title: "Hansol Technics Co Ltd Specs (650.0W, 56.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/
description: "CEC datasheet for Hansol Technics Co Ltd HA650-AE-NNEA0: 650.0W STC, 56.7V Voc, 13-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hansol Technics Co Ltd HA650-AE-NNEA0 — CEC Solar Module Specifications

Manufacturer: [**Hansol Technics Co Ltd**](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hansol Technics Co Ltd HA650-AE-NNEA0 is a 650.0 W STC (620.3 W PTC) Mono-c-Si solar module ranking #512 of 21,677 CEC listings (top 2.6%; higher than 97.4% of peers). It delivers 23.47% efficiency, 56.7 V Voc at 25 C, and 61.2 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 650.0 W

- **PTC Wattage** : 620.3 W

- **Voc @ 25C** : 56.7 V

- **Efficiency** : 23.47%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hansol Technics Co Ltd HA650-AE-NNEA0 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HA650-AE-NNEA0 (Mono-c-Si) residential solar systems.

Hansol Technics Co Ltd HA650-AE-NNEA0 delivers 234.7 W/m2 (3.56 percentage points above 19.91% CEC median) and strong 95.4% PTC-to-STC heat retention (#141 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 62.49 V per unit, capping 600 V circuits at 9 panels. Compare specs directly with HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ (650.0 W).

## Where Does Hansol Technics Co Ltd HA650-AE-NNEA0 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HA650-AE-NNEA0 (650.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Hansol Technics Co Ltd HA650-AE-NNEA0?

Relative ranking of Hansol Technics Co Ltd HA650-AE-NNEA0 across nameplate watts, 95.4% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA650-AE-NNEA0?

Summary of Hansol Technics Co Ltd HA650-AE-NNEA0 output rank, 8 kW array size (13 panels), efficiency rating, and 600 V string limit.

Rank #512 / 21,677

### Top 2.6% STC Output

650.0 W STC (+265.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #537

### 23.47% Aperture Efficiency

Power density 234.7 W/m2 (3.56 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 61.2 V at -10 C (550.8 V string) and 62.49 V at -20 C (9 max).

 8 kW Reference Array

### 13 Panels = 8,450 W STC

Occupies 36.0 m2 (388 sq ft) producing 8,064 W PTC; NEC 690.8 OCPD floor is 22.64 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 56.7 * (1 + (-0.227/100) * (-10 - 25)) = 61.2 V | OCPD = 1.56 * 14.51 = 22.64 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA650-AE-NNEA0: Voc=56.7 V, beta_Voc=-0.227%/C, Isc=14.51 A, STC=650.0 W, Area=2.77 m2.

**Result:** 9 panels max on 600 V (550.8 V); 13 panels for 8 kW (388 sq ft).

## What Are the Published CEC Specifications for Hansol Technics Co Ltd HA650-AE-NNEA0?

Complete CEC test sheet for Hansol Technics Co Ltd HA650-AE-NNEA0 including Isc (14.51 A), Voc (56.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA650-AE-NNEA0.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 650.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 620.3 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 56.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 47.3 V / 13.75 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.227 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.47% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hansol Technics Co Ltd HA650-AE-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HA650-AE-NNEA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.5 kW | 298 sq ft | $1,627 | $2,751 |
| **8 kW Class** | 13 | 8.45 kW | 388 sq ft | $2,115 | $3,576 |
| **10 kW Class** | 16 | 10.4 kW | 477 sq ft | $2,603 | $4,402 |

## How Many Hansol Technics Co Ltd HA650-AE-NNEA0 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HA650-AE-NNEA0 (56.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=56.7V and beta_Voc=-0.227%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 62.49 V | 9 panels | 562.4 V | 16 panels |
| **-10 C (14 F)** | 61.2 V | 9 panels | 550.8 V | 16 panels |
| **0 C (32 F)** | 59.92 V | 10 panels | 599.2 V | 16 panels |
| **25 C (77 F STC)** | 56.7 V | 10 panels | 567.0 V | 17 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA650-AE-NNEA0?

Four comparable CEC modules such as HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ (650.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ**](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t650nj/) HD HYUNDAI ENERGY SOLUTIONS CO LTD | 650.0 W | Tie (0 W) | 56.7 V | 23.47% | 95.4% |
| [**New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10**](https://epri-peac.com/solar-equipment/modules/new-east-solar-energy-cambodia-coltd/new-east-solar-energy-cambodia-coltd-nese650-78thb-m10/) New East Solar Energy (Cambodia) CoLtd | 650.0 W | Tie (0 W) | 56.7 V | 23.47% | 95.4% |
| [**ELITE Solar ET-N778TBH655GB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n778tbh655gb/) ELITE Solar | 655.0 W | +5.0 W | 57.49 V | 23.39% | 95.1% |
| [**ELITE Solar ET-N778TBH655GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n778tbh655gl/) ELITE Solar | 655.0 W | +5.0 W | 57.49 V | 23.39% | 95.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA650-AE-NNEA0?

Evaluate Hansol Technics Co Ltd HA650-AE-NNEA0 (650.0 W STC, 56.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA650-AE-NNEA0 reaches 62.49 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA650-AE-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hansol Technics Co Ltd HA650-AE-NNEA0 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,115/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 620.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA650-AE-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Hansol Technics Co Ltd HA650-AE-NNEA0 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HA650-AE-NNEA0 cold Voc rises from 56.7 V to 61.2 V (beta_Voc -0.227%/C), capping a 600 V string at 9 panels (550.8 V).

### How much roof area does an 8 kW array of Hansol Technics Co Ltd HA650-AE-NNEA0 need?

An 8 kW DC system uses 13 Hansol Technics Co Ltd HA650-AE-NNEA0 modules (8,450 W STC / 8,064 W PTC), covering roughly 388 sq ft and saving ~$2,115/yr at 18.54 c/kWh.

### How does Hansol Technics Co Ltd HA650-AE-NNEA0 compare against HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ?

Hansol Technics Co Ltd HA650-AE-NNEA0 outputs 650.0 W STC (56.7 V Voc, rank #512 of 21,677), while HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ delivers 650.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Hansol Technics Co Ltd equipment, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ specs, utility payback rates, and NEC string calculators alongside Hansol Technics Co Ltd HA650-AE-NNEA0.

[All Hansol Technics Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hansol Technics Co Ltd

- [All Hansol Technics Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/)
- [Hansol Technics Co Ltd HA635-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/)
- [Hansol Technics Co Ltd HA630AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha630ae-ngea0/)
- [Hansol Technics Co Ltd HA615-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615-ae-nnea0/)
- [Hansol Technics Co Ltd HA615AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615ae-ngea0/)