title: "HD HYUNDAI ENERGY SOLUTIONS CO Specs (640.0W, 56.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t640nj/
description: "CEC datasheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ: 640.0W STC, 56.3V Voc, 13-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ — CEC Solar Module Specifications

Manufacturer: [**HD HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ is a 640.0 W STC (610.6 W PTC) Mono-c-Si solar module ranking #638 of 21,677 CEC listings (top 3.3%; higher than 96.7% of peers). It delivers 23.1% efficiency, 56.3 V Voc at 25 C, and 60.77 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 640.0 W

- **PTC Wattage** : 610.6 W

- **Voc @ 25C** : 56.3 V

- **Efficiency** : 23.1%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (Mono-c-Si) residential solar systems.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ delivers 231.0 W/m2 (3.19 percentage points above 19.91% CEC median) and strong 95.4% PTC-to-STC heat retention (#141 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 62.05 V per unit, capping 600 V circuits at 9 panels. Compare specs directly with Bluesun Solar CoLtd BSM640M10-78HNH (640.0 W).

## Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Fall Across Listed CEC Models?

Comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (640.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Relative ranking of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ across nameplate watts, 95.4% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Summary of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ output rank, 8 kW array size (13 panels), efficiency rating, and 600 V string limit.

Rank #638 / 21,677

### Top 3.3% STC Output

640.0 W STC (+255.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #985

### 23.1% Aperture Efficiency

Power density 231.0 W/m2 (3.19 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.77 V at -10 C (546.9 V string) and 62.05 V at -20 C (9 max).

 8 kW Reference Array

### 13 Panels = 8,320 W STC

Occupies 36.0 m2 (388 sq ft) producing 7,938 W PTC; NEC 690.8 OCPD floor is 22.48 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 56.3 * (1 + (-0.227/100) * (-10 - 25)) = 60.77 V | OCPD = 1.56 * 14.41 = 22.48 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ: Voc=56.3 V, beta_Voc=-0.227%/C, Isc=14.41 A, STC=640.0 W, Area=2.77 m2.

**Result:** 9 panels max on 600 V (546.9 V); 13 panels for 8 kW (388 sq ft).

## What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Complete CEC test sheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ including Isc (14.41 A), Voc (56.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 640.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 610.6 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 56.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.9 V / 13.65 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.227 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.1% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.4 kW | 298 sq ft | $1,602 | $2,709 |
| **8 kW Class** | 13 | 8.32 kW | 388 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 16 | 10.24 kW | 477 sq ft | $2,563 | $4,334 |

## Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HD HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ series guide.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T630NJ** | 630.0 W | 600.9 W | 55.9 V | 46.5 V | 22.74% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T635NJ** | 635.0 W | 605.8 W | 56.1 V | 46.7 V | 22.92% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ** | 640.0 W | 610.6 W | 56.3 V | 46.9 V | 23.1% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T645NJ** | 645.0 W | 615.5 W | 56.5 V | 47.1 V | 23.29% |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (56.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=56.3V and beta_Voc=-0.227%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 62.05 V | 9 panels | 558.4 V | 16 panels |
| **-10 C (14 F)** | 60.77 V | 9 panels | 546.9 V | 16 panels |
| **0 C (32 F)** | 59.5 V | 10 panels | 595.0 V | 16 panels |
| **25 C (77 F STC)** | 56.3 V | 10 panels | 563.0 V | 17 panels |

## Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Four comparable CEC modules such as Bluesun Solar CoLtd BSM640M10-78HNH (640.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bluesun Solar CoLtd BSM640M10-78HNH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm640m10-78hnh/) Bluesun Solar CoLtd | 640.0 W | Tie (0 W) | 56.2 V | 23.1% | 95.2% |
| [**Hanersun Energy Co Ltd HN18N-78HT635W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-78ht635w/) Hanersun Energy Co Ltd | 635.0 W | -5.0 W | 56.2 V | 23.26% | 95.0% |
| [**Hansol Technics Co Ltd HA635-AE-NNEA0**](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/) Hansol Technics Co Ltd | 635.0 W | -5.0 W | 56.1 V | 22.92% | 95.4% |
| [**New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10**](https://epri-peac.com/solar-equipment/modules/new-east-solar-energy-cambodia-coltd/new-east-solar-energy-cambodia-coltd-nese635-78thb-m10/) New East Solar Energy (Cambodia) CoLtd | 635.0 W | -5.0 W | 56.1 V | 22.92% | 95.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ (640.0 W STC, 56.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ reaches 62.05 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Bluesun Solar CoLtd BSM640M10-78HNH.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 610.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ panels fit on a 600 V winter solar string?

At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ cold Voc rises from 56.3 V to 60.77 V (beta_Voc -0.227%/C), capping a 600 V string at 9 panels (546.9 V).

### How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ need?

An 8 kW DC system uses 13 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ modules (8,320 W STC / 7,938 W PTC), covering roughly 388 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

### How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ compare against Bluesun Solar CoLtd BSM640M10-78HNH?

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ outputs 640.0 W STC (56.3 V Voc, rank #638 of 21,677), while Bluesun Solar CoLtd BSM640M10-78HNH delivers 640.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HD HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Bluesun Solar CoLtd BSM640M10-78HNH specs, utility payback rates, and NEC string calculators alongside HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ.

[All HD HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HD HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HD HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t635nj/)