---
title: "Gintung Energy ASEC-260G6M Specs (260.0W, 43.84V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6m/
description: "CEC datasheet for Gintung Energy ASEC-260G6M: 260.0W STC, 43.84V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Gintung Energy ASEC-260G6M — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-260G6M is a 260.0 W STC (232.1 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 13.29% efficiency, 43.84 V Voc at 25 C, and 48.9 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 232.1 W

- **Voc @ 25C** : 43.84 V

- **Efficiency** : 13.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-260G6M Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy ASEC-260G6M: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Measured at 260.0 W STC and 232.1 W PTC, Gintung Energy ASEC-260G6M sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 132.9 W/m2 (6.62 percentage points below 19.91% CEC median). Mid-range 43.84 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer CSI Solar Co Ltd CS6X-265P rates 265.0 W.

## Where Does Gintung Energy ASEC-260G6M Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy ASEC-260G6M (260.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define Gintung Energy ASEC-260G6M?

Dataset percentiles tracking Gintung Energy ASEC-260G6M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-260G6M?

Benchmark highlights for Gintung Energy ASEC-260G6M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,324

### 13.29% Aperture Efficiency

Power density 132.9 W/m2 (6.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.9 V at -10 C (586.8 V string) and 50.35 V at -20 C (11 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 60.6 m2 (653 sq ft) producing 7,195 W PTC; NEC 690.8 OCPD floor is 12.5 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.84 * (1 + (-0.33/100) * (-10 - 25)) = 48.9 V | OCPD = 1.56 * 8.01 = 12.5 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-260G6M: Voc=43.84 V, beta_Voc=-0.33%/C, Isc=8.01 A, STC=260.0 W, Area=1.956 m2.

**Result:** 12 panels max on 600 V (586.8 V); 31 panels for 8 kW (653 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-260G6M?

Official CEC datasheet figures for Gintung Energy ASEC-260G6M (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-260G6M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 232.1 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.84 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.01 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.53 V / 7.53 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.29% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-260G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy ASEC-260G6M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 505 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 653 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 821 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy ASEC-260G6M mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Gintung Energy ASEC-260G6M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy ASEC-250G6M** | 250.0 W | 223.0 W | 43.53 V | 34.3 V | 12.78% |
| **Gintung Energy ASEC-255G6M** | 255.0 W | 227.5 W | 43.69 V | 34.46 V | 13.04% |
| **Gintung Energy ASEC-260G6M** | 260.0 W | 232.1 W | 43.84 V | 34.53 V | 13.29% |
| **Gintung Energy ASEC-265G6M** | 265.0 W | 236.7 W | 43.99 V | 34.65 V | 13.55% |
| **Gintung Energy ASEC-270G6M** | 270.0 W | 241.3 W | 44.15 V | 34.87 V | 13.8% |

## How Many Gintung Energy ASEC-260G6M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy ASEC-260G6M (48.9 V at 14 F).

Computed from Voc=43.84V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.35 V | 11 panels | 553.9 V | 19 panels |
| **-10 C (14 F)** | 48.9 V | 12 panels | 586.8 V | 20 panels |
| **0 C (32 F)** | 47.46 V | 12 panels | 569.5 V | 21 panels |
| **25 C (77 F STC)** | 43.84 V | 13 panels | 569.9 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-260G6M?

Competing CEC solar panels closest to Gintung Energy ASEC-260G6M in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6X-265P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6X-265P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6x-265p/) CSI Solar Co Ltd | 265.0 W | +5.0 W | 43.9 V | 14.31% | 88.8% |
| [**Advance Power API-P265**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p265/) Advance Power | 265.0 W | +5.0 W | 43.27 V | 13.58% | 89.1% |
| [**Auxin Solar AXN6P610T265**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p610t265/) Auxin Solar | 265.0 W | +5.0 W | 43.27 V | 13.58% | 89.1% |
| [**BYD Company Limited BYD 265P6C-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-265p6c-36/) BYD Company Limited | 265.0 W | +5.0 W | 43.11 V | 13.66% | 90.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-260G6M?

Evaluate Gintung Energy ASEC-260G6M (260.0 W STC, 43.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-260G6M reaches 50.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 653 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (653 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-260G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-260G6M 8 kW Residential Fit

Needs 31 modules (653 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6X-265P.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-260G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Gintung Energy ASEC-260G6M panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-260G6M cold Voc rises from 43.84 V to 48.9 V (beta_Voc -0.33%/C), capping a 600 V string at 12 panels (586.8 V).

### How much roof area does an 8 kW array of Gintung Energy ASEC-260G6M need?

An 8 kW DC system uses 31 Gintung Energy ASEC-260G6M modules (8,060 W STC / 7,195 W PTC), covering roughly 653 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does Gintung Energy ASEC-260G6M compare against CSI Solar Co Ltd CS6X-265P?

Gintung Energy ASEC-260G6M outputs 260.0 W STC (43.84 V Voc, rank #19,146 of 21,677), while CSI Solar Co Ltd CS6X-265P delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Gintung Energy equipment, CSI Solar Co Ltd CS6X-265P specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-260G6M.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)
