---
title: "Hansol Technics Co Ltd Specs (315.0W, 40.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-hs315ub-jh2-wht/
description: "CEC datasheet for Hansol Technics Co Ltd HS315UB-JH2 {Wht}: 315.0W STC, 40.4V Voc, 26-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hansol Technics Co Ltd HS315UB-JH2 {Wht} — CEC Solar Module Specifications

Manufacturer: [**Hansol Technics Co Ltd**](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hansol Technics Co Ltd HS315UB-JH2 {Wht} is a 315.0 W STC (294.9 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 19.55% efficiency, 40.4 V Voc at 25 C, and 44.36 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 315.0 W

- **PTC Wattage** : 294.9 W

- **Voc @ 25C** : 40.4 V

- **Efficiency** : 19.55%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hansol Technics Co Ltd HS315UB-JH2 {Wht} Compare Against Peer CEC Listings?

Engineering position of Hansol Technics Co Ltd HS315UB-JH2 {Wht} (315.0 W STC) vs. GCL System Integration Technology Co Ltd GCL-M6/60315 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Hansol Technics Co Ltd HS315UB-JH2 {Wht} pairs strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677) with 40.4 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,667 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer GCL System Integration Technology Co Ltd GCL-M6/60315 offers a 315.0 W alternative.

## Where Does Hansol Technics Co Ltd HS315UB-JH2 {Wht} Fall Across Listed CEC Models?

Plots Hansol Technics Co Ltd HS315UB-JH2 {Wht} at 315.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Hansol Technics Co Ltd HS315UB-JH2 {Wht}?

Benchmarks Hansol Technics Co Ltd HS315UB-JH2 {Wht} on STC wattage, thermal PTC/STC retention, and 19.55 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS315UB-JH2 {Wht}?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS315UB-JH2 {Wht} by Hansol Technics Co Ltd.

Rank #15,387 / 21,677

### 315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,012

### 19.55% Aperture Efficiency

Power density 195.5 W/m2 (0.36 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.36 V at -10 C (576.7 V string) and 45.49 V at -20 C (13 max).

 8 kW Reference Array

### 26 Panels = 8,190 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,667 W PTC; NEC 690.8 OCPD floor is 15.32 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.4 * (1 + (-0.28/100) * (-10 - 25)) = 44.36 V | OCPD = 1.56 * 9.82 = 15.32 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS315UB-JH2 {Wht}: Voc=40.4 V, beta_Voc=-0.28%/C, Isc=9.82 A, STC=315.0 W, Area=1.611 m2.

**Result:** 13 panels max on 600 V (576.7 V); 26 panels for 8 kW (451 sq ft).

## What Are the Published CEC Specifications for Hansol Technics Co Ltd HS315UB-JH2 {Wht}?

Laboratory test ratings recorded for Hansol Technics Co Ltd HS315UB-JH2 {Wht} (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS315UB-JH2 {Wht}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 294.9 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.82 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.3 V / 9.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.28 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.55% (1.611 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hansol Technics Co Ltd HS315UB-JH2 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (451 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS315UB-JH2 {Wht}.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.3 kW | 347 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 26 | 8.19 kW | 451 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 32 | 10.08 kW | 555 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS315UB-JH2 {Wht} under Hansol Technics Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS315UB-JH2 {Wht} wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hansol Technics Co Ltd HS305UB-JH2 {Wht}** | 305.0 W | 285.3 W | 40.0 V | 33.9 V | 18.93% |
| **Hansol Technics Co Ltd HS310UB-JH2 {Wht}** | 310.0 W | 290.1 W | 40.2 V | 34.1 V | 19.24% |
| **Hansol Technics Co Ltd HS315UB-JH2 {Wht}** | 315.0 W | 294.9 W | 40.4 V | 34.3 V | 19.55% |
| **Hansol Technics Co Ltd HS320UB-JH2 {Wht}** | 320.0 W | 299.7 W | 40.6 V | 34.5 V | 19.86% |

## How Many Hansol Technics Co Ltd HS315UB-JH2 {Wht} Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hansol Technics Co Ltd HS315UB-JH2 {Wht} (beta_Voc -0.28%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.4V and beta_Voc=-0.28%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.49 V | 13 panels | 591.4 V | 21 panels |
| **-10 C (14 F)** | 44.36 V | 13 panels | 576.7 V | 22 panels |
| **0 C (32 F)** | 43.23 V | 13 panels | 562.0 V | 23 panels |
| **25 C (77 F STC)** | 40.4 V | 14 panels | 565.6 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS315UB-JH2 {Wht}?

Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS315UB-JH2 {Wht} matched near 315.0 W STC and 40.4 V Voc, led by GCL System Integration Technology Co Ltd GCL-M6/60315.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-M6/60315**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60315/) GCL System Integration Technology Co Ltd | 315.0 W | Tie (0 W) | 40.1 V | 19.33% | 91.3% |
| [**AXITEC AC-315MH/120S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-315mh-120s/) AXITEC | 315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| [**AXITEC AC-315MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-315mh-120v/) AXITEC | 315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| [**CertainTeed CT315HC11-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct315hc11-04/) CertainTeed | 315.0 W | Tie (0 W) | 39.74 V | 19.58% | 92.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS315UB-JH2 {Wht}?

Evaluate Hansol Technics Co Ltd HS315UB-JH2 {Wht} (315.0 W STC, 40.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS315UB-JH2 {Wht} reaches 45.49 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (451 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS315UB-JH2 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hansol Technics Co Ltd HS315UB-JH2 {Wht} 8 kW Residential Fit

Needs 26 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60315.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 294.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS315UB-JH2 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS315UB-JH2 {Wht}?

Multiplying Hansol Technics Co Ltd HS315UB-JH2 {Wht}'s 9.82 A short-circuit current by 1.56 equals 15.32 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Hansol Technics Co Ltd HS315UB-JH2 {Wht} pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.36 V cold Voc at 14 F and handles 9.82 A Isc; string inverters cap Hansol Technics Co Ltd HS315UB-JH2 {Wht} at 13 panels on 600 V.

### Is Hansol Technics Co Ltd HS315UB-JH2 {Wht} eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS315UB-JH2 {Wht} rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Hansol Technics Co Ltd equipment, GCL System Integration Technology Co Ltd GCL-M6/60315 specs, utility payback rates, and NEC string calculators alongside Hansol Technics Co Ltd HS315UB-JH2 {Wht}.

[All Hansol Technics Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hansol Technics Co Ltd

- [All Hansol Technics Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/)
- [Hansol Technics Co Ltd HA650-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/)
- [Hansol Technics Co Ltd HA635-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/)
- [Hansol Technics Co Ltd HA630AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha630ae-ngea0/)
- [Hansol Technics Co Ltd HA615-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615-ae-nnea0/)
- [Hansol Technics Co Ltd HA615AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615ae-ngea0/)
