title: "Hansol Technics Co Ltd Specs (600.0W, 52.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha600-ad-nnea0/
description: "CEC datasheet for Hansol Technics Co Ltd HA600-AD-NNEA0: 600.0W STC, 52.3V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hansol Technics Co Ltd HA600-AD-NNEA0 — CEC Solar Module Specifications

Manufacturer: [**Hansol Technics Co Ltd**](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hansol Technics Co Ltd HA600-AD-NNEA0 is a 600.0 W STC (559.9 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.44% efficiency, 52.3 V Voc at 25 C, and 58.03 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 600.0 W

- **PTC Wattage** : 559.9 W

- **Voc @ 25C** : 52.3 V

- **Efficiency** : 23.44%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hansol Technics Co Ltd HA600-AD-NNEA0 Compare Against Peer CEC Listings?

Engineering position of Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC) vs. HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI across 5,889 CEC Mono-c-Si solar modules.

Ranking #1,320 across 21,677 CEC solar panels (top 6.7%; higher than 93.3% of peers), Hansol Technics Co Ltd HA600-AD-NNEA0 operates as a large-format commercial and ground-mount module sitting 190.0 W above the 410.0 W Mono-c-Si median. Higher 52.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), 14 panels occupy 386 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Hansol Technics Co Ltd HA600-AD-NNEA0 Fall Across Listed CEC Models?

Plots Hansol Technics Co Ltd HA600-AD-NNEA0 at 600.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Hansol Technics Co Ltd HA600-AD-NNEA0?

Benchmarks Hansol Technics Co Ltd HA600-AD-NNEA0 on STC wattage, thermal PTC/STC retention, and 23.44 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA600-AD-NNEA0?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HA600-AD-NNEA0 by Hansol Technics Co Ltd.

Rank #1,320 / 21,677

### Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #589

### 23.44% Aperture Efficiency

Power density 234.4 W/m2 (3.53 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.03 V at -10 C (580.3 V string) and 59.67 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,400 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,839 W PTC; NEC 690.8 OCPD floor is 22.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.3 * (1 + (-0.313/100) * (-10 - 25)) = 58.03 V | OCPD = 1.56 * 14.59 = 22.76 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA600-AD-NNEA0: Voc=52.3 V, beta_Voc=-0.313%/C, Isc=14.59 A, STC=600.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (580.3 V); 14 panels for 8 kW (386 sq ft).

## What Are the Published CEC Specifications for Hansol Technics Co Ltd HA600-AD-NNEA0?

Laboratory test ratings recorded for Hansol Technics Co Ltd HA600-AD-NNEA0 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA600-AD-NNEA0.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 559.9 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.6 V / 13.77 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.313 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.44% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hansol Technics Co Ltd HA600-AD-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HA600-AD-NNEA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.0 kW | 276 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 14 | 8.4 kW | 386 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 17 | 10.2 kW | 468 sq ft | $2,553 | $4,317 |

## How Many Hansol Technics Co Ltd HA600-AD-NNEA0 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hansol Technics Co Ltd HA600-AD-NNEA0 (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=52.3V and beta_Voc=-0.313%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.67 V | 10 panels | 596.7 V | 16 panels |
| **-10 C (14 F)** | 58.03 V | 10 panels | 580.3 V | 17 panels |
| **0 C (32 F)** | 56.39 V | 10 panels | 563.9 V | 17 panels |
| **25 C (77 F STC)** | 52.3 V | 11 panels | 575.3 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA600-AD-NNEA0?

Closest cross-brand CEC competitors to Hansol Technics Co Ltd HA600-AD-NNEA0 matched near 600.0 W STC and 52.3 V Voc, led by HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI**](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-hin-t600ni/) HD HYUNDAI ENERGY SOLUTIONS CO LTD | 600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |
| [**Mission Solar Energy LLC MSN10-600HN4G**](https://epri-peac.com/solar-equipment/modules/mission-solar-energy-llc/mission-solar-energy-llc-msn10-600hn4g/) Mission Solar Energy LLC | 600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |
| [**New East Solar Energy (Cambodia) CoLtd NESE600-72THB-M10**](https://epri-peac.com/solar-equipment/modules/new-east-solar-energy-cambodia-coltd/new-east-solar-energy-cambodia-coltd-nese600-72thb-m10/) New East Solar Energy (Cambodia) CoLtd | 600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |
| [**Chint New Energy Technology Co Ltd CHSM72N-HC-600**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72n-hc-600/) Chint New Energy Technology Co Ltd | 600.0 W | Tie (0 W) | 51.75 V | 23.26% | 94.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA600-AD-NNEA0?

Evaluate Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC, 52.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA600-AD-NNEA0 reaches 59.67 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA600-AD-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hansol Technics Co Ltd HA600-AD-NNEA0 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 559.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA600-AD-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Hansol Technics Co Ltd HA600-AD-NNEA0 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HA600-AD-NNEA0 cold Voc rises from 52.3 V to 58.03 V (beta_Voc -0.313%/C), capping a 600 V string at 10 panels (580.3 V).

### How much roof area does an 8 kW array of Hansol Technics Co Ltd HA600-AD-NNEA0 need?

An 8 kW DC system uses 14 Hansol Technics Co Ltd HA600-AD-NNEA0 modules (8,400 W STC / 7,839 W PTC), covering roughly 386 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

### How does Hansol Technics Co Ltd HA600-AD-NNEA0 compare against HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI?

Hansol Technics Co Ltd HA600-AD-NNEA0 outputs 600.0 W STC (52.3 V Voc, rank #1,320 of 21,677), while HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI delivers 600.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Hansol Technics Co Ltd equipment, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI specs, utility payback rates, and NEC string calculators alongside Hansol Technics Co Ltd HA600-AD-NNEA0.

[All Hansol Technics Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hansol Technics Co Ltd

- [All Hansol Technics Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hansol-technics-co-ltd/)
- [Hansol Technics Co Ltd HA650-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha650-ae-nnea0/)
- [Hansol Technics Co Ltd HA635-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha635-ae-nnea0/)
- [Hansol Technics Co Ltd HA630AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha630ae-ngea0/)
- [Hansol Technics Co Ltd HA615-AE-NNEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615-ae-nnea0/)
- [Hansol Technics Co Ltd HA615AE-NGEA0](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha615ae-ngea0/)