title: "HALEE Inc HST-61-E-FP Specs (61.0W, 9.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/halee-inc/halee-inc-hst-61-e-fp/
description: "CEC datasheet for HALEE Inc HST-61-E-FP: 61.0W STC, 9.5V Voc, 132-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# HALEE Inc HST-61-E-FP — CEC Solar Module Specifications

Manufacturer: [**HALEE Inc**](https://epri-peac.com/solar-equipment/brands/halee-inc/) Registry: **CEC Verified Engineering Specification**

HALEE Inc HST-61-E-FP is a 61.0 W STC (52.2 W PTC) Mono-c-Si solar module ranking #21,651 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 14.88% efficiency, 9.5 V Voc at 25 C, and 10.37 V cold Voc at -10 C (57 panels max per 600 V string).

- **STC Wattage** : 61.0 W

- **PTC Wattage** : 52.2 W

- **Voc @ 25C** : 9.5 V

- **Efficiency** : 14.88%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HALEE Inc HST-61-E-FP Compare Against Peer CEC Listings?

Solar engineering breakdown for HALEE Inc HST-61-E-FP: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Measured at 61.0 W STC and 52.2 W PTC, HALEE Inc HST-61-E-FP sits -324.0 W vs all-CEC median (below all-CEC median; higher than 0.1% of peers) among 21,677 listed modules. Power density reaches 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). Lower 9.5 V string voltage fits 57 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 96 panels in series. Alternative peer CertainTeed Apollo II - 67 rates 67.0 W.

## Where Does HALEE Inc HST-61-E-FP Fall Across Listed CEC Models?

Distribution marker showing HALEE Inc HST-61-E-FP (61.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define HALEE Inc HST-61-E-FP?

Dataset percentiles tracking HALEE Inc HST-61-E-FP power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Do the Dataset Ranks Show for HALEE Inc HST-61-E-FP?

Benchmark highlights for HALEE Inc HST-61-E-FP covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #21,651 / 21,677

### 61.0 W STC · Higher Than 0.1%

61.0 W STC (-324.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,900

### 14.88% Aperture Efficiency

Power density 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). PTC/STC ratio: 85.6% (rank #21,656).

NEC 690.7 Limit

### 57 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.37 V at -10 C (591.1 V string) and 10.62 V at -20 C (56 max).

 8 kW Reference Array

### 132 Panels = 8,052 W STC

Occupies 54.1 m2 (583 sq ft) producing 6,890 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.5 * (1 + (-0.263/100) * (-10 - 25)) = 10.37 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for HALEE Inc HST-61-E-FP: Voc=9.5 V, beta_Voc=-0.263%/C, Isc=8.6 A, STC=61.0 W, Area=0.41 m2.

**Result:** 57 panels max on 600 V (591.1 V); 132 panels for 8 kW (583 sq ft).

## What Are the Published CEC Specifications for HALEE Inc HST-61-E-FP?

Official CEC datasheet figures for HALEE Inc HST-61-E-FP (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for HALEE Inc HST-61-E-FP.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 61.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 52.2 W (85.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 9.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 7.6 V / 8.1 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.263 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.88% (0.41 m2) | Array roof footprint density |
| **Cell Count & Technology** | 14 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HALEE Inc HST-61-E-FP Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HALEE Inc HST-61-E-FP modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 99 | 6.04 kW | 437 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 132 | 8.05 kW | 583 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 164 | 10.0 kW | 724 sq ft | $2,503 | $4,232 |

## How Many HALEE Inc HST-61-E-FP Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HALEE Inc HST-61-E-FP (10.37 V at 14 F).

Computed from Voc=9.5V and beta_Voc=-0.263%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 10.62 V | 56 panels | 594.7 V | 94 panels |
| **-10 C (14 F)** | 10.37 V | 57 panels | 591.1 V | 96 panels |
| **0 C (32 F)** | 10.12 V | 59 panels | 597.1 V | 98 panels |
| **25 C (77 F STC)** | 9.5 V | 63 panels | 598.5 V | 105 panels |

## Which Cross-Brand Solar Modules Compare Closest to HALEE Inc HST-61-E-FP?

Competing CEC solar panels closest to HALEE Inc HST-61-E-FP in nameplate wattage and Voc, starting with CertainTeed Apollo II - 67.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed Apollo II - 67**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-ii-67/) CertainTeed | 67.0 W | +6.0 W | 9.35 V | 15.95% | 90.9% |
| [**CertainTeed Apollo Tile II - 67**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-apollo-tile-ii-67/) CertainTeed | 67.0 W | +6.0 W | 9.35 V | 15.95% | 91.2% |
| [**CertainTeed Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-solstice-shingle-68w-01/) CertainTeed | 68.0 W | +7.0 W | 9.37 V | 12.83% | 89.4% |
| [**Merlin Solar Technologies Inc Solstice Shingle 68W-01**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-solstice-shingle-68w-01/) Merlin Solar Technologies Inc | 68.0 W | +7.0 W | 9.37 V | 12.83% | 89.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HALEE Inc HST-61-E-FP?

Evaluate HALEE Inc HST-61-E-FP (61.0 W STC, 9.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HALEE Inc HST-61-E-FP reaches 10.62 V per panel—exceeding 56 panels in series voids 600 V inverter warranties.
- Footprint constraint: 132 panels for an 8 kW build require 583 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 132 panels (583 sq ft).
- 2026 tax credit baseline: cash residential installs of HALEE Inc HST-61-E-FP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HALEE Inc HST-61-E-FP 8 kW Residential Fit

Needs 132 modules (583 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 57 panels (-10 C) or 56 panels (-20 C), or compare CertainTeed Apollo II - 67.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 52.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HALEE Inc HST-61-E-FP by HALEE Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HALEE Inc HST-61-E-FP panels fit on a 600 V winter solar string?

At -10 C (14 F), HALEE Inc HST-61-E-FP cold Voc rises from 9.5 V to 10.37 V (beta_Voc -0.263%/C), capping a 600 V string at 57 panels (591.1 V).

### How much roof area does an 8 kW array of HALEE Inc HST-61-E-FP need?

An 8 kW DC system uses 132 HALEE Inc HST-61-E-FP modules (8,052 W STC / 6,890 W PTC), covering roughly 583 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

### How does HALEE Inc HST-61-E-FP compare against CertainTeed Apollo II - 67?

HALEE Inc HST-61-E-FP outputs 61.0 W STC (9.5 V Voc, rank #21,651 of 21,677), while CertainTeed Apollo II - 67 delivers 67.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HALEE Inc equipment, CertainTeed Apollo II - 67 specs, utility payback rates, and NEC string calculators alongside HALEE Inc HST-61-E-FP.

[All HALEE Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/halee-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HALEE Inc

- [All HALEE Inc Specs](https://epri-peac.com/solar-equipment/brands/halee-inc/)