title: "HD HYUNDAI ENERGY SOLUTIONS CO Specs (395.0W, 37.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s395of-bk/
description: "CEC datasheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK): 395.0W STC, 37.2V Voc, 21-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) — CEC Solar Module Specifications

Manufacturer: [**HD HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) is a 395.0 W STC (369.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 37.2 V Voc at 25 C, and 40.32 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 369.1 W

- **Voc @ 25C** : 37.2 V

- **Efficiency** : 20.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) Compare Against Peer CEC Listings?

Engineering position of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) (395.0 W STC) vs. Auxin Solar AXN10M395B across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Lower 37.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677), 21 panels occupy 441 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) Fall Across Listed CEC Models?

Plots HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK)?

Benchmarks HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) on STC wattage, thermal PTC/STC retention, and 20.26 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

### 20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.32 V at -10 C (564.5 V string) and 41.22 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,751 W PTC; NEC 690.8 OCPD floor is 20.56 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.2 * (1 + (-0.24/100) * (-10 - 25)) = 40.32 V | OCPD = 1.56 * 13.18 = 20.56 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK): Voc=37.2 V, beta_Voc=-0.24%/C, Isc=13.18 A, STC=395.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (564.5 V); 21 panels for 8 kW (441 sq ft).

## What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK)?

Laboratory test ratings recorded for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 369.1 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.18 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.7 V / 12.45 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.24 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.26% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (441 sq ft at 8 kW), and estimated Year-1 electric bill offset for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) (beta_Voc -0.24%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.2V and beta_Voc=-0.24%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.22 V | 14 panels | 577.1 V | 24 panels |
| **-10 C (14 F)** | 40.32 V | 14 panels | 564.5 V | 24 panels |
| **0 C (32 F)** | 39.43 V | 15 panels | 591.5 V | 25 panels |
| **25 C (77 F STC)** | 37.2 V | 16 panels | 595.2 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK)?

Closest cross-brand CEC competitors to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) matched near 395.0 W STC and 37.2 V Voc, led by Auxin Solar AXN10M395B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN10M395B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m395b/) Auxin Solar | 395.0 W | Tie (0 W) | 37.03 V | 20.84% | 93.9% |
| [**Convalt Manufacturing LLC CVLT395-108M-BB**](https://epri-peac.com/solar-equipment/modules/convalt-manufacturing-llc/convalt-manufacturing-llc-cvlt395-108m-bb/) Convalt Manufacturing LLC | 395.0 W | Tie (0 W) | 37.03 V | 20.36% | 91.9% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-395**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-395/) Elin Energy (Sirius PV) | 395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-395**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-395/) Elin Energy (Sirius PV) | 395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK)?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) (395.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) reaches 41.22 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M395B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) panels fit on a 600 V winter solar string?

At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) cold Voc rises from 37.2 V to 40.32 V (beta_Voc -0.24%/C), capping a 600 V string at 14 panels (564.5 V).

### How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) need?

An 8 kW DC system uses 21 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) modules (8,295 W STC / 7,751 W PTC), covering roughly 441 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

### How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) compare against Auxin Solar AXN10M395B?

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK) outputs 395.0 W STC (37.2 V Voc, rank #9,869 of 21,677), while Auxin Solar AXN10M395B delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HD HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Auxin Solar AXN10M395B specs, utility payback rates, and NEC string calculators alongside HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK).

[All HD HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HD HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HD HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t640nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t635nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T620NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t620nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t600ni/)