title: "Hanersun Energy Co Ltd Specs (535.0W, 49.45V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18-72ht535w/
description: "CEC datasheet for Hanersun Energy Co Ltd HN18-72HT535W: 535.0W STC, 49.45V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Hanersun Energy Co Ltd HN18-72HT535W — CEC Solar Module Specifications

Manufacturer: [**Hanersun Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

Hanersun Energy Co Ltd HN18-72HT535W is a 535.0 W STC (505.0 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 21.23% efficiency, 49.45 V Voc at 25 C, and 53.83 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 535.0 W

- **PTC Wattage** : 505.0 W

- **Voc @ 25C** : 49.45 V

- **Efficiency** : 21.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Hanersun Energy Co Ltd HN18-72HT535W Compare Against Peer CEC Listings?

How Hanersun Energy Co Ltd Hanersun Energy Co Ltd HN18-72HT535W handles rooftop heat (505.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hanersun Energy Co Ltd HN18-72HT535W exhibits 13.79 A short-circuit current, requiring a 21.51 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,537 of 21,677 (125.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.8 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.45 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does Hanersun Energy Co Ltd HN18-72HT535W Fall Across Listed CEC Models?

Where Hanersun Energy Co Ltd HN18-72HT535W (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Hanersun Energy Co Ltd HN18-72HT535W?

Percentile placement of Hanersun Energy Co Ltd HN18-72HT535W across power density (212.3 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18-72HT535W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hanersun Energy Co Ltd HN18-72HT535W specifications.

Rank #3,537 / 21,677

### Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,486

### 21.23% Aperture Efficiency

Power density 212.3 W/m2 (1.32 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.83 V at -10 C (592.1 V string) and 55.08 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,025 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,575 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.45 * (1 + (-0.253/100) * (-10 - 25)) = 53.83 V | OCPD = 1.56 * 13.79 = 21.51 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18-72HT535W: Voc=49.45 V, beta_Voc=-0.253%/C, Isc=13.79 A, STC=535.0 W, Area=2.52 m2.

**Result:** 11 panels max on 600 V (592.1 V); 15 panels for 8 kW (407 sq ft).

## What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18-72HT535W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanersun Energy Co Ltd HN18-72HT535W.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN18-72HT535W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 505.0 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.47 V / 12.9 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.253 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.23% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Hanersun Energy Co Ltd HN18-72HT535W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanersun Energy Co Ltd HN18-72HT535W (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.42 kW | 326 sq ft | $1,607 | $2,717 |
| **8 kW Class** | 15 | 8.03 kW | 407 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 19 | 10.16 kW | 515 sq ft | $2,543 | $4,300 |

## Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

All closely matched Hanersun Energy Co Ltd wattages and cosmetic trims sharing the Hanersun Energy Co Ltd HN18-72HT535W architecture.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN18-72HT535W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Hanersun Energy Co Ltd HN18-72HT525W** | 525.0 W | 495.4 W | 49.15 V | 41.15 V | 20.83% |
| **Hanersun Energy Co Ltd HN18-72HT530W** | 530.0 W | 500.2 W | 49.3 V | 41.31 V | 21.03% |
| **Hanersun Energy Co Ltd HN18-72HT535W** | 535.0 W | 505.0 W | 49.45 V | 41.47 V | 21.23% |
| **Hanersun Energy Co Ltd HN18-72HT540W** | 540.0 W | 509.9 W | 49.6 V | 41.64 V | 21.43% |
| **Hanersun Energy Co Ltd HN18-72HT545W** | 545.0 W | 514.7 W | 49.75 V | 41.8 V | 21.63% |

## How Many Hanersun Energy Co Ltd HN18-72HT535W Modules Fit in a Cold-Weather String?

Maximum series module counts for Hanersun Energy Co Ltd HN18-72HT535W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.45V and beta_Voc=-0.253%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.08 V | 10 panels | 550.8 V | 18 panels |
| **-10 C (14 F)** | 53.83 V | 11 panels | 592.1 V | 18 panels |
| **0 C (32 F)** | 52.58 V | 11 panels | 578.4 V | 19 panels |
| **25 C (77 F STC)** | 49.45 V | 12 panels | 593.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18-72HT535W?

Alternative CEC solar modules from competing brands near Hanersun Energy Co Ltd HN18-72HT535W (535.0 W), including Bila Solar Inc AA535US-6x24GG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bila Solar Inc AA535US-6x24GG**](https://epri-peac.com/solar-equipment/modules/bila-solar-inc/bila-solar-inc-aa535us-6x24gg/) Bila Solar Inc | 535.0 W | Tie (0 W) | 49.45 V | 21.31% | 92.8% |
| [**ES Foundry Corp ES-DP8-H72-535**](https://epri-peac.com/solar-equipment/modules/es-foundry-corp/es-foundry-corp-es-dp8-h72-535/) ES Foundry Corp | 535.0 W | Tie (0 W) | 49.45 V | 20.9% | 93.8% |
| [**Hyperion Solar HY-DH144P8-535**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-535/) Hyperion Solar | 535.0 W | Tie (0 W) | 49.45 V | 20.74% | 93.0% |
| [**Hyperion Solar HY-DH144P8-535-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-535-b/) Hyperion Solar | 535.0 W | Tie (0 W) | 49.45 V | 20.74% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18-72HT535W?

Evaluate Hanersun Energy Co Ltd HN18-72HT535W (535.0 W STC, 49.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18-72HT535W reaches 55.08 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18-72HT535W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Hanersun Energy Co Ltd HN18-72HT535W 8 kW Residential Fit

Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bila Solar Inc AA535US-6x24GG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 505.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN18-72HT535W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Hanersun Energy Co Ltd HN18-72HT535W PTC wattage (505.0 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 505.0 W PTC (94.4% retention) across Hanersun Energy Co Ltd HN18-72HT535W's 2.52 m2 aperture.

### Who should skip Hanersun Energy Co Ltd HN18-72HT535W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Hanersun Energy Co Ltd HN18-72HT535W panels (407 sq ft) leave unusable roof gaps vs. Bila Solar Inc AA535US-6x24GG.

### What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN18-72HT535W?

On 1,000 V commercial inverters at -10 C (53.83 V cold Voc), Hanersun Energy Co Ltd HN18-72HT535W fits up to 18 panels per series string.

## Related Pages

Compare Hanersun Energy Co Ltd equipment, Bila Solar Inc AA535US-6x24GG specs, utility payback rates, and NEC string calculators alongside Hanersun Energy Co Ltd HN18-72HT535W.

[All Hanersun Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Hanersun Energy Co Ltd

- [All Hanersun Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/hanersun-energy-co-ltd/)
- [Hanersun Energy Co Ltd HN21N-66HT705W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht705w/)
- [Hanersun Energy Co Ltd HN21N-66HT685W](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21n-66ht685w/)