# Gintung Energy ASEC-310G6M — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-310G6M is a 310.0 W STC (273.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.85% efficiency, 44.97 V Voc at 25 C, and 50.37 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 273.0 W

- **Voc @ 25C** : 44.97 V

- **Efficiency** : 15.85%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-310G6M Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy ASEC-310G6M: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Across 1,407 Multi-c-Si listings from Gintung Energy and peers, Gintung Energy ASEC-310G6M stands 31.2 W above the 278.8 W Multi-c-Si median and typical 88.1% PTC-to-STC thermal output (273.0 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 44.97 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Gintung Energy ASEC-310G6M Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy ASEC-310G6M (310.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define Gintung Energy ASEC-310G6M?

Dataset percentiles tracking Gintung Energy ASEC-310G6M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-310G6M?

Benchmark highlights for Gintung Energy ASEC-310G6M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,395

### 15.85% Aperture Efficiency

Power density 158.5 W/m2 (4.06 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.37 V at -10 C (554.1 V string) and 51.91 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.9 m2 (547 sq ft) producing 7,098 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.97 * (1 + (-0.343/100) * (-10 - 25)) = 50.37 V | OCPD = 1.56 * 9.05 = 14.12 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-310G6M: Voc=44.97 V, beta_Voc=-0.343%/C, Isc=9.05 A, STC=310.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (554.1 V); 26 panels for 8 kW (547 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-310G6M?

Official CEC datasheet figures for Gintung Energy ASEC-310G6M (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-310G6M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 273.0 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.97 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.76 V / 8.67 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.85% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-310G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy ASEC-310G6M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 421 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 547 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 695 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy ASEC-310G6M mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Gintung Energy ASEC-310G6M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy ASEC-300G6M** | 300.0 W | 263.9 W | 44.78 V | 35.5 V | 15.34% |
| **Gintung Energy ASEC-305G6M** | 305.0 W | 268.5 W | 44.88 V | 35.59 V | 15.59% |
| **Gintung Energy ASEC-310G6M** | 310.0 W | 273.0 W | 44.97 V | 35.76 V | 15.85% |
| **Gintung Energy ASEC-315G6M** | 315.0 W | 277.6 W | 45.09 V | 35.88 V | 16.1% |
| **Gintung Energy ASEC-320G6M** | 320.0 W | 282.1 W | 45.18 V | 35.96 V | 16.36% |

## How Many Gintung Energy ASEC-310G6M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy ASEC-310G6M (50.37 V at 14 F).

Computed from Voc=44.97V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.91 V | 11 panels | 571.0 V | 19 panels |
| **-10 C (14 F)** | 50.37 V | 11 panels | 554.1 V | 19 panels |
| **0 C (32 F)** | 48.83 V | 12 panels | 586.0 V | 20 panels |
| **25 C (77 F STC)** | 44.97 V | 13 panels | 584.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-310G6M?

Competing CEC solar panels closest to Gintung Energy ASEC-310G6M in nameplate wattage and Voc, starting with Auxin Solar AXN6M612T310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN6M612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t310/) Auxin Solar | 310.0 W | Tie (0 W) | 45.0 V | 15.89% | 89.4% |
| [**CSI Solar Co Ltd CS6X-310P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6x-310p/) CSI Solar Co Ltd | 310.0 W | Tie (0 W) | 44.9 V | 16.31% | 91.4% |
| [**AXITEC AC-310P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-310p-156-72s/) AXITEC | 310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |
| [**Centrosolar America DP72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-310/) Centrosolar America | 310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-310G6M?

Evaluate Gintung Energy ASEC-310G6M (310.0 W STC, 44.97 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-310G6M reaches 51.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-310G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-310G6M 8 kW Residential Fit

Needs 26 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 273.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-310G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Gintung Energy ASEC-310G6M?

Multiplying Gintung Energy ASEC-310G6M's 9.05 A short-circuit current by 1.56 equals 14.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Gintung Energy ASEC-310G6M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.37 V cold Voc at 14 F and handles 9.05 A Isc; string inverters cap Gintung Energy ASEC-310G6M at 11 panels on 600 V.

### Is Gintung Energy ASEC-310G6M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy ASEC-310G6M rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare Gintung Energy equipment, Auxin Solar AXN6M612T310 specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-310G6M.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6s/)