title: "HD HYUNDAI ENERGY SOLUTIONS CO Specs (595.0W, 52.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t595ni/
description: "CEC datasheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI: 595.0W STC, 52.1V Voc, 14-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI — CEC Solar Module Specifications

Manufacturer: [**HD HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI is a 595.0 W STC (555.1 W PTC) Mono-c-Si solar module ranking #1,462 of 21,677 CEC listings (top 7.4%; higher than 92.6% of peers). It delivers 23.24% efficiency, 52.1 V Voc at 25 C, and 57.81 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 595.0 W

- **PTC Wattage** : 555.1 W

- **Voc @ 25C** : 52.1 V

- **Efficiency** : 23.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI (Mono-c-Si) residential solar systems.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI delivers 232.4 W/m2 (3.33 percentage points above 19.91% CEC median) and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 59.44 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Chint New Energy Technology Co Ltd CHSM72RN-HC-595 (595.0 W).

## Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI Fall Across Listed CEC Models?

Comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI (595.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI?

Relative ranking of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI?

Summary of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,462 / 21,677

### Top 7.4% STC Output

595.0 W STC (+210.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #810

### 23.24% Aperture Efficiency

Power density 232.4 W/m2 (3.33 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.81 V at -10 C (578.1 V string) and 59.44 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,330 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,771 W PTC; NEC 690.8 OCPD floor is 22.67 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.1 * (1 + (-0.313/100) * (-10 - 25)) = 57.81 V | OCPD = 1.56 * 14.53 = 22.67 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI: Voc=52.1 V, beta_Voc=-0.313%/C, Isc=14.53 A, STC=595.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (578.1 V); 14 panels for 8 kW (386 sq ft).

## What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI?

Complete CEC test sheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI including Isc (14.53 A), Voc (52.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 595.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 555.1 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.4 V / 13.72 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.313 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.24% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.54 kW | 303 sq ft | $1,637 | $2,768 |
| **8 kW Class** | 14 | 8.33 kW | 386 sq ft | $2,085 | $3,525 |
| **10 kW Class** | 17 | 10.12 kW | 468 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HD HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI series guide.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T590NI** | 590.0 W | 550.3 W | 51.9 V | 43.2 V | 23.05% |
| **HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI** | 595.0 W | 555.1 W | 52.1 V | 43.4 V | 23.24% |

## How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI (52.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.1V and beta_Voc=-0.313%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.44 V | 10 panels | 594.4 V | 16 panels |
| **-10 C (14 F)** | 57.81 V | 10 panels | 578.1 V | 17 panels |
| **0 C (32 F)** | 56.18 V | 10 panels | 561.8 V | 17 panels |
| **25 C (77 F STC)** | 52.1 V | 11 panels | 573.1 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI?

Four comparable CEC modules such as Chint New Energy Technology Co Ltd CHSM72RN-HC-595 (595.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Chint New Energy Technology Co Ltd CHSM72RN-HC-595**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72rn-hc-595/) Chint New Energy Technology Co Ltd | 595.0 W | Tie (0 W) | 51.2 V | 22.97% | 94.6% |
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) AXITEC | 590.0 W | -5.0 W | 51.7 V | 23.41% | 95.1% |
| [**Bluesun Solar CoLtd BSM590M10-72HNH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm590m10-72hnh/) Bluesun Solar CoLtd | 590.0 W | -5.0 W | 51.3 V | 23.05% | 95.2% |
| [**ELITE Solar ET-N772TBH585GB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n772tbh585gb/) ELITE Solar | 585.0 W | -10.0 W | 52.28 V | 22.67% | 94.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI (595.0 W STC, 52.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI reaches 59.44 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72RN-HC-595.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 555.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI panels fit on a 600 V winter solar string?

At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI cold Voc rises from 52.1 V to 57.81 V (beta_Voc -0.313%/C), capping a 600 V string at 10 panels (578.1 V).

### How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI need?

An 8 kW DC system uses 14 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI modules (8,330 W STC / 7,771 W PTC), covering roughly 386 sq ft and saving ~$2,085/yr at 18.54 c/kWh.

### How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI compare against Chint New Energy Technology Co Ltd CHSM72RN-HC-595?

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI outputs 595.0 W STC (52.1 V Voc, rank #1,462 of 21,677), while Chint New Energy Technology Co Ltd CHSM72RN-HC-595 delivers 595.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HD HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Chint New Energy Technology Co Ltd CHSM72RN-HC-595 specs, utility payback rates, and NEC string calculators alongside HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI.

[All HD HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HD HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HD HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hd-hyundai-energy-solutions-co-ltd/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t640nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t635nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T620NJ](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-t620nj/)
- [HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t600ni/)