# Gintung Energy GTEC-210G6S68 — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy GTEC-210G6S68 is a 210.0 W STC (184.3 W PTC) Mono-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 16.1% efficiency, 30.14 V Voc at 25 C, and 33.76 V cold Voc at -10 C (17 panels max per 600 V string).

- **STC Wattage** : 210.0 W

- **PTC Wattage** : 184.3 W

- **Voc @ 25C** : 30.14 V

- **Efficiency** : 16.1%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy GTEC-210G6S68 Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy GTEC-210G6S68 handles rooftop heat (184.3 W PTC), 8 kW sizing, and cold winter string voltage.

Gintung Energy builds the Gintung Energy GTEC-210G6S68 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 161.0 W/m2 (3.81 percentage points below 19.91% CEC median). Compared against Centrosolar America DP48 200 (200.0 W), this model holds typical 87.8% PTC-to-STC thermal output (184.3 W real-world rating). Lower 30.14 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.12 A overcurrent floor served by a 15 A breaker.

## Where Does Gintung Energy GTEC-210G6S68 Fall Across Listed CEC Models?

Where Gintung Energy GTEC-210G6S68 (210.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Gintung Energy GTEC-210G6S68?

Percentile placement of Gintung Energy GTEC-210G6S68 across power density (161.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Gintung Energy GTEC-210G6S68?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-210G6S68 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #20,916 / 21,677

### 210.0 W STC · Higher Than 3.2%

210.0 W STC (-175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,982

### 16.1% Aperture Efficiency

Power density 161.0 W/m2 (3.81 percentage points below 19.91% CEC median). PTC/STC ratio: 87.8% (rank #21,465).

NEC 690.7 Limit

### 17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.76 V at -10 C (573.9 V string) and 34.79 V at -20 C (17 max).

 8 kW Reference Array

### 39 Panels = 8,190 W STC

Occupies 50.9 m2 (547 sq ft) producing 7,188 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 30.14 * (1 + (-0.343/100) * (-10 - 25)) = 33.76 V | OCPD = 1.56 * 9.05 = 14.12 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-210G6S68: Voc=30.14 V, beta_Voc=-0.343%/C, Isc=9.05 A, STC=210.0 W, Area=1.304 m2.

**Result:** 17 panels max on 600 V (573.9 V); 39 panels for 8 kW (547 sq ft).

## What Are the Published CEC Specifications for Gintung Energy GTEC-210G6S68?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-210G6S68.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-210G6S68.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 210.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 184.3 W (87.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 30.14 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 24.11 V / 8.71 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.1% (1.304 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Gintung Energy GTEC-210G6S68 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-210G6S68 (210.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 29 | 6.09 kW | 407 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 39 | 8.19 kW | 547 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 48 | 10.08 kW | 674 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-210G6S68 architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Gintung Energy GTEC-210G6S68 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy GTEC-200G6S68** | 200.0 W | 175.2 W | 29.93 V | 23.84 V | 15.33% |
| **Gintung Energy GTEC-205G6S68** | 205.0 W | 179.7 W | 30.04 V | 24.0 V | 15.71% |
| **Gintung Energy GTEC-210G6S68** | 210.0 W | 184.3 W | 30.14 V | 24.11 V | 16.1% |
| **Gintung Energy GTEC-215G6S68** | 215.0 W | 188.8 W | 30.26 V | 24.24 V | 16.48% |
| **Gintung Energy GTEC-220G6S68** | 220.0 W | 193.4 W | 30.34 V | 24.36 V | 16.86% |

## How Many Gintung Energy GTEC-210G6S68 Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy GTEC-210G6S68 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=30.14V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 34.79 V | 17 panels | 591.4 V | 28 panels |
| **-10 C (14 F)** | 33.76 V | 17 panels | 573.9 V | 29 panels |
| **0 C (32 F)** | 32.72 V | 18 panels | 589.0 V | 30 panels |
| **25 C (77 F STC)** | 30.14 V | 19 panels | 572.7 V | 33 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-210G6S68?

Alternative CEC solar modules from competing brands near Gintung Energy GTEC-210G6S68 (210.0 W), including Centrosolar America DP48 200.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DP48 200**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp48-200/) Centrosolar America | 200.0 W | -10.0 W | 30.12 V | 15.09% | 88.6% |
| [**Centrosolar America DP54 210**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp54-210/) Centrosolar America | 210.0 W | Tie (0 W) | 33.23 V | 14.16% | 88.4% |
| [**APOS Energy AS210**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as210/) APOS Energy | 210.0 W | Tie (0 W) | 33.5 V | 14.0% | 89.7% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-P205**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-p205/) Hanwha Qcells (Qidong) Co Ltd | 205.0 W | -5.0 W | 32.9 V | 13.72% | 88.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-210G6S68?

Evaluate Gintung Energy GTEC-210G6S68 (210.0 W STC, 30.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-210G6S68 reaches 34.79 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-210G6S68 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy GTEC-210G6S68 8 kW Residential Fit

Needs 39 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Centrosolar America DP48 200.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 184.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-210G6S68 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-210G6S68?

Multiplying Gintung Energy GTEC-210G6S68's 9.05 A short-circuit current by 1.56 equals 14.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Gintung Energy GTEC-210G6S68 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 33.76 V cold Voc at 14 F and handles 9.05 A Isc; string inverters cap Gintung Energy GTEC-210G6S68 at 17 panels on 600 V.

### Is Gintung Energy GTEC-210G6S68 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-210G6S68 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Gintung Energy equipment, Centrosolar America DP48 200 specs, utility payback rates, and NEC string calculators alongside Gintung Energy GTEC-210G6S68.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)