title: "Gintung Energy ASEC-235G6S69 Specs (235.0W, 34.13V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6s69/
description: "CEC datasheet for Gintung Energy ASEC-235G6S69: 235.0W STC, 34.13V Voc, 35-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Gintung Energy ASEC-235G6S69 — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-235G6S69 is a 235.0 W STC (206.2 W PTC) Mono-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 16.04% efficiency, 34.13 V Voc at 25 C, and 38.23 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 235.0 W

- **PTC Wattage** : 206.2 W

- **Voc @ 25C** : 34.13 V

- **Efficiency** : 16.04%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-235G6S69 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-235G6S69 (Mono-c-Si) residential solar systems.

Homeowners evaluating Gintung Energy ASEC-235G6S69 need 26 panels for 6 kW or 35 panels (552 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (552 sq ft). Under NEC 690.7(A), beta_Voc (-0.343%/C) pushes open-circuit voltage to 38.23 V at 14 F and 39.4 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Gintung Energy ASEC-235G6S69 Fall Across Listed CEC Models?

Comparison of Gintung Energy ASEC-235G6S69 (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Dataset Percentiles Define Gintung Energy ASEC-235G6S69?

Relative ranking of Gintung Energy ASEC-235G6S69 across nameplate watts, 87.7% PTC thermal ratio, and module aperture efficiency. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-235G6S69?

Summary of Gintung Energy ASEC-235G6S69 output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.

Rank #20,368 / 21,677

### 235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,090

### 16.04% Aperture Efficiency

Power density 160.4 W/m2 (3.87 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.23 V at -10 C (573.4 V string) and 39.4 V at -20 C (15 max).

 8 kW Reference Array

### 35 Panels = 8,225 W STC

Occupies 51.3 m2 (552 sq ft) producing 7,217 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 34.13 * (1 + (-0.343/100) * (-10 - 25)) = 38.23 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-235G6S69: Voc=34.13 V, beta_Voc=-0.343%/C, Isc=9.0 A, STC=235.0 W, Area=1.465 m2.

**Result:** 15 panels max on 600 V (573.4 V); 35 panels for 8 kW (552 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-235G6S69?

Complete CEC test sheet for Gintung Energy ASEC-235G6S69 including Isc (9.0 A), Voc (34.13 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-235G6S69.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 206.2 W (87.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 34.13 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 27.17 V / 8.65 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.04% (1.465 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-235G6S69 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-235G6S69.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.11 kW | 410 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 35 | 8.22 kW | 552 sq ft | $2,057 | $3,479 |
| **10 kW Class** | 43 | 10.11 kW | 678 sq ft | $2,530 | $4,279 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Related Gintung Energy power steps and black/silver trims consolidated into this Gintung Energy ASEC-235G6S69 series guide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Gintung Energy ASEC-235G6S69 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy ASEC-225G6S69** | 225.0 W | 197.1 W | 33.92 V | 26.85 V | 15.36% |
| **Gintung Energy ASEC-230G6S69** | 230.0 W | 201.6 W | 34.08 V | 27.0 V | 15.7% |
| **Gintung Energy ASEC-235G6S69** | 235.0 W | 206.2 W | 34.13 V | 27.17 V | 16.04% |
| **Gintung Energy ASEC-240G6S69** | 240.0 W | 210.7 W | 34.19 V | 27.33 V | 16.39% |
| **Gintung Energy ASEC-245G6S69** | 245.0 W | 215.3 W | 34.29 V | 27.44 V | 16.73% |

## How Many Gintung Energy ASEC-235G6S69 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Gintung Energy ASEC-235G6S69 (34.13 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=34.13V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 39.4 V | 15 panels | 591.0 V | 25 panels |
| **-10 C (14 F)** | 38.23 V | 15 panels | 573.4 V | 26 panels |
| **0 C (32 F)** | 37.06 V | 16 panels | 593.0 V | 26 panels |
| **25 C (77 F STC)** | 34.13 V | 17 panels | 580.2 V | 29 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-235G6S69?

Four comparable CEC modules such as Centrosolar America DP54 230 (230.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DP54 230**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp54-230/) Centrosolar America | 230.0 W | -5.0 W | 34.02 V | 15.51% | 88.7% |
| [**Anhui Rinengzhongtian Semiconductor Development QJP235-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp235-60/) Anhui Rinengzhongtian Semiconductor Development | 235.0 W | Tie (0 W) | 36.1 V | 14.44% | 89.3% |
| [**Changzhou Nesl Solartech DJ-235P-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-235p-st15/) Changzhou Nesl Solartech | 235.0 W | Tie (0 W) | 36.2 V | 14.39% | 90.3% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM235-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm235-60/) Anhui Rinengzhongtian Semiconductor Development | 235.0 W | Tie (0 W) | 36.65 V | 14.44% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-235G6S69?

Evaluate Gintung Energy ASEC-235G6S69 (235.0 W STC, 34.13 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-235G6S69 reaches 39.4 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 552 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (552 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-235G6S69 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-235G6S69 8 kW Residential Fit

Needs 35 modules (552 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 230.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 206.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-235G6S69 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Gintung Energy ASEC-235G6S69 PTC wattage (206.2 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 206.2 W PTC (87.7% retention) across Gintung Energy ASEC-235G6S69's 1.465 m2 aperture.

### Who should skip Gintung Energy ASEC-235G6S69 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Gintung Energy ASEC-235G6S69 panels (552 sq ft) leave unusable roof gaps vs. Centrosolar America DP54 230.

### What is the 1,000 V commercial string limit for Gintung Energy ASEC-235G6S69?

On 1,000 V commercial inverters at -10 C (38.23 V cold Voc), Gintung Energy ASEC-235G6S69 fits up to 26 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-235G6S69.

## Related Pages

Compare Gintung Energy equipment, Centrosolar America DP54 230 specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-235G6S69.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)