title: "Hansol Technics Co Ltd HS240ME-V01 Specs (240.0W, 37.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-hs240me-v01/
description: "CEC datasheet for Hansol Technics Co Ltd HS240ME-V01: 240.0W STC, 37.7V Voc, 34-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hansol Technics Co Ltd HS240ME-V01 — CEC Solar Module Specifications

Manufacturer: [**Hansol Technics Co Ltd**](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hansol Technics Co Ltd HS240ME-V01 is a 240.0 W STC (214.4 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.99% efficiency, 37.7 V Voc at 25 C, and 41.92 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 214.4 W

- **Voc @ 25C** : 37.7 V

- **Efficiency** : 14.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hansol Technics Co Ltd HS240ME-V01 Compare Against Peer CEC Listings?

Solar engineering breakdown for Hansol Technics Co Ltd HS240ME-V01: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS240ME-V01 stands 38.8 W below the 278.8 W Multi-c-Si median and typical 89.3% PTC-to-STC thermal output (214.4 W real-world rating). Sizing 6 kW (25 panels) to 10 kW (42 panels) yields $1,502-$2,523/yr in baseline US bill offset. Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Hansol Technics Co Ltd HS240ME-V01 Fall Across Listed CEC Models?

Distribution marker showing Hansol Technics Co Ltd HS240ME-V01 (240.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Hansol Technics Co Ltd HS240ME-V01?

Dataset percentiles tracking Hansol Technics Co Ltd HS240ME-V01 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS240ME-V01?

Benchmark highlights for Hansol Technics Co Ltd HS240ME-V01 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,754

### 14.99% Aperture Efficiency

Power density 149.9 W/m2 (4.92 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.92 V at -10 C (586.9 V string) and 43.13 V at -20 C (13 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 54.4 m2 (586 sq ft) producing 7,290 W PTC; NEC 690.8 OCPD floor is 12.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.7 * (1 + (-0.32/100) * (-10 - 25)) = 41.92 V | OCPD = 1.56 * 8.31 = 12.96 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS240ME-V01: Voc=37.7 V, beta_Voc=-0.32%/C, Isc=8.31 A, STC=240.0 W, Area=1.601 m2.

**Result:** 14 panels max on 600 V (586.9 V); 34 panels for 8 kW (586 sq ft).

## What Are the Published CEC Specifications for Hansol Technics Co Ltd HS240ME-V01?

Official CEC datasheet figures for Hansol Technics Co Ltd HS240ME-V01 (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS240ME-V01.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 214.4 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.3 V / 7.93 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.99% (1.601 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Hansol Technics Co Ltd HS240ME-V01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hansol Technics Co Ltd HS240ME-V01 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 431 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 586 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 724 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS240ME-V01 mechanical and cell layout.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS240ME-V01 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hansol Technics Co Ltd HS240ME-V01** | 240.0 W | 214.4 W | 37.7 V | 30.3 V | 14.99% |
| **Hansol Technics Co Ltd HS245ME-V01** | 245.0 W | 219.0 W | 37.8 V | 30.4 V | 15.31% |

## How Many Hansol Technics Co Ltd HS240ME-V01 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS240ME-V01 (41.92 V at 14 F).

Computed from Voc=37.7V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.13 V | 13 panels | 560.7 V | 23 panels |
| **-10 C (14 F)** | 41.92 V | 14 panels | 586.9 V | 23 panels |
| **0 C (32 F)** | 40.72 V | 14 panels | 570.1 V | 24 panels |
| **25 C (77 F STC)** | 37.7 V | 15 panels | 565.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS240ME-V01?

Competing CEC solar panels closest to Hansol Technics Co Ltd HS240ME-V01 in nameplate wattage and Voc, starting with Centrosolar America EP6 240 BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America EP6 240 BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-240-bw/) Centrosolar America | 240.0 W | Tie (0 W) | 37.64 V | 14.68% | 88.6% |
| [**Centrosolar America EP6 240 SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-240-sw/) Centrosolar America | 240.0 W | Tie (0 W) | 37.64 V | 14.68% | 88.6% |
| [**Heliene 60P240**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-60p240/) Heliene | 240.0 W | Tie (0 W) | 37.55 V | 14.62% | 89.2% |
| [**AXITEC AC-240M/156-60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-240m-156-60s/) AXITEC | 240.0 W | Tie (0 W) | 37.47 V | 14.79% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS240ME-V01?

Evaluate Hansol Technics Co Ltd HS240ME-V01 (240.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS240ME-V01 reaches 43.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 586 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (586 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS240ME-V01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hansol Technics Co Ltd HS240ME-V01 8 kW Residential Fit

Needs 34 modules (586 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America EP6 240 BW.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS240ME-V01 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS240ME-V01?

Multiplying Hansol Technics Co Ltd HS240ME-V01's 8.31 A short-circuit current by 1.56 equals 12.96 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Hansol Technics Co Ltd HS240ME-V01 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.92 V cold Voc at 14 F and handles 8.31 A Isc; string inverters cap Hansol Technics Co Ltd HS240ME-V01 at 14 panels on 600 V.

### Is Hansol Technics Co Ltd HS240ME-V01 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS240ME-V01 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

## Related Pages

Compare Hansol Technics Co Ltd equipment, Centrosolar America EP6 240 BW specs, utility payback rates, and NEC string calculators alongside Hansol Technics Co Ltd HS240ME-V01.

[All Hansol Technics Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hansol Technics Co Ltd

- [All Hansol Technics Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/)
- [Hansol Technics Co Ltd HA650-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/)
- [Hansol Technics Co Ltd HA635-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/)
- [Hansol Technics Co Ltd HA630AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha630ae-ngea0/)
- [Hansol Technics Co Ltd HA615-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615-ae-nnea0/)
- [Hansol Technics Co Ltd HA615AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615ae-ngea0/)