title: "Gintung Energy GTEC-265G6S6B Specs (265.0W, 40.88V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-265g6s6b/
description: "CEC datasheet for Gintung Energy GTEC-265G6S6B: 265.0W STC, 40.88V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy GTEC-265G6S6B — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy GTEC-265G6S6B is a 265.0 W STC (231.9 W PTC) Mono-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 14.94% efficiency, 40.88 V Voc at 25 C, and 45.79 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 265.0 W

- **PTC Wattage** : 231.9 W

- **Voc @ 25C** : 40.88 V

- **Efficiency** : 14.94%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy GTEC-265G6S6B Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy GTEC-265G6S6B handles rooftop heat (231.9 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Gintung Energy GTEC-265G6S6B exhibits 8.69 A short-circuit current, requiring a 13.56 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (145.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 55.0 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 40.88 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does Gintung Energy GTEC-265G6S6B Fall Across Listed CEC Models?

Where Gintung Energy GTEC-265G6S6B (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Gintung Energy GTEC-265G6S6B?

Percentile placement of Gintung Energy GTEC-265G6S6B across power density (149.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Gintung Energy GTEC-265G6S6B?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-265G6S6B specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #18,880 / 21,677

### 265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,852

### 14.94% Aperture Efficiency

Power density 149.5 W/m2 (4.97 percentage points below 19.91% CEC median). PTC/STC ratio: 87.5% (rank #21,548).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.79 V at -10 C (595.3 V string) and 47.19 V at -20 C (12 max).

 8 kW Reference Array

### 31 Panels = 8,215 W STC

Occupies 55.0 m2 (592 sq ft) producing 7,189 W PTC; NEC 690.8 OCPD floor is 13.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.88 * (1 + (-0.343/100) * (-10 - 25)) = 45.79 V | OCPD = 1.56 * 8.69 = 13.56 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-265G6S6B: Voc=40.88 V, beta_Voc=-0.343%/C, Isc=8.69 A, STC=265.0 W, Area=1.773 m2.

**Result:** 13 panels max on 600 V (595.3 V); 31 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for Gintung Energy GTEC-265G6S6B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-265G6S6B.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-265G6S6B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 231.9 W (87.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.88 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.52 V / 8.15 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.94% (1.773 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Gintung Energy GTEC-265G6S6B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-265G6S6B (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 31 | 8.21 kW | 592 sq ft | $2,055 | $3,475 |
| **10 kW Class** | 38 | 10.07 kW | 725 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-265G6S6B architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Gintung Energy GTEC-265G6S6B wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy GTEC-260G6S6B** | 260.0 W | 227.4 W | 40.73 V | 32.26 V | 14.66% |
| **Gintung Energy GTEC-265G6S6B** | 265.0 W | 231.9 W | 40.88 V | 32.52 V | 14.94% |
| **Gintung Energy GTEC-270G6S6B** | 270.0 W | 236.4 W | 40.97 V | 32.53 V | 15.23% |

## How Many Gintung Energy GTEC-265G6S6B Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy GTEC-265G6S6B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.88V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 47.19 V | 12 panels | 566.3 V | 21 panels |
| **-10 C (14 F)** | 45.79 V | 13 panels | 595.3 V | 21 panels |
| **0 C (32 F)** | 44.39 V | 13 panels | 577.1 V | 22 panels |
| **25 C (77 F STC)** | 40.88 V | 14 panels | 572.3 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-265G6S6B?

Alternative CEC solar modules from competing brands near Gintung Energy GTEC-265G6S6B (265.0 W), including Anhui Rinengzhongtian Semiconductor Development QJP265-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJP265-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp265-72/) Anhui Rinengzhongtian Semiconductor Development | 265.0 W | Tie (0 W) | 42.3 V | 13.66% | 89.1% |
| [**BYD Company Limited BYD 265P6C-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-265p6c-36/) BYD Company Limited | 265.0 W | Tie (0 W) | 43.11 V | 13.66% | 90.9% |
| [**Advance Power API-P265**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p265/) Advance Power | 265.0 W | Tie (0 W) | 43.27 V | 13.58% | 89.1% |
| [**Auxin Solar AXN6P610T265**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p610t265/) Auxin Solar | 265.0 W | Tie (0 W) | 43.27 V | 13.58% | 89.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-265G6S6B?

Evaluate Gintung Energy GTEC-265G6S6B (265.0 W STC, 40.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-265G6S6B reaches 47.19 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-265G6S6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy GTEC-265G6S6B 8 kW Residential Fit

Needs 31 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP265-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 231.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-265G6S6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Gintung Energy GTEC-265G6S6B PTC wattage (231.9 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 231.9 W PTC (87.5% retention) across Gintung Energy GTEC-265G6S6B's 1.773 m2 aperture.

### Who should skip Gintung Energy GTEC-265G6S6B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Gintung Energy GTEC-265G6S6B panels (592 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJP265-72.

### What is the 1,000 V commercial string limit for Gintung Energy GTEC-265G6S6B?

On 1,000 V commercial inverters at -10 C (45.79 V cold Voc), Gintung Energy GTEC-265G6S6B fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy GTEC-265G6S6B.

## Related Pages

Compare Gintung Energy equipment, Anhui Rinengzhongtian Semiconductor Development QJP265-72 specs, utility payback rates, and NEC string calculators alongside Gintung Energy GTEC-265G6S6B.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)