CEC PV Module

# Hansol Technics Co Ltd HS345UD-AN1 {Wht} — CEC Solar Module Specifications

Manufacturer: [**Hansol Technics Co Ltd**](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hansol Technics Co Ltd HS345UD-AN1 {Wht} is a 345.0 W STC (315.3 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.78% efficiency, 46.4 V Voc at 25 C, and 50.96 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 345.0 W

- **PTC Wattage** : 315.3 W

- **Voc @ 25C** : 46.4 V

- **Efficiency** : 17.78%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hansol Technics Co Ltd HS345UD-AN1 {Wht} Compare Against Peer CEC Listings?

How Hansol Technics Co Ltd Hansol Technics Co Ltd HS345UD-AN1 {Wht} handles rooftop heat (315.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hansol Technics Co Ltd HS345UD-AN1 {Wht} exhibits 9.55 A short-circuit current, requiring a 14.9 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #13,309 of 21,677 (65.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 46.6 m2 for an 8 kW system (29 panels for 10 kW). Mid-range 46.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Hansol Technics Co Ltd HS345UD-AN1 {Wht} Fall Across Listed CEC Models?

Where Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Percentile placement of Hansol Technics Co Ltd HS345UD-AN1 {Wht} across power density (177.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS345UD-AN1 {Wht} specifications.

Rank #13,309 / 21,677

### 345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,390

### 17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.96 V at -10 C (560.6 V string) and 52.27 V at -20 C (11 max).

 8 kW Reference Array

### 24 Panels = 8,280 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,567 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.4 * (1 + (-0.281/100) * (-10 - 25)) = 50.96 V | OCPD = 1.56 * 9.55 = 14.9 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS345UD-AN1 {Wht}: Voc=46.4 V, beta_Voc=-0.281%/C, Isc=9.55 A, STC=345.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (560.6 V); 24 panels for 8 kW (501 sq ft).

## What Are the Published CEC Specifications for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS345UD-AN1 {Wht}.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS345UD-AN1 {Wht}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 315.3 W (91.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 46.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.6 V / 8.94 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.281 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.78% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hansol Technics Co Ltd HS345UD-AN1 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 18 | 6.21 kW | 376 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 24 | 8.28 kW | 501 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 29 | 10.01 kW | 606 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HS345UD-AN1 {Wht} architecture.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS345UD-AN1 {Wht} wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hansol Technics Co Ltd HS340UD-AN1 {Wht}** | 340.0 W | 310.6 W | 46.1 V | 38.3 V | 17.58% |
| **Hansol Technics Co Ltd HS345UD-AN1 {Wht}** | 345.0 W | 315.3 W | 46.4 V | 38.6 V | 17.78% |

## How Many Hansol Technics Co Ltd HS345UD-AN1 {Wht} Modules Fit in a Cold-Weather String?

Maximum series module counts for Hansol Technics Co Ltd HS345UD-AN1 {Wht} from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.4V and beta_Voc=-0.281%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.27 V | 11 panels | 575.0 V | 19 panels |
| **-10 C (14 F)** | 50.96 V | 11 panels | 560.6 V | 19 panels |
| **0 C (32 F)** | 49.66 V | 12 panels | 595.9 V | 20 panels |
| **25 C (77 F STC)** | 46.4 V | 12 panels | 556.8 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W), including GCL System Integration Technology Co Ltd GCL-M6/72345.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-M6/72345**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-72345/) GCL System Integration Technology Co Ltd | 345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
| [**GCL System Integration Technology Co Ltd GCL-P3/72H345**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p3-72h345/) GCL System Integration Technology Co Ltd | 345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| [**AXITEC AC-345M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-345m-156-72s/) AXITEC | 345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| [**GCL System Integration Technology Co Ltd GCL-P6/72345**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-72345/) GCL System Integration Technology Co Ltd | 345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Evaluate Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W STC, 46.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS345UD-AN1 {Wht} reaches 52.27 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS345UD-AN1 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hansol Technics Co Ltd HS345UD-AN1 {Wht} 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72345.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 315.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS345UD-AN1 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Hansol Technics Co Ltd HS345UD-AN1 {Wht} PTC wattage (315.3 W) lower than STC (345.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 315.3 W PTC (91.4% retention) across Hansol Technics Co Ltd HS345UD-AN1 {Wht}'s 1.94 m2 aperture.

### Who should skip Hansol Technics Co Ltd HS345UD-AN1 {Wht} on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Hansol Technics Co Ltd HS345UD-AN1 {Wht} panels (501 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/72345.

### What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

On 1,000 V commercial inverters at -10 C (50.96 V cold Voc), Hansol Technics Co Ltd HS345UD-AN1 {Wht} fits up to 19 panels per series string.

## Related Pages

Compare Hansol Technics Co Ltd equipment, GCL System Integration Technology Co Ltd GCL-M6/72345 specs, utility payback rates, and NEC string calculators alongside Hansol Technics Co Ltd HS345UD-AN1 {Wht}.

[All Hansol Technics Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hansol Technics Co Ltd

- [All Hansol Technics Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/)
- [Hansol Technics Co Ltd HA650-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/)
- [Hansol Technics Co Ltd HA635-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/)
- [Hansol Technics Co Ltd HA630AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha630ae-ngea0/)
- [Hansol Technics Co Ltd HA615-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615-ae-nnea0/)
- [Hansol Technics Co Ltd HA615AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615ae-ngea0/)