title: "Gintung Energy ASEC-230G6M Specs (230.0W, 36.87V Voc)"
url: https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-230g6m/
description: "CEC datasheet for Gintung Energy ASEC-230G6M: 230.0W STC, 36.87V Voc, 35-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Gintung Energy ASEC-230G6M — CEC Solar Module Specifications

Manufacturer: [**Gintung Energy**](https://epri-peac.com/solar-equipment/brands/gintung-energy/) Registry: **CEC Verified Engineering Specification**

Gintung Energy ASEC-230G6M is a 230.0 W STC (205.7 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.28% efficiency, 36.87 V Voc at 25 C, and 41.13 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 230.0 W

- **PTC Wattage** : 205.7 W

- **Voc @ 25C** : 36.87 V

- **Efficiency** : 14.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Gintung Energy ASEC-230G6M Compare Against Peer CEC Listings?

Engineering position of Gintung Energy ASEC-230G6M (230.0 W STC) vs. Anji Dasol Solar Energy Science & Technology DS-A4-230 across 1,407 CEC Multi-c-Si solar modules.

Ranking #20,522 across 21,677 CEC solar panels (below all-CEC median; higher than 4.7% of peers), Gintung Energy ASEC-230G6M operates as a compact residential or specialty off-grid module sitting 48.8 W below the 278.8 W Multi-c-Si median. Lower 36.87 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.4% PTC-to-STC thermal output (205.7 W real-world rating), 35 panels occupy 607 sq ft and offset roughly $2,015/yr at average US rates (or $3,407/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Gintung Energy ASEC-230G6M Fall Across Listed CEC Models?

Plots Gintung Energy ASEC-230G6M at 230.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Gintung Energy ASEC-230G6M?

Benchmarks Gintung Energy ASEC-230G6M on STC wattage, thermal PTC/STC retention, and 14.28 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Gintung Energy ASEC-230G6M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-230G6M by Gintung Energy.

Rank #20,522 / 21,677

### 230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,643

### 14.28% Aperture Efficiency

Power density 142.8 W/m2 (5.63 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.13 V at -10 C (575.8 V string) and 42.35 V at -20 C (14 max).

 8 kW Reference Array

### 35 Panels = 8,050 W STC

Occupies 56.4 m2 (607 sq ft) producing 7,200 W PTC; NEC 690.8 OCPD floor is 12.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.87 * (1 + (-0.33/100) * (-10 - 25)) = 41.13 V | OCPD = 1.56 * 8.32 = 12.98 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-230G6M: Voc=36.87 V, beta_Voc=-0.33%/C, Isc=8.32 A, STC=230.0 W, Area=1.611 m2.

**Result:** 14 panels max on 600 V (575.8 V); 35 panels for 8 kW (607 sq ft).

## What Are the Published CEC Specifications for Gintung Energy ASEC-230G6M?

Laboratory test ratings recorded for Gintung Energy ASEC-230G6M (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-230G6M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 205.7 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.87 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.3 V / 7.85 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.28% (1.611 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Gintung Energy ASEC-230G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (607 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-230G6M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 27 | 6.21 kW | 468 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 35 | 8.05 kW | 607 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 44 | 10.12 kW | 763 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Sibling wattage bins and frame colors grouped with Gintung Energy ASEC-230G6M under Gintung Energy to prevent duplicate spec pages.

Sibling CEC listings grouped into the Gintung Energy ASEC-230G6M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Gintung Energy ASEC-225G6M** | 225.0 W | 201.1 W | 36.75 V | 29.19 V | 13.97% |
| **Gintung Energy ASEC-230G6M** | 230.0 W | 205.7 W | 36.87 V | 29.3 V | 14.28% |
| **Gintung Energy ASEC-235G6M** | 235.0 W | 210.3 W | 37.06 V | 29.34 V | 14.59% |

## How Many Gintung Energy ASEC-230G6M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Gintung Energy ASEC-230G6M (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.87V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.35 V | 14 panels | 592.9 V | 23 panels |
| **-10 C (14 F)** | 41.13 V | 14 panels | 575.8 V | 24 panels |
| **0 C (32 F)** | 39.91 V | 15 panels | 598.6 V | 25 panels |
| **25 C (77 F STC)** | 36.87 V | 16 panels | 589.9 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-230G6M?

Closest cross-brand CEC competitors to Gintung Energy ASEC-230G6M matched near 230.0 W STC and 36.87 V Voc, led by Anji Dasol Solar Energy Science & Technology DS-A4-230.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anji Dasol Solar Energy Science & Technology DS-A4-230**](https://epri-peac.com/solar-equipment/modules/anji-dasol-solar-energy-science-technology/anji-dasol-solar-energy-science-technology-ds-a4-230/) Anji Dasol Solar Energy Science & Technology | 230.0 W | Tie (0 W) | 36.9 V | 13.97% | 87.3% |
| [**Grape Solar GS-P-230-CS**](https://epri-peac.com/solar-equipment/modules/grape-solar/grape-solar-gs-p-230-cs/) Grape Solar | 230.0 W | Tie (0 W) | 36.8 V | 14.3% | 91.7% |
| [**Guangdong Golden Glass Technologies GG230M2-30/1640x992**](https://epri-peac.com/solar-equipment/modules/guangdong-golden-glass-technologies/guangdong-golden-glass-technologies-gg230m2-30-1640x992/) Guangdong Golden Glass Technologies | 230.0 W | Tie (0 W) | 37.0 V | 14.14% | 90.3% |
| [**APOS Energy AP230**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-ap230/) APOS Energy | 230.0 W | Tie (0 W) | 37.32 V | 13.86% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-230G6M?

Evaluate Gintung Energy ASEC-230G6M (230.0 W STC, 36.87 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-230G6M reaches 42.35 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 607 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-230G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Gintung Energy ASEC-230G6M 8 kW Residential Fit

Needs 35 modules (607 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anji Dasol Solar Energy Science & Technology DS-A4-230.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 205.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-230G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Gintung Energy ASEC-230G6M panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-230G6M cold Voc rises from 36.87 V to 41.13 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (575.8 V).

### How much roof area does an 8 kW array of Gintung Energy ASEC-230G6M need?

An 8 kW DC system uses 35 Gintung Energy ASEC-230G6M modules (8,050 W STC / 7,200 W PTC), covering roughly 607 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

### How does Gintung Energy ASEC-230G6M compare against Anji Dasol Solar Energy Science & Technology DS-A4-230?

Gintung Energy ASEC-230G6M outputs 230.0 W STC (36.87 V Voc, rank #20,522 of 21,677), while Anji Dasol Solar Energy Science & Technology DS-A4-230 delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Gintung Energy equipment, Anji Dasol Solar Energy Science & Technology DS-A4-230 specs, utility payback rates, and NEC string calculators alongside Gintung Energy ASEC-230G6M.

[All Gintung Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/gintung-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Gintung Energy

- [All Gintung Energy Specs](https://epri-peac.com/solar-equipment/brands/gintung-energy/)
- [Gintung Energy ASEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/)
- [Gintung Energy ASEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/)
- [Gintung Energy GTEC-325G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/)
- [Gintung Energy GTEC-325G6S](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/)
- [Gintung Energy ASEC-310G6M](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/)