title: "Gintung Energy GTEC-195G6S68 Specs (195.0W, 29.82V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-195g6s68/
description: "CEC datasheet for Gintung Energy GTEC-195G6S68: 195.0W STC, 29.82V Voc, 42-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy GTEC-195G6S68 — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy GTEC-195G6S68 is a 195.0 W STC (175.0 W PTC) Mono-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 14.95% efficiency, 29.82 V Voc at 25 C, and 33.37 V cold Voc at -10 C (17 panels max per 600 V string).

- **STC Wattage** : 195.0 W

- **PTC Wattage** : 175.0 W

- **Voc @ 25C** : 29.82 V

- **Efficiency** : 14.95%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy GTEC-195G6S68 Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy GTEC-195G6S68 handles rooftop heat (175.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Gintung Energy GTEC-195G6S68 exhibits 8.63 A short-circuit current, requiring a 13.46 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,088 of 21,677 (215.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 54.8 m2 for an 8 kW system (52 panels for 10 kW). Lower 29.82 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters.

## Where Does Gintung Energy GTEC-195G6S68 Fall Across Listed CEC Models?

Where Gintung Energy GTEC-195G6S68 (195.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Gintung Energy GTEC-195G6S68?

Percentile placement of Gintung Energy GTEC-195G6S68 across power density (149.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Gintung Energy GTEC-195G6S68?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-195G6S68 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,088 / 21,677

### 195.0 W STC · Higher Than 2.5%

195.0 W STC (-190.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,805

### 14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

### 17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.37 V at -10 C (567.3 V string) and 34.38 V at -20 C (17 max).

 8 kW Reference Array

### 42 Panels = 8,190 W STC

Occupies 54.8 m2 (590 sq ft) producing 7,350 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.82 * (1 + (-0.34/100) * (-10 - 25)) = 33.37 V | OCPD = 1.56 * 8.63 = 13.46 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-195G6S68: Voc=29.82 V, beta_Voc=-0.34%/C, Isc=8.63 A, STC=195.0 W, Area=1.304 m2.

**Result:** 17 panels max on 600 V (567.3 V); 42 panels for 8 kW (590 sq ft).

## What Are the Published CEC Specifications for Gintung Energy GTEC-195G6S68?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-195G6S68.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-195G6S68.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 195.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 175.0 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 29.82 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 23.67 V / 8.24 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.95% (1.304 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Gintung Energy GTEC-195G6S68 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-195G6S68 (195.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 31 | 6.04 kW | 435 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 42 | 8.19 kW | 590 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 52 | 10.14 kW | 730 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-195G6S68 architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Gintung Energy GTEC-195G6S68 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy GTEC-190G6S68** | 190.0 W | 170.4 W | 29.71 V | 23.61 V | 14.57% |
| **Gintung Energy GTEC-195G6S68** | 195.0 W | 175.0 W | 29.82 V | 23.67 V | 14.95% |

## How Many Gintung Energy GTEC-195G6S68 Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy GTEC-195G6S68 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=29.82V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 34.38 V | 17 panels | 584.5 V | 29 panels |
| **-10 C (14 F)** | 33.37 V | 17 panels | 567.3 V | 29 panels |
| **0 C (32 F)** | 32.35 V | 18 panels | 582.3 V | 30 panels |
| **25 C (77 F STC)** | 29.82 V | 20 panels | 596.4 V | 33 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-195G6S68?

Alternative CEC solar modules from competing brands near Gintung Energy GTEC-195G6S68 (195.0 W), including Shanghai ST Solar STP195-48.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Shanghai ST Solar STP195-48**](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stp195-48/) Shanghai ST Solar | 195.0 W | Tie (0 W) | 30.0 V | 14.58% | 89.6% |
| [**Lightway Green New Energy LW190(23)P1310x990**](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw190-23-p1310x990/) Lightway Green New Energy | 190.0 W | -5.0 W | 30.0 V | 14.8% | 89.6% |
| [**Mitsubishi Electric PV-UD190HA6**](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-ud190ha6/) Mitsubishi Electric | 190.0 W | -5.0 W | 30.5 V | 13.74% | 91.7% |
| [**Perfect Source Technology PST 188 3GP48**](https://epri-peac.com/solar-equipment/modules/perfect-source-technology/perfect-source-technology-pst-188-3gp48/) Perfect Source Technology | 188.0 W | -7.0 W | 30.0 V | 14.02% | 89.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-195G6S68?

Evaluate Gintung Energy GTEC-195G6S68 (195.0 W STC, 29.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-195G6S68 reaches 34.38 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 42 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (590 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-195G6S68 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy GTEC-195G6S68 8 kW Residential Fit

Needs 42 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Shanghai ST Solar STP195-48.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 175.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-195G6S68 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Gintung Energy GTEC-195G6S68 PTC wattage (175.0 W) lower than STC (195.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 175.0 W PTC (89.7% retention) across Gintung Energy GTEC-195G6S68's 1.304 m2 aperture.

### Who should skip Gintung Energy GTEC-195G6S68 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 42 Gintung Energy GTEC-195G6S68 panels (590 sq ft) leave unusable roof gaps vs. Shanghai ST Solar STP195-48.

### What is the 1,000 V commercial string limit for Gintung Energy GTEC-195G6S68?

On 1,000 V commercial inverters at -10 C (33.37 V cold Voc), Gintung Energy GTEC-195G6S68 fits up to 29 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy GTEC-195G6S68.

## Related Pages

Compare Gintung Energy equipment, Shanghai ST Solar STP195-48 specs, utility payback rates, and NEC string calculators alongside Gintung Energy GTEC-195G6S68.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)