title: "Gintung Energy GTEC-195G6M68 Specs (195.0W, 29.87V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-195g6m68/
description: "CEC datasheet for Gintung Energy GTEC-195G6M68: 195.0W STC, 29.87V Voc, 42-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy GTEC-195G6M68 — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy GTEC-195G6M68 is a 195.0 W STC (174.6 W PTC) Multi-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 14.95% efficiency, 29.87 V Voc at 25 C, and 33.32 V cold Voc at -10 C (18 panels max per 600 V string).

- **STC Wattage** : 195.0 W

- **PTC Wattage** : 174.6 W

- **Voc @ 25C** : 29.87 V

- **Efficiency** : 14.95%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy GTEC-195G6M68 Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy GTEC-195G6M68: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Across 1,407 Multi-c-Si listings from Gintung Energy and peers, Gintung Energy GTEC-195G6M68 stands 83.8 W below the 278.8 W Multi-c-Si median and typical 89.5% PTC-to-STC thermal output (174.6 W real-world rating). Sizing 6 kW (31 panels) to 10 kW (52 panels) yields $1,512-$2,538/yr in baseline US bill offset. Lower 29.87 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters.

## Where Does Gintung Energy GTEC-195G6M68 Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy GTEC-195G6M68 (195.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define Gintung Energy GTEC-195G6M68?

Dataset percentiles tracking Gintung Energy GTEC-195G6M68 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Do the Dataset Ranks Show for Gintung Energy GTEC-195G6M68?

Benchmark highlights for Gintung Energy GTEC-195G6M68 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #21,088 / 21,677

### 195.0 W STC · Higher Than 2.5%

195.0 W STC (-190.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,805

### 14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

### 18 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.32 V at -10 C (599.8 V string) and 34.31 V at -20 C (17 max).

 8 kW Reference Array

### 42 Panels = 8,190 W STC

Occupies 54.8 m2 (590 sq ft) producing 7,333 W PTC; NEC 690.8 OCPD floor is 13.23 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.87 * (1 + (-0.33/100) * (-10 - 25)) = 33.32 V | OCPD = 1.56 * 8.48 = 13.23 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-195G6M68: Voc=29.87 V, beta_Voc=-0.33%/C, Isc=8.48 A, STC=195.0 W, Area=1.304 m2.

**Result:** 18 panels max on 600 V (599.8 V); 42 panels for 8 kW (590 sq ft).

## What Are the Published CEC Specifications for Gintung Energy GTEC-195G6M68?

Official CEC datasheet figures for Gintung Energy GTEC-195G6M68 (Multi-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-195G6M68.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 195.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 174.6 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 29.87 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 23.9 V / 8.16 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.95% (1.304 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy GTEC-195G6M68 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy GTEC-195G6M68 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 31 | 6.04 kW | 435 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 42 | 8.19 kW | 590 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 52 | 10.14 kW | 730 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-195G6M68 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Gintung Energy GTEC-195G6M68 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy GTEC-190G6M68** | 190.0 W | 170.0 W | 29.81 V | 23.84 V | 14.57% |
| **Gintung Energy GTEC-195G6M68** | 195.0 W | 174.6 W | 29.87 V | 23.9 V | 14.95% |

## How Many Gintung Energy GTEC-195G6M68 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-195G6M68 (33.32 V at 14 F).

Computed from Voc=29.87V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 34.31 V | 17 panels | 583.3 V | 29 panels |
| **-10 C (14 F)** | 33.32 V | 18 panels | 599.8 V | 30 panels |
| **0 C (32 F)** | 32.33 V | 18 panels | 581.9 V | 30 panels |
| **25 C (77 F STC)** | 29.87 V | 20 panels | 597.4 V | 33 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-195G6M68?

Competing CEC solar panels closest to Gintung Energy GTEC-195G6M68 in nameplate wattage and Voc, starting with Shanghai ST Solar STP195-48.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Shanghai ST Solar STP195-48**](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stp195-48/) Shanghai ST Solar | 195.0 W | Tie (0 W) | 30.0 V | 14.58% | 89.6% |
| [**Lightway Green New Energy LW190(23)P1310x990**](https://epri-peac.com/solar-equipment/modules/lightway-green-new-energy/lightway-green-new-energy-lw190-23-p1310x990/) Lightway Green New Energy | 190.0 W | -5.0 W | 30.0 V | 14.8% | 89.6% |
| [**Mitsubishi Electric PV-UD190HA6**](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-ud190ha6/) Mitsubishi Electric | 190.0 W | -5.0 W | 30.5 V | 13.74% | 91.7% |
| [**Perfect Source Technology PST 188 3GP48**](https://epri-peac.com/solar-equipment/modules/perfect-source-technology/perfect-source-technology-pst-188-3gp48/) Perfect Source Technology | 188.0 W | -7.0 W | 30.0 V | 14.02% | 89.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-195G6M68?

Evaluate Gintung Energy GTEC-195G6M68 (195.0 W STC, 29.87 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-195G6M68 reaches 34.31 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 42 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (590 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-195G6M68 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy GTEC-195G6M68 8 kW Residential Fit

Needs 42 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Shanghai ST Solar STP195-48.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 174.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-195G6M68 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-195G6M68?

Multiplying Gintung Energy GTEC-195G6M68's 8.48 A short-circuit current by 1.56 equals 13.23 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Gintung Energy GTEC-195G6M68 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 33.32 V cold Voc at 14 F and handles 8.48 A Isc; string inverters cap Gintung Energy GTEC-195G6M68 at 18 panels on 600 V.

### Is Gintung Energy GTEC-195G6M68 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-195G6M68 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Gintung Energy equipment, Shanghai ST Solar STP195-48 specs, utility payback rates, and NEC string calculators alongside Gintung Energy GTEC-195G6M68.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)