# Gintung Energy ASEC-325G6M — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-325G6M is a 325.0 W STC (286.7 W PTC) Multi-c-Si solar module ranking #14,546 of 21,677 CEC listings (below all-CEC median; higher than 31.1% of peers). It delivers 16.62% efficiency, 45.35 V Voc at 25 C, and 50.79 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 325.0 W

- **PTC Wattage** : 286.7 W

- **Voc @ 25C** : 45.35 V

- **Efficiency** : 16.62%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-325G6M Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy ASEC-325G6M handles rooftop heat (286.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Gintung Energy ASEC-325G6M exhibits 9.38 A short-circuit current, requiring a 14.63 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #14,546 of 21,677 (46.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 48.9 m2 for an 8 kW system (31 panels for 10 kW). Mid-range 45.35 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Gintung Energy ASEC-325G6M Fall Across Listed CEC Models?

Where Gintung Energy ASEC-325G6M (325.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Gintung Energy ASEC-325G6M?

Percentile placement of Gintung Energy ASEC-325G6M across power density (166.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-325G6M?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy ASEC-325G6M specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #14,546 / 21,677

### 325.0 W STC · Higher Than 31.1%

325.0 W STC (-60.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,118

### 16.62% Aperture Efficiency

Power density 166.2 W/m2 (3.29 percentage points below 19.91% CEC median). PTC/STC ratio: 88.2% (rank #21,309).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.79 V at -10 C (558.7 V string) and 52.35 V at -20 C (11 max).

 8 kW Reference Array

### 25 Panels = 8,125 W STC

Occupies 48.9 m2 (526 sq ft) producing 7,168 W PTC; NEC 690.8 OCPD floor is 14.63 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.35 * (1 + (-0.343/100) * (-10 - 25)) = 50.79 V | OCPD = 1.56 * 9.38 = 14.63 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-325G6M: Voc=45.35 V, beta_Voc=-0.343%/C, Isc=9.38 A, STC=325.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (558.7 V); 25 panels for 8 kW (526 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-325G6M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy ASEC-325G6M.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-325G6M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 325.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 286.7 W (88.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.35 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.38 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.07 V / 9.01 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.62% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-325G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy ASEC-325G6M (325.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 19 | 6.17 kW | 400 sq ft | $1,544 | $2,611 |
| **8 kW Class** | 25 | 8.12 kW | 526 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 31 | 10.07 kW | 653 sq ft | $2,520 | $4,262 |

## How Many Gintung Energy ASEC-325G6M Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy ASEC-325G6M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.35V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.35 V | 11 panels | 575.9 V | 19 panels |
| **-10 C (14 F)** | 50.79 V | 11 panels | 558.7 V | 19 panels |
| **0 C (32 F)** | 49.24 V | 12 panels | 590.9 V | 20 panels |
| **25 C (77 F STC)** | 45.35 V | 13 panels | 589.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-325G6M?

Alternative CEC solar modules from competing brands near Gintung Energy ASEC-325G6M (325.0 W), including Flextronics FXS-325BB-MAB1W. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Flextronics FXS-325BB-MAB1W**](https://epri-peac.com/solar-equipment/modules/flextronics/flextronics-fxs-325bb-mab1w/) Flextronics | 325.0 W | Tie (0 W) | 45.8 V | 17.55% | 91.6% |
| [**Flextronics FXS-325BC-MAB1W**](https://epri-peac.com/solar-equipment/modules/flextronics/flextronics-fxs-325bc-mab1w/) Flextronics | 325.0 W | Tie (0 W) | 45.8 V | 17.55% | 91.6% |
| [**CertainTeed CT325P00-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct325p00-01/) CertainTeed | 325.0 W | Tie (0 W) | 45.9 V | 17.96% | 91.8% |
| [**Chinaland Solar Energy HSE325-72M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse325-72m/) Chinaland Solar Energy | 325.0 W | Tie (0 W) | 45.9 V | 16.84% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-325G6M?

Evaluate Gintung Energy ASEC-325G6M (325.0 W STC, 45.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-325G6M reaches 52.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (526 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-325G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-325G6M 8 kW Residential Fit

Needs 25 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Flextronics FXS-325BB-MAB1W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 286.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-325G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Gintung Energy ASEC-325G6M PTC wattage (286.7 W) lower than STC (325.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 286.7 W PTC (88.2% retention) across Gintung Energy ASEC-325G6M's 1.956 m2 aperture.

### Who should skip Gintung Energy ASEC-325G6M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 Gintung Energy ASEC-325G6M panels (526 sq ft) leave unusable roof gaps vs. Flextronics FXS-325BB-MAB1W.

### What is the 1,000 V commercial string limit for Gintung Energy ASEC-325G6M?

On 1,000 V commercial inverters at -10 C (50.79 V cold Voc), Gintung Energy ASEC-325G6M fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-325G6M.

## Related Pages

Compare Gintung Energy equipment, Flextronics FXS-325BB-MAB1W specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-325G6M.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)
- [Gintung Energy ASEC-310G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6s/)