---
title: "Hansol Technics Co Ltd Specs (635.0W, 56.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/
description: "CEC datasheet for Hansol Technics Co Ltd HA635-AE-NNEA0: 635.0W STC, 56.1V Voc, 13-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hansol Technics Co Ltd HA635-AE-NNEA0 — CEC Solar Module Specifications

Manufacturer: [**Hansol Technics Co Ltd**](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hansol Technics Co Ltd HA635-AE-NNEA0 is a 635.0 W STC (605.7 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 22.92% efficiency, 56.1 V Voc at 25 C, and 60.56 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 635.0 W

- **PTC Wattage** : 605.7 W

- **Voc @ 25C** : 56.1 V

- **Efficiency** : 22.92%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hansol Technics Co Ltd HA635-AE-NNEA0 Compare Against Peer CEC Listings?

How Hansol Technics Co Ltd Hansol Technics Co Ltd HA635-AE-NNEA0 handles rooftop heat (605.7 W PTC), 8 kW sizing, and cold winter string voltage.

Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HA635-AE-NNEA0 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 229.2 W/m2 (3.01 percentage points above 19.91% CEC median). Compared against New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 (635.0 W), this model holds strong 95.4% PTC-to-STC heat retention (#141 of 21,677). Higher 56.1 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C), while NEC 690.8 sets a 22.4 A overcurrent floor served by a 25 A breaker.

## Where Does Hansol Technics Co Ltd HA635-AE-NNEA0 Fall Across Listed CEC Models?

Where Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Hansol Technics Co Ltd HA635-AE-NNEA0?

Percentile placement of Hansol Technics Co Ltd HA635-AE-NNEA0 across power density (229.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA635-AE-NNEA0?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HA635-AE-NNEA0 specifications.

Rank #710 / 21,677

### Top 3.6% STC Output

635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,267

### 22.92% Aperture Efficiency

Power density 229.2 W/m2 (3.01 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.56 V at -10 C (545.0 V string) and 61.83 V at -20 C (9 max).

 8 kW Reference Array

### 13 Panels = 8,255 W STC

Occupies 36.0 m2 (388 sq ft) producing 7,874 W PTC; NEC 690.8 OCPD floor is 22.4 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 56.1 * (1 + (-0.227/100) * (-10 - 25)) = 60.56 V | OCPD = 1.56 * 14.36 = 22.4 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA635-AE-NNEA0: Voc=56.1 V, beta_Voc=-0.227%/C, Isc=14.36 A, STC=635.0 W, Area=2.77 m2.

**Result:** 9 panels max on 600 V (545.0 V); 13 panels for 8 kW (388 sq ft).

## What Are the Published CEC Specifications for Hansol Technics Co Ltd HA635-AE-NNEA0?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HA635-AE-NNEA0.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA635-AE-NNEA0.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 605.7 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 56.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.7 V / 13.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.227 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.92% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hansol Technics Co Ltd HA635-AE-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.35 kW | 298 sq ft | $1,589 | $2,687 |
| **8 kW Class** | 13 | 8.26 kW | 388 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 16 | 10.16 kW | 477 sq ft | $2,543 | $4,300 |

## Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HA635-AE-NNEA0 architecture.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HA635-AE-NNEA0 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hansol Technics Co Ltd HA625-AE-NNEA0** | 625.0 W | 596.0 W | 55.7 V | 46.3 V | 22.56% |
| **Hansol Technics Co Ltd HA630-AE-NNEA0** | 630.0 W | 600.8 W | 55.9 V | 46.5 V | 22.74% |
| **Hansol Technics Co Ltd HA635-AE-NNEA0** | 635.0 W | 605.7 W | 56.1 V | 46.7 V | 22.92% |
| **Hansol Technics Co Ltd HA640-AE-NNEA0** | 640.0 W | 610.6 W | 56.3 V | 46.9 V | 23.1% |
| **Hansol Technics Co Ltd HA645-AE-NNEA0** | 645.0 W | 615.5 W | 56.5 V | 47.1 V | 23.29% |

## How Many Hansol Technics Co Ltd HA635-AE-NNEA0 Modules Fit in a Cold-Weather String?

Maximum series module counts for Hansol Technics Co Ltd HA635-AE-NNEA0 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=56.1V and beta_Voc=-0.227%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 61.83 V | 9 panels | 556.5 V | 16 panels |
| **-10 C (14 F)** | 60.56 V | 9 panels | 545.0 V | 16 panels |
| **0 C (32 F)** | 59.28 V | 10 panels | 592.8 V | 16 panels |
| **25 C (77 F STC)** | 56.1 V | 10 panels | 561.0 V | 17 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA635-AE-NNEA0?

Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W), including New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10**](https://epri-peac.com/solar-equipment/modules/new-east-solar-energy-cambodia-coltd/new-east-solar-energy-cambodia-coltd-nese635-78thb-m10/) New East Solar Energy (Cambodia) CoLtd | 635.0 W | Tie (0 W) | 56.1 V | 22.92% | 95.4% |
| [**Hanersun Energy Co Ltd HN18N-78HT635W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-78ht635w/) Hanersun Energy Co Ltd | 635.0 W | Tie (0 W) | 56.2 V | 23.26% | 95.0% |
| [**ELITE Solar ET-N778TBH635GB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n778tbh635gb/) ELITE Solar | 635.0 W | Tie (0 W) | 56.69 V | 22.68% | 95.0% |
| [**ELITE Solar ET-N778TBH635GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-n778tbh635gl/) ELITE Solar | 635.0 W | Tie (0 W) | 56.69 V | 22.68% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA635-AE-NNEA0?

Evaluate Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W STC, 56.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA635-AE-NNEA0 reaches 61.83 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA635-AE-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hansol Technics Co Ltd HA635-AE-NNEA0 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 605.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA635-AE-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA635-AE-NNEA0?

Multiplying Hansol Technics Co Ltd HA635-AE-NNEA0's 14.36 A short-circuit current by 1.56 equals 22.4 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Hansol Technics Co Ltd HA635-AE-NNEA0 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 60.56 V cold Voc at 14 F and handles 14.36 A Isc; string inverters cap Hansol Technics Co Ltd HA635-AE-NNEA0 at 9 panels on 600 V.

### Is Hansol Technics Co Ltd HA635-AE-NNEA0 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA635-AE-NNEA0 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare Hansol Technics Co Ltd equipment, New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 specs, utility payback rates, and NEC string calculators alongside Hansol Technics Co Ltd HA635-AE-NNEA0.

[All Hansol Technics Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hansol Technics Co Ltd

- [All Hansol Technics Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/)
- [Hansol Technics Co Ltd HA650-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/)
- [Hansol Technics Co Ltd HA630AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha630ae-ngea0/)
- [Hansol Technics Co Ltd HA615-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615-ae-nnea0/)
- [Hansol Technics Co Ltd HA615AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615ae-ngea0/)
- [Hansol Technics Co Ltd HA605ZB-GGFA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha605zb-ggfa0/)
