title: "HD HYUNDAI ENERGY SOLUTIONS CO Specs (410.0W, 45.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s410xh-bk/
description: "CEC datasheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK): 410.0W STC, 45.9V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) — CEC Solar Module Specifications

Manufacturer: [**HD HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) is a 410.0 W STC (383.5 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.53% efficiency, 45.9 V Voc at 25 C, and 49.71 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 383.5 W

- **Voc @ 25C** : 45.9 V

- **Efficiency** : 20.53%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) Compare Against Peer CEC Listings?

Solar engineering breakdown for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK): PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from HD HYUNDAI ENERGY SOLUTIONS CO LTD and peers, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) stands equal to the 410.0 W Mono-c-Si median and strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Mid-range 45.9 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

## Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) Fall Across Listed CEC Models?

Distribution marker showing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) (410.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)?

Dataset percentiles tracking HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)?

Benchmark highlights for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,442

### 20.53% Aperture Efficiency

Power density 205.3 W/m2 (0.62 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.71 V at -10 C (596.5 V string) and 50.8 V at -20 C (11 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 39.9 m2 (430 sq ft) producing 7,670 W PTC; NEC 690.8 OCPD floor is 17.78 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.9 * (1 + (-0.237/100) * (-10 - 25)) = 49.71 V | OCPD = 1.56 * 11.4 = 17.78 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK): Voc=45.9 V, beta_Voc=-0.237%/C, Isc=11.4 A, STC=410.0 W, Area=1.997 m2.

**Result:** 12 panels max on 600 V (596.5 V); 20 panels for 8 kW (430 sq ft).

## What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)?

Official CEC datasheet figures for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 383.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.1 V / 10.76 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.237 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.53% (1.997 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 322 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 430 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 537 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HD HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) mechanical and cell layout.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400XH(BK)** | 400.0 W | 373.9 W | 45.3 V | 37.7 V | 20.0% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405XH(BK)** | 405.0 W | 378.7 W | 45.6 V | 37.9 V | 20.28% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)** | 410.0 W | 383.5 W | 45.9 V | 38.1 V | 20.53% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S415XH(BK)** | 415.0 W | 388.3 W | 46.1 V | 38.4 V | 20.75% |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) (49.71 V at 14 F).

Computed from Voc=45.9V and beta_Voc=-0.237%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.8 V | 11 panels | 558.8 V | 19 panels |
| **-10 C (14 F)** | 49.71 V | 12 panels | 596.5 V | 20 panels |
| **0 C (32 F)** | 48.62 V | 12 panels | 583.4 V | 20 panels |
| **25 C (77 F STC)** | 45.9 V | 13 panels | 596.7 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)?

Competing CEC solar panels closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-410MS {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3N-410MS {Blk}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3n-410ms-blk/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 44.9 V | 20.81% | 93.5% |
| [**CSI Solar Co Ltd CS3W-410P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-410p/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 47.6 V | 19.16% | 93.2% |
| [**CSI Solar Co Ltd CS3N-405MS {Wht}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3n-405ms-wht/) CSI Solar Co Ltd | 405.0 W | -5.0 W | 44.7 V | 20.56% | 93.5% |
| [**AXITEC AC-410MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mh-144v/) AXITEC | 410.0 W | Tie (0 W) | 48.91 V | 20.71% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) (410.0 W STC, 45.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) reaches 50.8 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 430 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (430 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) 8 kW Residential Fit

Needs 20 modules (430 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-410MS {Blk}.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)?

Multiplying HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK)'s 11.4 A short-circuit current by 1.56 equals 17.78 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.71 V cold Voc at 14 F and handles 11.4 A Isc; string inverters cap HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) at 12 panels on 600 V.

### Is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK) rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

## Related Pages

Compare HD HYUNDAI ENERGY SOLUTIONS CO LTD equipment, CSI Solar Co Ltd CS3N-410MS {Blk} specs, utility payback rates, and NEC string calculators alongside HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK).

[All HD HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HD HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HD HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t640nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t635nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T620NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t620nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t600ni/)