title: "Hanersun Energy Co Ltd Specs (440.0W, 35.33V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21rn-48ht440w/
description: "CEC datasheet for Hanersun Energy Co Ltd HN21RN-48HT440W: 440.0W STC, 35.33V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hanersun Energy Co Ltd HN21RN-48HT440W — CEC Solar Module Specifications

Manufacturer: [**Hanersun Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hanersun Energy Co Ltd HN21RN-48HT440W is a 440.0 W STC (418.2 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.68% efficiency, 35.33 V Voc at 25 C, and 38.72 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 418.2 W

- **Voc @ 25C** : 35.33 V

- **Efficiency** : 22.68%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hanersun Energy Co Ltd HN21RN-48HT440W Compare Against Peer CEC Listings?

How Hanersun Energy Co Ltd Hanersun Energy Co Ltd HN21RN-48HT440W handles rooftop heat (418.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hanersun Energy Co Ltd HN21RN-48HT440W exhibits 15.88 A short-circuit current, requiring a 24.77 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #6,418 of 21,677 (30.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 36.9 m2 for an 8 kW system (23 panels for 10 kW). Lower 35.33 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

## Where Does Hanersun Energy Co Ltd HN21RN-48HT440W Fall Across Listed CEC Models?

Where Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Hanersun Energy Co Ltd HN21RN-48HT440W?

Percentile placement of Hanersun Energy Co Ltd HN21RN-48HT440W across power density (226.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21RN-48HT440W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hanersun Energy Co Ltd HN21RN-48HT440W specifications.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,656

### 22.68% Aperture Efficiency

Power density 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.72 V at -10 C (580.8 V string) and 39.69 V at -20 C (15 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 36.9 m2 (397 sq ft) producing 7,946 W PTC; NEC 690.8 OCPD floor is 24.77 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.33 * (1 + (-0.274/100) * (-10 - 25)) = 38.72 V | OCPD = 1.56 * 15.88 = 24.77 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21RN-48HT440W: Voc=35.33 V, beta_Voc=-0.274%/C, Isc=15.88 A, STC=440.0 W, Area=1.94 m2.

**Result:** 15 panels max on 600 V (580.8 V); 19 panels for 8 kW (397 sq ft).

## What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21RN-48HT440W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanersun Energy Co Ltd HN21RN-48HT440W.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN21RN-48HT440W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 418.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 35.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 15.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.46 V / 14.94 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.274 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.68% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hanersun Energy Co Ltd HN21RN-48HT440W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 292 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 397 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 480 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

All closely matched Hanersun Energy Co Ltd wattages and cosmetic trims sharing the Hanersun Energy Co Ltd HN21RN-48HT440W architecture.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN21RN-48HT440W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hanersun Energy Co Ltd HN21RN-48HT430W** | 430.0 W | 408.5 W | 34.93 V | 29.14 V | 22.16% |
| **Hanersun Energy Co Ltd HN21RN-48HT435W** | 435.0 W | 413.3 W | 35.13 V | 29.3 V | 22.42% |
| **Hanersun Energy Co Ltd HN21RN-48HT440W** | 440.0 W | 418.2 W | 35.33 V | 29.46 V | 22.68% |
| **Hanersun Energy Co Ltd HN21RN-48HT445W** | 445.0 W | 423.0 W | 35.53 V | 29.62 V | 22.94% |

## How Many Hanersun Energy Co Ltd HN21RN-48HT440W Modules Fit in a Cold-Weather String?

Maximum series module counts for Hanersun Energy Co Ltd HN21RN-48HT440W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=35.33V and beta_Voc=-0.274%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 39.69 V | 15 panels | 595.3 V | 25 panels |
| **-10 C (14 F)** | 38.72 V | 15 panels | 580.8 V | 25 panels |
| **0 C (32 F)** | 37.75 V | 15 panels | 566.2 V | 26 panels |
| **25 C (77 F STC)** | 35.33 V | 16 panels | 565.3 V | 28 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21RN-48HT440W?

Alternative CEC solar modules from competing brands near Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W), including ELITE Solar ET-NR48TBH440GB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ELITE Solar ET-NR48TBH440GB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-nr48tbh440gb/) ELITE Solar | 440.0 W | Tie (0 W) | 35.29 V | 22.0% | 95.0% |
| [**ELITE Solar ET-NR48TBH440GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-nr48tbh440gl/) ELITE Solar | 440.0 W | Tie (0 W) | 35.29 V | 22.0% | 95.0% |
| [**CSI Solar Co Ltd CS62-48TM-440H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs62-48tm-440h/) CSI Solar Co Ltd | 440.0 W | Tie (0 W) | 35.4 V | 22.8% | 94.9% |
| [**CSI Solar Co Ltd CS61-54TM-440H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-54tm-440h/) CSI Solar Co Ltd | 440.0 W | Tie (0 W) | 38.5 V | 22.22% | 94.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21RN-48HT440W?

Evaluate Hanersun Energy Co Ltd HN21RN-48HT440W (440.0 W STC, 35.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21RN-48HT440W reaches 39.69 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21RN-48HT440W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hanersun Energy Co Ltd HN21RN-48HT440W 8 kW Residential Fit

Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare ELITE Solar ET-NR48TBH440GB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN21RN-48HT440W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Hanersun Energy Co Ltd HN21RN-48HT440W PTC wattage (418.2 W) lower than STC (440.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 418.2 W PTC (95.0% retention) across Hanersun Energy Co Ltd HN21RN-48HT440W's 1.94 m2 aperture.

### Who should skip Hanersun Energy Co Ltd HN21RN-48HT440W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Hanersun Energy Co Ltd HN21RN-48HT440W panels (397 sq ft) leave unusable roof gaps vs. ELITE Solar ET-NR48TBH440GB.

### What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN21RN-48HT440W?

On 1,000 V commercial inverters at -10 C (38.72 V cold Voc), Hanersun Energy Co Ltd HN21RN-48HT440W fits up to 25 panels per series string.

## Related Pages

Compare Hanersun Energy Co Ltd equipment, ELITE Solar ET-NR48TBH440GB specs, utility payback rates, and NEC string calculators alongside Hanersun Energy Co Ltd HN21RN-48HT440W.

[All Hanersun Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hanersun Energy Co Ltd

- [All Hanersun Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/)
- [Hanersun Energy Co Ltd HN21N-66HT705W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht705w/)
- [Hanersun Energy Co Ltd HN21N-66HT685W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht685w/)
- [Hanersun Energy Co Ltd HN21N-66HT670W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht670w/)
- [Hanersun Energy Co Ltd HN21-66HT660W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21-66ht660w/)
- [Hanersun Energy Co Ltd HN21-66HT640W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21-66ht640w/)