% |
| [**FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-565**](https://epri-peac.com/solar-equipment/modules/fs-green-energies-private-limited/fs-green-energies-private-limited-fst-m10144g-565/) FS GREEN ENERGIES PRIVATE LIMITED | 565.0 W | -5.0 W | 52.3 V | 22.07% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ (570.0 W STC, 53.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ reaches 59.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 446 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ 8 kW Residential Fit

Needs 15 modules (446 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 531.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ PTC wattage (531.3 W) lower than STC (570.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 531.3 W PTC (93.2% retention) across HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ's 2.76 m2 aperture.

### Who should skip HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ panels (446 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF.

### What is the 1,000 V commercial string limit for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ?

On 1,000 V commercial inverters at -10 C (57.78 V cold Voc), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ fits up to 17 panels per series string.

## Related Pages

Compare HD HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF specs, utility payback rates, and NEC string calculators alongside HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ.

[All HD HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HD HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HD HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t640nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t635nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T620NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t620nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t600ni/)