Gintung Energy GTEC-265G6M6B is a 265.0 W STC (232.9 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 14.94% efficiency, 41.35 V Voc at 25 C, and 46.31 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 265.0 W

- **PTC Wattage** : 232.9 W

- **Voc @ 25C** : 41.35 V

- **Efficiency** : 14.94%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy GTEC-265G6M6B Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy GTEC-265G6M6B: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Across 1,407 Multi-c-Si listings from Gintung Energy and peers, Gintung Energy GTEC-265G6M6B stands 13.8 W below the 278.8 W Multi-c-Si median and typical 87.9% PTC-to-STC thermal output (232.9 W real-world rating). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,524-$2,520/yr in baseline US bill offset. Mid-range 41.35 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

## Where Does Gintung Energy GTEC-265G6M6B Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy GTEC-265G6M6B (265.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Dataset Percentiles Define Gintung Energy GTEC-265G6M6B?

Dataset percentiles tracking Gintung Energy GTEC-265G6M6B power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Do the Dataset Ranks Show for Gintung Energy GTEC-265G6M6B?

Benchmark highlights for Gintung Energy GTEC-265G6M6B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #18,880 / 21,677

### 265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,852

### 14.94% Aperture Efficiency

Power density 149.5 W/m2 (4.97 percentage points below 19.91% CEC median). PTC/STC ratio: 87.9% (rank #21,435).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.31 V at -10 C (555.7 V string) and 47.73 V at -20 C (12 max).

 8 kW Reference Array

### 31 Panels = 8,215 W STC

Occupies 55.0 m2 (592 sq ft) producing 7,220 W PTC; NEC 690.8 OCPD floor is 13.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.35 * (1 + (-0.343/100) * (-10 - 25)) = 46.31 V | OCPD = 1.56 * 8.59 = 13.4 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-265G6M6B: Voc=41.35 V, beta_Voc=-0.343%/C, Isc=8.59 A, STC=265.0 W, Area=1.773 m2.

**Result:** 12 panels max on 600 V (555.7 V); 31 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for Gintung Energy GTEC-265G6M6B?

Official CEC datasheet figures for Gintung Energy GTEC-265G6M6B (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-265G6M6B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 232.9 W (87.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.35 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.64 V / 8.12 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.94% (1.773 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy GTEC-265G6M6B Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy GTEC-265G6M6B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 31 | 8.21 kW | 592 sq ft | $2,055 | $3,475 |
| **10 kW Class** | 38 | 10.07 kW | 725 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-265G6M6B mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Gintung Energy GTEC-265G6M6B wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy GTEC-260G6M6B** | 260.0 W | 228.4 W | 41.21 V | 32.34 V | 14.66% |
| **Gintung Energy GTEC-265G6M6B** | 265.0 W | 232.9 W | 41.35 V | 32.64 V | 14.94% |
| **Gintung Energy GTEC-270G6M6B** | 270.0 W | 237.5 W | 41.44 V | 32.73 V | 15.23% |

## How Many Gintung Energy GTEC-265G6M6B Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-265G6M6B (46.31 V at 14 F).

Computed from Voc=41.35V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 47.73 V | 12 panels | 572.8 V | 20 panels |
| **-10 C (14 F)** | 46.31 V | 12 panels | 555.7 V | 21 panels |
| **0 C (32 F)** | 44.9 V | 13 panels | 583.7 V | 22 panels |
| **25 C (77 F STC)** | 41.35 V | 14 panels | 578.9 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-265G6M6B?

Competing CEC solar panels closest to Gintung Energy GTEC-265G6M6B in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJP265-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJP265-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp265-72/) Anhui Rinengzhongtian Semiconductor Development | 265.0 W | Tie (0 W) | 42.3 V | 13.66% | 89.1% |
| [**BYD Company Limited BYD 265P6C-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-265p6c-36/) BYD Company Limited | 265.0 W | Tie (0 W) | 43.11 V | 13.66% | 90.9% |
| [**Advance Power API-P265**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p265/) Advance Power | 265.0 W | Tie (0 W) | 43.27 V | 13.58% | 89.1% |
| [**Auxin Solar AXN6P610T265**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p610t265/) Auxin Solar | 265.0 W | Tie (0 W) | 43.27 V | 13.58% | 89.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-265G6M6B?

Evaluate Gintung Energy GTEC-265G6M6B (265.0 W STC, 41.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-265G6M6B reaches 47.73 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-265G6M6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy GTEC-265G6M6B 8 kW Residential Fit

Needs 31 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP265-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-265G6M6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-265G6M6B?

Multiplying Gintung Energy GTEC-265G6M6B's 8.59 A short-circuit current by 1.56 equals 13.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Gintung Energy GTEC-265G6M6B pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.31 V cold Voc at 14 F and handles 8.59 A Isc; string inverters cap Gintung Energy GTEC-265G6M6B at 12 panels on 600 V.

### Is Gintung Energy GTEC-265G6M6B eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-265G6M6B rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

## Related Pages

Compare Gintung Energy equipment, Anhui Rinengzhongtian Semiconductor Development QJP265-72 specs, utility payback rates, and NEC string calculators alongside Gintung Energy GTEC-265G6M6B.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)