title: "Gintung Energy ASEC-260G6M6B Specs (260.0W, 41.21V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6m6b/
description: "CEC datasheet for Gintung Energy ASEC-260G6M6B: 260.0W STC, 41.21V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy ASEC-260G6M6B — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-260G6M6B is a 260.0 W STC (228.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 14.66% efficiency, 41.21 V Voc at 25 C, and 46.16 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 228.4 W

- **Voc @ 25C** : 41.21 V

- **Efficiency** : 14.66%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-260G6M6B Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy ASEC-260G6M6B: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Measured at 260.0 W STC and 228.4 W PTC, Gintung Energy ASEC-260G6M6B sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 146.6 W/m2 (5.25 percentage points below 19.91% CEC median). Mid-range 41.21 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 21 panels in series. Alternative peer Anhui Rinengzhongtian Semiconductor Development QJP265-72 rates 265.0 W.

## Where Does Gintung Energy ASEC-260G6M6B Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy ASEC-260G6M6B (260.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Dataset Percentiles Define Gintung Energy ASEC-260G6M6B?

Dataset percentiles tracking Gintung Energy ASEC-260G6M6B power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-260G6M6B?

Benchmark highlights for Gintung Energy ASEC-260G6M6B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,225

### 14.66% Aperture Efficiency

Power density 146.6 W/m2 (5.25 percentage points below 19.91% CEC median). PTC/STC ratio: 87.8% (rank #21,465).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.16 V at -10 C (553.9 V string) and 47.57 V at -20 C (12 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 55.0 m2 (592 sq ft) producing 7,080 W PTC; NEC 690.8 OCPD floor is 13.23 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.21 * (1 + (-0.343/100) * (-10 - 25)) = 46.16 V | OCPD = 1.56 * 8.48 = 13.23 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-260G6M6B: Voc=41.21 V, beta_Voc=-0.343%/C, Isc=8.48 A, STC=260.0 W, Area=1.773 m2.

**Result:** 12 panels max on 600 V (553.9 V); 31 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-260G6M6B?

Official CEC datasheet figures for Gintung Energy ASEC-260G6M6B (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-260G6M6B.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 228.4 W (87.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.21 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.34 V / 8.04 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.66% (1.773 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-260G6M6B Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy ASEC-260G6M6B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 458 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 592 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 744 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy ASEC-260G6M6B mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Gintung Energy ASEC-260G6M6B wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy ASEC-250G6M6B** | 250.0 W | 219.3 W | 40.95 V | 32.01 V | 14.1% |
| **Gintung Energy ASEC-255G6M6B** | 255.0 W | 223.9 W | 41.06 V | 32.16 V | 14.38% |
| **Gintung Energy ASEC-260G6M6B** | 260.0 W | 228.4 W | 41.21 V | 32.34 V | 14.66% |
| **Gintung Energy ASEC-265G6M6B** | 265.0 W | 232.9 W | 41.35 V | 32.64 V | 14.94% |
| **Gintung Energy ASEC-270G6M6B** | 270.0 W | 237.5 W | 41.44 V | 32.73 V | 15.23% |

## How Many Gintung Energy ASEC-260G6M6B Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy ASEC-260G6M6B (46.16 V at 14 F).

Computed from Voc=41.21V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 47.57 V | 12 panels | 570.8 V | 21 panels |
| **-10 C (14 F)** | 46.16 V | 12 panels | 553.9 V | 21 panels |
| **0 C (32 F)** | 44.74 V | 13 panels | 581.6 V | 22 panels |
| **25 C (77 F STC)** | 41.21 V | 14 panels | 576.9 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-260G6M6B?

Competing CEC solar panels closest to Gintung Energy ASEC-260G6M6B in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJP265-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJP265-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp265-72/) Anhui Rinengzhongtian Semiconductor Development | 265.0 W | +5.0 W | 42.3 V | 13.66% | 89.1% |
| [**BYD Company Limited BYD 260P6C-30**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-260p6c-30/) BYD Company Limited | 260.0 W | Tie (0 W) | 38.38 V | 15.98% | 90.4% |
| [**BYD Company Limited BYD260P6K-30**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd260p6k-30/) BYD Company Limited | 260.0 W | Tie (0 W) | 38.38 V | 15.95% | 91.7% |
| [**Centrosolar America DP60 260**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp60-260/) Centrosolar America | 260.0 W | Tie (0 W) | 38.28 V | 15.86% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-260G6M6B?

Evaluate Gintung Energy ASEC-260G6M6B (260.0 W STC, 41.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-260G6M6B reaches 47.57 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-260G6M6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-260G6M6B 8 kW Residential Fit

Needs 31 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP265-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 228.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-260G6M6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Gintung Energy ASEC-260G6M6B panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-260G6M6B cold Voc rises from 41.21 V to 46.16 V (beta_Voc -0.343%/C), capping a 600 V string at 12 panels (553.9 V).

### How much roof area does an 8 kW array of Gintung Energy ASEC-260G6M6B need?

An 8 kW DC system uses 31 Gintung Energy ASEC-260G6M6B modules (8,060 W STC / 7,080 W PTC), covering roughly 592 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does Gintung Energy ASEC-260G6M6B compare against Anhui Rinengzhongtian Semiconductor Development QJP265-72?

Gintung Energy ASEC-260G6M6B outputs 260.0 W STC (41.21 V Voc, rank #19,146 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJP265-72 delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Gintung Energy equipment, Anhui Rinengzhongtian Semiconductor Development QJP265-72 specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-260G6M6B.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)