title: "Hanersun Energy Co Ltd Specs (435.0W, 38.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-54ht435w/
description: "CEC datasheet for Hanersun Energy Co Ltd HN18N-54HT435W: 435.0W STC, 38.5V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hanersun Energy Co Ltd HN18N-54HT435W — CEC Solar Module Specifications

Manufacturer: [**Hanersun Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hanersun Energy Co Ltd HN18N-54HT435W is a 435.0 W STC (412.9 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.89% efficiency, 38.5 V Voc at 25 C, and 41.65 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 412.9 W

- **Voc @ 25C** : 38.5 V

- **Efficiency** : 22.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hanersun Energy Co Ltd HN18N-54HT435W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanersun Energy Co Ltd HN18N-54HT435W (Mono-c-Si) residential solar systems.

Homeowners evaluating Hanersun Energy Co Ltd HN18N-54HT435W need 14 panels for 6 kW or 19 panels (389 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.234%/C) pushes open-circuit voltage to 41.65 V at 14 F and 42.55 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Hanersun Energy Co Ltd HN18N-54HT435W Fall Across Listed CEC Models?

Comparison of Hanersun Energy Co Ltd HN18N-54HT435W (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Hanersun Energy Co Ltd HN18N-54HT435W?

Relative ranking of Hanersun Energy Co Ltd HN18N-54HT435W across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18N-54HT435W?

Summary of Hanersun Energy Co Ltd HN18N-54HT435W output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,307

### 22.89% Aperture Efficiency

Power density 228.9 W/m2 (2.98 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.65 V at -10 C (583.1 V string) and 42.55 V at -20 C (14 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,845 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.5 * (1 + (-0.234/100) * (-10 - 25)) = 41.65 V | OCPD = 1.56 * 14.19 = 22.14 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18N-54HT435W: Voc=38.5 V, beta_Voc=-0.234%/C, Isc=14.19 A, STC=435.0 W, Area=1.9 m2.

**Result:** 14 panels max on 600 V (583.1 V); 19 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18N-54HT435W?

Complete CEC test sheet for Hanersun Energy Co Ltd HN18N-54HT435W including Isc (14.19 A), Voc (38.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN18N-54HT435W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 412.9 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.5 V / 13.39 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.234 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.89% (1.9 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Hanersun Energy Co Ltd HN18N-54HT435W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanersun Energy Co Ltd HN18N-54HT435W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 286 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 389 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 470 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

Related Hanersun Energy Co Ltd power steps and black/silver trims consolidated into this Hanersun Energy Co Ltd HN18N-54HT435W series guide.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN18N-54HT435W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hanersun Energy Co Ltd HN18N-54HT425W** | 425.0 W | 403.2 W | 38.1 V | 32.1 V | 22.37% |
| **Hanersun Energy Co Ltd HN18N-54HT430W** | 430.0 W | 408.1 W | 38.3 V | 32.3 V | 22.63% |
| **Hanersun Energy Co Ltd HN18N-54HT435W** | 435.0 W | 412.9 W | 38.5 V | 32.5 V | 22.89% |
| **Hanersun Energy Co Ltd HN18N-54HT440W** | 440.0 W | 417.8 W | 38.7 V | 32.7 V | 23.16% |
| **Hanersun Energy Co Ltd HN18N-54HT445W** | 445.0 W | 422.6 W | 38.9 V | 32.9 V | 23.42% |

## How Many Hanersun Energy Co Ltd HN18N-54HT435W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hanersun Energy Co Ltd HN18N-54HT435W (38.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.5V and beta_Voc=-0.234%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.55 V | 14 panels | 595.7 V | 23 panels |
| **-10 C (14 F)** | 41.65 V | 14 panels | 583.1 V | 24 panels |
| **0 C (32 F)** | 40.75 V | 14 panels | 570.5 V | 24 panels |
| **25 C (77 F STC)** | 38.5 V | 15 panels | 577.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18N-54HT435W?

Four comparable CEC modules such as AXITEC AC-435TGB/108BB (435.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-435TGB/108BB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435tgb-108bb/) AXITEC | 435.0 W | Tie (0 W) | 38.43 V | 22.89% | 95.0% |
| [**Auxin Solar AXN10M435B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m435b/) Auxin Solar | 435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.2% |
| [**Auxin Solar AXN10M435W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m435w/) Auxin Solar | 435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.3% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-n-435/) Elin Energy (Sirius PV) | 435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18N-54HT435W?

Evaluate Hanersun Energy Co Ltd HN18N-54HT435W (435.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18N-54HT435W reaches 42.55 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 389 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18N-54HT435W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hanersun Energy Co Ltd HN18N-54HT435W 8 kW Residential Fit

Needs 19 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-435TGB/108BB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN18N-54HT435W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Hanersun Energy Co Ltd HN18N-54HT435W PTC wattage (412.9 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.9 W PTC (94.9% retention) across Hanersun Energy Co Ltd HN18N-54HT435W's 1.9 m2 aperture.

### Who should skip Hanersun Energy Co Ltd HN18N-54HT435W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Hanersun Energy Co Ltd HN18N-54HT435W panels (389 sq ft) leave unusable roof gaps vs. AXITEC AC-435TGB/108BB.

### What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN18N-54HT435W?

On 1,000 V commercial inverters at -10 C (41.65 V cold Voc), Hanersun Energy Co Ltd HN18N-54HT435W fits up to 24 panels per series string.

## Related Pages

Compare Hanersun Energy Co Ltd equipment, AXITEC AC-435TGB/108BB specs, utility payback rates, and NEC string calculators alongside Hanersun Energy Co Ltd HN18N-54HT435W.

[All Hanersun Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hanersun Energy Co Ltd

- [All Hanersun Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/)
- [Hanersun Energy Co Ltd HN21N-66HT705W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht705w/)
- [Hanersun Energy Co Ltd HN21N-66HT685W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht685w/)
- [Hanersun Energy Co Ltd HN21N-66HT670W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht670w/)
- [Hanersun Energy Co Ltd HN21-66HT660W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21-66ht660w/)
- [Hanersun Energy Co Ltd HN21-66HT640W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21-66ht640w/)